My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2008-2012
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
J
>
JACKSON
>
2501
>
2300 - Underground Storage Tank Program
>
PR0231488
>
COMPLIANCE INFO_2008-2012
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/12/2021 11:12:52 AM
Creation date
6/23/2020 6:49:29 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2008-2012
RECORD_ID
PR0231488
PE
2361
FACILITY_ID
FA0003910
FACILITY_NAME
H&M - BW #98
STREET_NUMBER
2501
STREET_NAME
JACKSON
STREET_TYPE
AVE
City
ESCALON
Zip
95320
CURRENT_STATUS
01
SITE_LOCATION
2501 JACKSON AVE
P_LOCATION
06
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231488_2501 JACKSON_2008-2012.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
273
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Power Supply <br />Circuit <br />Each distribution board contains its own power supply, a <br />Two -Wire current loop (M, an RS422 interface, and <br />eight dispenser loop drive circuits with auto -isolation. <br />Both of the input interfaces provide opto-coupled isolation <br />between the controller and the dispensers. The dispenser <br />loop drive is configured in a star drive and operates from <br />12VDC at 45ma for dispensers and CRINDs or 20ma for <br />G -CATs. <br />Each board has two separate isolated power supply <br />sections. One section is to provide voltage for the dis- <br />penser loop drivers (and associated logic) while the other <br />section provides the voltage to operate the RS422 inter- <br />face. Each section uses a separate winding on the second- <br />ary of the transformer. <br />The dispenser loop drivers are powered from the filtered, <br />but unregulated, 12VDC. The unregulated 12V may be <br />between +9 and +15 VDC because of AC line variations. <br />This unregulated 12VDC is also regulated down to +SVDC <br />for the loop driver logic. There are three test points pro- <br />vided: <br />TWI +12 (unregulated +12VDC) <br />TWI +5 (regulated +5VDC) <br />TWI GND (reference) <br />The RS -422 section is powered from the 10V secondary of <br />the transformer. The unregulated 10V may be between +7 <br />and +13VDC because of AC line variations. This voltage is <br />rectified and filtered to provide the input current for the <br />opto-couplers when the RS422 interface is used. This <br />filtered voltage is also regulated down to the +5VDC for the <br />RS422 driver. Once again, there are three test points <br />provided: <br />RS +10 (unregulated +1OVDC) <br />RS +5 (regulated +5VDC) <br />RS GND (reference) <br />NOTE: These supplies are isolated. You MUST use the <br />ground associated with the voltage test points to <br />obtain meaningful readings. <br />NOTE: If the distribution box has two distribution boards, <br />you will need to check the test points on both <br />boards to ensure that all required voltages are <br />present. <br />MDE-2714A • Universal Distribution Box Service Manual • 02196 Page 7 <br />
The URL can be used to link to this page
Your browser does not support the video tag.