My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2008-2012
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
J
>
JACKSON
>
2501
>
2300 - Underground Storage Tank Program
>
PR0231488
>
COMPLIANCE INFO_2008-2012
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/12/2021 11:12:52 AM
Creation date
6/23/2020 6:49:29 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2008-2012
RECORD_ID
PR0231488
PE
2361
FACILITY_ID
FA0003910
FACILITY_NAME
H&M - BW #98
STREET_NUMBER
2501
STREET_NAME
JACKSON
STREET_TYPE
AVE
City
ESCALON
Zip
95320
CURRENT_STATUS
01
SITE_LOCATION
2501 JACKSON AVE
P_LOCATION
06
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231488_2501 JACKSON_2008-2012.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
273
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
L <br /> Monitoring System Certification <br /> D. R"alts of Testing/Servicing <br /> Software Version Installed: 330.01 <br /> Com late the foliowin checklist- <br /> f0 Yes 0 No* 1 Is the audible alarm operational? <br /> 19 Yes El No* Is the visual alarm operational? <br /> 0 Yes E-1 No* Were all sensors visually inspected,functionally tested,and confirmed operational? <br /> (:Z Yes 0 No* Were all sensors installed at lowest point of secondary containment and positioned so that other equipment will <br /> not interfere with their proper operation? <br /> C3 Yes [3 No* If alarms are relayed to a remote monitoring station, is all communications equipment (e.g., modem) <br /> 0 N/A operational? <br /> I@ Yes 0 No* For pressurized piping systems, does the turbine automatically shut down if the piping secondary containment <br /> ❑ N/A monitoring system detects a leak,fails to operate,or is electrically disconnected? If yes:-which sensors initiate <br /> positive shut-down? (Check all that apply) M Sump/Trench Sensors; 0 Dispenser ConWnment Sensors. <br /> Did you confirm positive shut-down due to leaks and sensor failure/disconnection? 0 Yes; [3 No. <br /> 0 Yes 0 No* For tank systems that utilize the monitoring system as the primary tank overfill warning device (i.e., no <br /> 1Z N/A mechanical overfill prevention valve is installed), is the overfill warning alarm visible and audible at the tank <br /> fill point(s)and operating property? If so,at what percent of tank capacity does the alarm trigger? % <br /> 0 Yes* M No Was any monitoring equipment replaced? If yes, identify specific sensors,probes,or other equipment replaced <br /> -- and list the manufacturer name and model for all replacement parts in Section E,below. <br /> Yes* 0 No Was liquid found inside any secondary containment systems designed as dry systems? (Check all that apply) <br /> 13 Product; 0 Water. If yes,describe causes in Section B,below. <br /> NOes ff No* Was mon�"nn ssystemset-up reviewed to ensure proper settings?Attach set up reports,if ap licable <br /> lees, E3 No*Lis all monitoring equipment operational per manufacturer's specifications? <br /> *In Section E below,describe how and when these deficiencies were or will be corrected. <br /> E. CoMments: REMOVED 2112 GALLONS OF WATER OUT OF THE DIESEL STP SUMP. <br /> UN-036—316 wwwunidoe"rg Rev.01/17M <br />
The URL can be used to link to this page
Your browser does not support the video tag.