My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2008-2012
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
J
>
JACKSON
>
2501
>
2300 - Underground Storage Tank Program
>
PR0231488
>
COMPLIANCE INFO_2008-2012
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/12/2021 11:12:52 AM
Creation date
6/23/2020 6:49:29 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2008-2012
RECORD_ID
PR0231488
PE
2361
FACILITY_ID
FA0003910
FACILITY_NAME
H&M - BW #98
STREET_NUMBER
2501
STREET_NAME
JACKSON
STREET_TYPE
AVE
City
ESCALON
Zip
95320
CURRENT_STATUS
01
SITE_LOCATION
2501 JACKSON AVE
P_LOCATION
06
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231488_2501 JACKSON_2008-2012.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
273
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
0 SAN JOAQUIN COUNTY . <br />ENVIRONMENTAL HEALTH DEPARTMENT <br />600 East Main Street, Stockton, California 95202-3029 <br />Telephone: (209) 468-3420 Fax: (209) 468-3433 Web: www.sigov.o[g/ehd/unitiii.html <br />CONTINUATION FORM <br />Page: 3 of 4 <br />OFFICIAL INSPECTION REPORT <br />Date: 07/13/11 <br />Facility Address: 2501 Jackson Road, Escalon <br />Program: UST <br />SUMMARY OF VIOLATIONS <br />CLASS I, CLASS II, or MINOR -Notice to Com <br />Notice to Comply <br />3. UST facility form on file with the EHD are not current and lacking the tank form. Any change of <br />information on these forms must be submitted to the EHD within 30 days of the changes. Immediately <br />complete and submit a copy of the facility and tank forms to the EHD within 30 days of receiving this <br />report. Complete a separate tank form for each tank. <br />3. UST facility form BOE number is incorrect. Immediately complete and submit a copy of the facility <br />form to the EHD within 30 days of receiving this report. <br />6. Current approved copy of the monitoring plan was not found on site. Copy of this plan shall be <br />retained on site at all times. Immediately locate and retain a copy on site. <br />21. Liquid was observed in the 87, 91, and diesel turbine sumps. If water could enter into the <br />secondary containment by precipitation or infiltration, it must be removed and disposed of properly. <br />Immediately remove this liquid, make a hazardous waste determination per Title 22 hazardous waste <br />regulations, and manage it accordingly. Ensure that the87, 91, and diesel sumps are maintained free of <br />liquid. The sumps were cleaned by the technician and the waste generated was put in the facility's <br />hazardous waste drum. <br />23c. The designated operator failed to check and note the correct test dates for the secondary <br />containment test date on 7/13/11 designated operator monthly inspection report. The correct test date is <br />6/9/11 instead of 6/9/08. During the monthly inspection, the designated operator shall check that all <br />required testing and maintenance for the UST system have been completed and document the dates <br />they were done. Ensure that designated operators performing monthly inspections at this facility are <br />including all of the required information on the reports. <br />14. A fuel leak was found at the test port on the shear valve of the 91 product line. All primary <br />containment must be product tight. Immediately discontinue use of failed piping and have a properly <br />licensed, trained, and certified contractor replace or repair the failed piping under permit and inspection <br />of the EHD. If the failed component can't be replaced immediately, there is a possibility that the 91 UST <br />system may be red tagged to prevent fuel inputs. <br />ALL EHD STAFF TIME ASSOCIATED WITH FAILING TO COMPLY BY THE ABOVE NOTED DATES WILL BE BILLED AT THE CURRENT HOURLY RATE ($115). <br />THIS FACILITY IS SUBJECT TO REINSPECTION AT ANY TIME AT EHD'S CURRENT HOURLY RATE. <br />EHD Inspector: I <br />110 / V19-'01, <br />Received By: <br />Title: <br />>� <br />EHD 23-02-003 Rev 06/01/10 CONTINUATION FORM <br />
The URL can be used to link to this page
Your browser does not support the video tag.