My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2008-2012
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
J
>
JACKSON
>
2501
>
2300 - Underground Storage Tank Program
>
PR0231488
>
COMPLIANCE INFO_2008-2012
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/12/2021 11:12:52 AM
Creation date
6/23/2020 6:49:29 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2008-2012
RECORD_ID
PR0231488
PE
2361
FACILITY_ID
FA0003910
FACILITY_NAME
H&M - BW #98
STREET_NUMBER
2501
STREET_NAME
JACKSON
STREET_TYPE
AVE
City
ESCALON
Zip
95320
CURRENT_STATUS
01
SITE_LOCATION
2501 JACKSON AVE
P_LOCATION
06
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231488_2501 JACKSON_2008-2012.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
273
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
D. Results of Testing/Servicing <br />Software. Version installed: •�� <br />Complete the following checklist: <br />0 Yes ❑ No* <br />Is the audible alarm rational? <br />,i"Yes ❑ No* <br />Is the visual alarm o rational? <br />,ErYes ❑ No* <br />Were all sensors' fiuictionali test and co o uonal? <br />:"Ycs 0 No* <br />Were all sensors installed at lowest point of secondary containment and positioned so that other equipment <br />will. not interfere with their WZr o "on? <br />Or—Yes ❑ No* <br />If alarms are relayed to a remote monitoring station, is all communications equipment (e.g. modern) <br />❑ N/A <br />operational? <br />,0- Yes ❑ No* <br />For pressurized piping systems, does the turbine automatically shut dowry if the piping secondary containment <br />❑ N/A <br />monitoring system detects a leak, fails to opera , or is electrically disconnected? If yes: which sensors initiate <br />that Sump/Trench Sensors; ❑ Dispenser <br />positive shutdown? (Check all apply) o ent Sensors. <br />Did you confirm positive shut own. due to leaks Hid sensor failure/disconnection? J9 Yes; ❑ No. <br />❑ Yes ❑ No* <br />For tante system that utilize the monitoring system as the primary tants overfill warning device (Le. no <br />)a N/A <br />mechanical overla�.i prevention valve is installed), is the overall warning alarm visible and audible at the tank <br />fills and ? If so at what Inrceut of tank 2MEk does the alarm tri er7 % <br />❑ Yes* P -No <br />Was any monitoring equipment replaced? If yes, identify specific sensors, probes, or other equipment replaced <br />and list the manufacturer name and model for all lacement larts in Section E below. <br />❑ Yes* 2r No <br />Was liquid found inside any secondary containment systems designed as dry systems? (Check all that apply) <br />❑ Product ❑ Water. If Yes, describe causes in Section E below. <br />❑ No* <br />Was monito ' stemset mvie+wed to ensure seta s? Attach set if a cable <br />EYWY❑ No* <br />is all monitofim eguipmento rational R2r cturer's s cifications? <br />to .1seenon t+; below, desenne now and when tnese dMcieneses were or will be co <br />L Comments: <br />F. in -Tank Gnuoina / S R FAninmeint: 0 C'herk this hex iftnok aa)voino sc rticed nn1v for hwantory mntml <br />
The URL can be used to link to this page
Your browser does not support the video tag.