Laserfiche WebLink
LINE LEAQDETECTOR (LLD) TEI& REPORT <br />TEST DATE: July 13, 2011 <br />Al. FACILITY <br />Name BW # 98 H & M Market <br />Address 2501 E. Jackson Avenue, Escalon, CA 95320 <br />Phone # 209-838-3971 <br />Contact Rohda Henry <br />A2. OWNER <br />Name Boyett Petroleum <br />Address 601 McHenry Avenue, Modesto, CA 95350 <br />Phone # 209-577-6000 <br />Contact Rohda Henry <br />A3. C U P A <br />A4. TESTING CONTRACTOR <br />Name <br />San Joaquin County Environmental Health <br />Name <br />Walton Engineering, Inc. <br />Address <br />600 E. Main Street, Stockton, CA 95202 <br />Address <br />P.O. Box 1025, W. Sacramento, CA 95691 <br />Notified <br />June 29, 2011 <br />Lic # <br />617238 A, B, Haz <br />Inspector <br />Muniappa Naidu <br />Contact <br />Dulcinea Covan <br />Phone # <br />209-468-8257 <br />Phone # <br />916-373-1166 <br />MECHANICAL LINE LEAK DETECTOR TEST RESULTS <br />Test Equipment Used: Vaporless VMI LDT-890 <br />2 3 <br />Gasoline - 91 Diesel <br />MLLD MLLD <br />VMI 99LD-2000 Red Jacket FX <br />1041298 9166 <br />28 12 <br />45 50 <br />3.00 3.00 <br />29 31 <br />18 9 <br />11 22 <br />30 30 <br />2 1 <br />PASS PASS <br />Tank number <br />Product contained Gasoline - 87 <br />Leak Detector Type MLLD <br />Leak detector make/model Red Jacket FX <br />Serial number 1025 <br />Functional Element Holding (psi) 13 <br />Resiliency (ml) 55 <br />Test leak rate (gph) 3.00 <br />Pump pressure (psi) 28 <br />Metering pressure (psi) 10 <br />Pressure Restriction Reduction (psi) 18 <br />Length of Restriction Test (seconds) 30 <br />Full Flow Opening time (seconds) 3 <br />TEST RESULT <br />Tank number <br />Product contained <br />Leak Detector Type <br />Leak detector make/model <br />Serial number <br />Functional Element Holding (psi) <br />Resiliency (ml) <br />Test leak rate (gph) <br />Pump pressure (psi) <br />Metering pressure (psi) <br />Pressure Restriction Reduction (psi) <br />Length of Restriction Test (seconds) <br />Full Flow Opening time (seconds) <br />TEST RESULT <br />J. COMMENTS: <br />Signature: a1�' 01 <br />11 E <br />1 <br />PASS <br />NGtUlEEe�9�l �:; 9NC. <br />Technician: Jessie Wadkins / 635397 5307886 -UT Date: July 13, 2011 <br />n n_ meson_ , nc. <br />Tank number <br />Product contained Gasoline - 87 <br />Leak Detector Type MLLD <br />Leak detector make/model Red Jacket FX <br />Serial number 1025 <br />Functional Element Holding (psi) 13 <br />Resiliency (ml) 55 <br />Test leak rate (gph) 3.00 <br />Pump pressure (psi) 28 <br />Metering pressure (psi) 10 <br />Pressure Restriction Reduction (psi) 18 <br />Length of Restriction Test (seconds) 30 <br />Full Flow Opening time (seconds) 3 <br />TEST RESULT <br />Tank number <br />Product contained <br />Leak Detector Type <br />Leak detector make/model <br />Serial number <br />Functional Element Holding (psi) <br />Resiliency (ml) <br />Test leak rate (gph) <br />Pump pressure (psi) <br />Metering pressure (psi) <br />Pressure Restriction Reduction (psi) <br />Length of Restriction Test (seconds) <br />Full Flow Opening time (seconds) <br />TEST RESULT <br />J. COMMENTS: <br />Signature: a1�' 01 <br />11 E <br />1 <br />PASS <br />NGtUlEEe�9�l �:; 9NC. <br />Technician: Jessie Wadkins / 635397 5307886 -UT Date: July 13, 2011 <br />n n_ meson_ , nc. <br />