My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2012-2017
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
C
>
CENTER
>
430
>
2300 - Underground Storage Tank Program
>
PR0231425
>
COMPLIANCE INFO_2012-2017
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/30/2020 3:36:41 PM
Creation date
6/23/2020 6:47:50 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2012-2017
RECORD_ID
PR0231425
PE
2361
FACILITY_ID
FA0003838
FACILITY_NAME
Frontier California Inc.: Manteca CO
STREET_NUMBER
430
Direction
W
STREET_NAME
CENTER
STREET_TYPE
St
City
Manteca
Zip
95336
APN
217-021-04
CURRENT_STATUS
01
SITE_LOCATION
430 W Center St
P_LOCATION
04
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231425_430 W CENTER_2012-2017.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
530
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
AUG 5 2016 <br /> D. Results of Testing/Servicing <br /> Software Version Installed: 16.05 <br /> Complete the following checklist: <br /> ✓ Yes No' Is the audible alarm operational? <br /> Q Yes ® No' Is the visual alarm operational? <br /> ✓ Yes No' Were all sensors visually inspected,functionally tested,and confirmed operational? <br /> �✓ Yes 171 No' Were all sensors installed at lowest point of secondary containment and positioned so that other equipment will not interfere with their <br /> proper operation? <br /> Q Yes No` If alarms are relayed to a remote monitoring station,is all communications equipment(e.g.modem)operational? <br /> N/A <br /> Yes No- For pressurized piping systems, does the turbine automatically shut down if the piping secondary containment monitoring system <br /> e NIA detects a leak,tails to operate,or is electrically disconnected? If yes:which sensors initiate positive shut-down? (Check all that apply) <br /> ❑Sump/Trench Sensors: ❑Dispenser Containment Sensors. Did you confirm positive shut-down due to leaks and sensor <br /> failure/disconnection? Yes; No. <br /> Yes ® No' For tank systems that utilize the monitoring system as the primary tank overfill warning device(i.e. no mechanical overfill prevention <br /> N/A valve is installed),is the overfill warning alarm visible and audible at the tank till point(s)and operating properly? If so,at what percent <br /> of tank capacity does the alarm trigger? 90 % <br /> ❑ Yes' Q No Was any monitoring equipment replaced? If yes, identify specific sensors, probes, or other equipment replaced and list the <br /> manufacturer name and model for all replacement parts in Section E,below. <br /> ® Yes" Q No Was liquid found inside any secondary containment systems designed as dry systems? (Check all that apply)®Product; []Water. If <br /> es,describe causes in Section E,below. <br /> EYes No' Was monitoring system set-up reviewed to ensure proper settings?Attach set up reports,if applicable <br /> YNo" is ail monitoring equipment operational per manufacturer's specifications? <br /> AM- <br /> "In Section E below,describe how and when these deficiencies were or will be corrected. <br /> E. Comments: <br /> Made visual verification of overfill valve in drop tube. <br /> Also tested and verified vault sensor(794380-320 ) and polisher sensor(794380-320) <br /> All sensors tested good <br /> Monitoring System Certification Page 2 of 4 12107 <br /> 2 2/21/07 <br />
The URL can be used to link to this page
Your browser does not support the video tag.