COMPLIANCE INFO_2006-2011
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
L
>
LOUISE
>
1196
>
2300 - Underground Storage Tank Program
>
PR0231430
>
COMPLIANCE INFO_2006-2011
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/30/2024 11:04:03 AM
Creation date
6/23/2020 6:48:36 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2006-2011
RECORD_ID
PR0231430
PE
2361
FACILITY_ID
FA0000848
FACILITY_NAME
QUIK STOP MARKET #2121
STREET_NUMBER
1196
Direction
W
STREET_NAME
LOUISE
STREET_TYPE
AVE
City
MANTECA
Zip
95336
APN
217-410-43
CURRENT_STATUS
01
SITE_LOCATION
1196 W LOUISE AVE
P_LOCATION
04
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231430_1196 W LOUISE_2006-2011.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
320
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
UNDER DISPEAR CONTAINMENT (AC) TESTING <br />Test Method By: O Manufacturer • Industry Standard o Professional Engr o Other (see below) <br />Test Method Uses: O Pressure O vacuum • Hydrostatic o Other (see below) <br />Measuring Equipment Used: INCON TS -STS (Electronic Sump Test System) <br />Desr-rintinn Disn it 1/2 Disn # 3/4 Disn # 5/6 <br />UDC manufacturer <br />Bravo <br />Bravo <br />Bravo <br />UDC material <br />Steel <br />Steel <br />Steel <br />UDC depth (inches) <br />9 <br />9 <br />9 <br />Height from UDC bottom to highest <br />piping penetration <br />Bottom <br />Bottom <br />Bottom <br />Height from UDC bottom to lowest <br />electrical penetration <br />Bottom <br />Bottom <br />Bottom <br />Condition of UDC prior to testing <br />Dry <br />Dry <br />Dry <br />Portion of UDC tested <br />Entire <br />Entire <br />Entire <br />Type of shut -down present <br />Float <br />Float <br />Float <br />Was sensor removed for testing? <br />N/A <br />N/A <br />N/A <br />Was sensor properly replaced after testing? <br />N/A <br />N/A <br />N/A <br />Depth of water level from UDC bottom (in.) <br />6 <br />6 <br />6 <br />Wait time for water level to stabilize (hr:min) <br />0:05 <br />0:05 <br />0:05 <br />Test start time <br />9:11 AM <br />8:49 AM <br />8:49 AM <br />Initial Probe Reading <br />0.4916 <br />0.4969 <br />0.9994 <br />Test end time <br />9:27 AM <br />9:05 AM <br />9:05 AM <br />Final Probe Reading <br />0.4905 <br />0.4970 <br />0.9993 <br />Test duration (hr:min) <br />0:16 <br />0:16 <br />0:16 <br />Change in water level (± 0.0000 inches) <br />-0.0011 <br />0.0001 <br />-0.0001 <br />Pass/Fail threshold (±0.0020 inches / } Hr.) <br />0.0020 <br />0.0020 <br />0.0020 <br />TEST RESULT <br />PASS <br />PASS <br />PASS <br />Comments: <br />© 2006 Walton Engineering, Inc. <br />