COMPLIANCE INFO_2012-2017
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
C
>
CENTER
>
430
>
2300 - Underground Storage Tank Program
>
PR0231425
>
COMPLIANCE INFO_2012-2017
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/30/2020 3:36:41 PM
Creation date
6/23/2020 6:47:50 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2012-2017
RECORD_ID
PR0231425
PE
2361
FACILITY_ID
FA0003838
FACILITY_NAME
Frontier California Inc.: Manteca CO
STREET_NUMBER
430
Direction
W
STREET_NAME
CENTER
STREET_TYPE
St
City
Manteca
Zip
95336
APN
217-021-04
CURRENT_STATUS
01
SITE_LOCATION
430 W Center St
P_LOCATION
04
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231425_430 W CENTER_2012-2017.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
530
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
i <br /> t <br /> D. Results of Testing/Servicing <br /> .tet <br /> Software Version lnstatled: 16.5 <br /> Complete the following checklist: <br /> Q Yes 0 No" Is the audible alarm operational? <br /> Q Yes ® No' Is the visual alarm operational? <br /> ✓ Yes Na' Were all sensors visually inspected,functionally tested,and confirmed operational? <br /> ✓Z Yes ® No" Were all sensors installed at lowest point of secondary containment and positioned so that other equipment will not interfere with their <br /> roper operation? <br /> ✓�` Yes No' If alarms are relayed to a remote monitoring station,is all communications equipment(e.g.modem)operational? <br /> NIA <br /> Yes No" For pressurized piping systems, does the turbine automatically shut down if the piping secondary containment monitoring system <br /> 8 N/A detects a leak,fails to operate,or is electrically disconnected? If yes:which sensors initiate positive shut-down? (Check all that apply) <br /> []Sump/Trench Sensors:. []Dispenser Containment Sensors. Did you confirm positive shut-down due to leaks and sensor <br /> failure/disconnection? Yes;ONo. <br /> Yes ® No' For tank systems that utilize the monitoring system as the primary tank overfill warning device(i.e. no mechanical overfill prevention <br /> NA valve is installed),is the overfill warning alarm visible and audible at the tank fill point(s)and operating properly? If so,at what percent <br /> of tank capacity does the alarm trigger? 90 % <br /> ® Yes` ❑✓ No Was any monitoring equipment replaced? If yes, identify specific sensors, probes, or other equipment replaced and list the <br /> manufacturer name and model for all replacement parts in Section E,below. <br /> Yes' Fv7l No Was liquid found inside any secondary containment systems designed as dry systems? (Check all that apply)®Product;[]Water. If <br /> es,describe causes in Section E,below. <br /> ✓ Yes No' I Was monitoring system set-up reviewed to ensure proper settings?Attach set up reports,if applicable <br /> ✓ Yes No" Is all monitoring equipment operational per manufacturer's specifications? <br /> In Section E below,describe how and when these deficiencies were or will be corrected. <br /> E. Comments: <br /> Visual verification of overfill in drop tube done. <br /> Also tested and verified vault sensor ( 794380-320) good. <br /> Fuel polisher pan sensor attempted testing but unable to get alarm.. sensor is part of <br /> polisher. <br /> Monitoring System Certification Page 2 of 4 12107 <br /> ? <br /> 2/21/07 <br />