My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_1998-2007
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
J
>
JACKSON
>
2501
>
2300 - Underground Storage Tank Program
>
PR0231488
>
COMPLIANCE INFO_1998-2007
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/12/2021 10:51:17 AM
Creation date
6/23/2020 6:49:22 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1998-2007
RECORD_ID
PR0231488
PE
2361
FACILITY_ID
FA0003910
FACILITY_NAME
H&M - BW #98
STREET_NUMBER
2501
STREET_NAME
JACKSON
STREET_TYPE
AVE
City
ESCALON
Zip
95320
CURRENT_STATUS
01
SITE_LOCATION
2501 JACKSON AVE
P_LOCATION
06
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231488_2501 JACKSON_1998-2007.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
460
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
-95 <br />UNIFIED PROGRAM CONSOLIDATED FORM <br />TANKS <br />UNDERGROUND STORAGE TANKS - TANK PAGE 1 <br />(two pages per tank) <br />Page of <br />TYPE OF ACTION ❑ l NEW SITE PERMIT ❑ 4 AMENDED PERMIT ❑ 5 CHANGE OF INFORMATION ❑ 6 TEMPORARY SITE CLOSURE <br />(Check one item only) ❑ 7 PERMANENTLY CLOSED ON SITE <br />3 RENEWAL PERMIT (Specify reason -for local on only) (Specify reason -for local use only) ❑ 8 TANK REMOVED 430 <br />BUSINESS NAME (Same as FACILITY NAME or DBA - Doing Business As) <br />FACILITY ID: <br />l <br />LOCA ION WITH 'SITE ( ional) 431 <br />,)SO/ �/� p <br />I. TANK DESCRIPTION (A scaled plot plan with the location of the UST system including buildings and landmarks shall be submitted to the local agency.) <br />TANK ID # 432 <br />TANK MANUFACTURER 433 <br />COMPARTMENTALIZED TANK El Yes C3 No 434 <br />/ .. <br />6 P -Al E, L_b 1 V <br />If"Yes", complete one page for each compartment. <br />DATE ALLED (YEAR/MO) 435 <br />TANK CAPACITY IN GALLONS 436 <br />NUMBER OF COMPARTMENTS 437 <br />OMk <br />( Z_ c) C) <br />ADDITIO AL DESCRIPTION (For local use only) 438 <br />II. TANK CONTENTS <br />TANK USE 439 <br />PETROLEUM TYPE 440 <br />;91. MOTOR VEHICLE FUEL <br />Q�.la. REGULAR UNLEADED ❑ 2. LEADED ❑ 5. JET FUEL <br />(If marked complete Petroleum Type) <br />❑ lb. PREMIUM UNLEADED ❑ 3. DIESEL ❑ 6. AVIATION FUEL <br />❑ 2. NON -FUEL PETROLEUM <br />❑ Ic. MIDGRADE UNLEADED ❑ 4. GASOHOL ❑ 99. OTHER <br />❑ 3. CHEMICAL PRODUCT <br />COMMON NAME (from Hazardous Materials Inventory page) 441 <br />CAS# (from Hazardous Materials Inventory page) 442 <br />❑ 4. HAZARDOUS WASTE <br />(Includes Used Oil) <br />`' <br />, 0L -t AV [ <br /><_,0 <br />UAj` 6,A <br />7 <br />❑ 95. UNKNOWN <br />III. TANK CONSTRUCTION <br />TYPE OF TANK 0 1. SINGLE WALL Ll 3. SINGLE WALL WITH 5. SINGLE WALL WITH INTERNAL BLADDER SYSTEM 443 <br />(Check one item only) EXTERIOR MEMBRANE LINER ❑ 95. UNKNOWN <br />P�2. DOUBLE WALL ❑ 4. SIGNLE WALL IN VAULT Cl 99. OTHER <br />TANK MATERIAL - primary tank 0 I. BARE STEEL 03. FIBERGLASS / PLASTIC 0 5. CONCRETE L1 95. UNKNOWN 444 <br />(Check one item only) ❑ 2. STAINLESS STEEL 4. STEEL CLAD W/FIBERGLASS ❑ 8. FRP COMPTIBLE W/100% METHANOL ❑ 99. OTHER <br />REINFORCED PLASTIC (FRP) <br />TANK MATERIAL - secondary tank L1 1. BARE STEEL 3. FIBERGLASS/ PLASTIC Ll 5. CONCRETE 0 95. UNKNOWN 445 <br />(Check one item only) ❑ 2. STAINLESS STEEL K4. STEEL CLAD W/FIBERGLASS ❑ 8. FRP COMPTIBLE W/100% METHANOL ❑ 99. OTHER <br />REINFORCED PLASTIC (FRP) ❑ 10. COATED STEEL <br />❑ 5. CONCRETE <br />TANK INTERIOR LINING 0 L RUBBER LINED U 3. EPDXY LINING 0 5. GLASS LINING 95. UNKNOWN 446 DATE INSTALLED 447 <br />OR COATING ❑ 2 ALKYD LINING ❑ 4 PHENOLIC LINING ❑ 6 UNLINED ❑ 99 OTHER <br />(Check one item only) (For local use only) <br />OTHER CORROSION ❑ 1 MANUFACTURED CATHODIC N3 FIBERGLASS REINFORCED PLASTIC ❑ 95 UNKNOWN 448 DATE INSTALLED 449 <br />PROTECTION IF APPLICABLE PROTECTION ❑ 4 IMPRESSED CURRENT ❑ 99 OTHER <br />(Check one item only) ❑ 2 SACRIFICIAL ANODE (For local use only) <br />SPILL AND OVERFILL YEAR INSTALLED 450 TYPE (local use only) 451 <br />OVERFILL PROTECTION EQUIPMENT: YEAR INSTALLED I �� 452 <br />(Check all that apply) 0 l SPILL CONTAINMENT j q `j <br />❑ 1 ALARM PO FILL TUBE SHUT OFF VALVE <br />K2 DROP TUBE <br />❑ 2 BALL FLOAT ❑ 4 EXEMPT <br />09J STRIKER PLATE <br />IV. TANK LEAK DETECTION (A description of the monitoring program shall be submitted to the local agency.) <br />IF SINGLE WALL TANK (Check all that apply) 453 <br />IF DOUBLE WALL TANK OR TANK WITH BLADDER 454 <br />(Check one item only) <br />❑ 1 VISUAL (EXPOSED PORTION ONLY) ❑ 5 MANUAL TANK GAUGING (MTG) <br />❑ l VISUAL (SINGLE WALL IN VAULT ONLY) <br />❑ 2 AUTOMATIC TANK GAUGING (ATG) ❑ 6 VADOSE ZONE <br />J, CONTINUOUS INTERSTITIAL MONITORING <br />❑ 3 CONTINUOUS ATG ❑ 7 GROUNDWATER <br />❑ 3 MANUAL MONITORING <br />❑ 4 STATISTICAL INVENTORY RECONCILIATION ❑ 8 TANK TESTING <br />(SIR) BIENNIAL TANK TESTING ❑ 99 OTHER <br />IV. TANK CLOSURE INFORMATION / PERMANENT CLOSURE IN PLACE <br />ESTIMATED DATE LAST USED (YR/MO/DAY) 455 <br />ESTIMATED QUANTITY OF SUBSTANCE REMAINING 456 <br />TANK FILLED WITH INERT MATERIAL? 457 <br />gallons <br />❑ Yes ❑ No <br />UPCF (12/99 revised) <br />10 <br />Formerly SWRCB Form B <br />
The URL can be used to link to this page
Your browser does not support the video tag.