Laserfiche WebLink
0 <br /> Environmental Health Department <br /> MAHON <br /> jA" <br /> COLJNTY <br /> h <br /> W ref, ep <br /> , <br /> 4W, <br /> Facility Name: Facility Phone: Date: <br /> H&M-BV\/#98 (209)838-3971 July 31,2018 <br /> Facility Address: CERS ID: <br /> 2501 JACKSON AVE, ESCALON, CA 95320 10181511 <br /> Inspection Contact: Title: Phone: <br /> Monica Farhat Environmental (209)- <br /> Inspection Type: Program: <br /> ROUTINE INSPECTION-Operating Permit 12361 -LIST FACILITY <br /> Consent For: Tc—.n—.ent Given By: <br /> X Inspection ED Photos El Samples Monica Farhat, Environmental <br /> Service Technician Onsite: Exp.Date: Designated Operator: Exp.Date: <br /> Randy Wilkerson 04/06/2019 Karen Arnaiz 03/30/2019 <br /> Service Technician Manufacturers Training: <br /> VR, 03/19/19-, VMI, 02/28/19 <br /> CCR=California Code of Regulations HSC=Health and Safety Code CFR=Code of Federal Regulations <br /> V=Violation R=Repeat violation COS Corrected on site during inspection <br /> F <br /> '40 <br /> 20 <br /> 7T <br /> 101 HSC 25284 Failure to obtain a valid permit to operate from the EHD including but not limited to unpaid fees o V o R o COS <br /> 102 HSC 25284(a)(3)(A)/(B) No written agreement between tank owner and tank operator to monitor the tank system ci V o R o COS <br /> 103 HSC 25292.2,25299.30 Current financial responsibility documents not submitted o V ii R Ei COS <br /> 104 CCR 2711 UST operating permit application for facility and tank information not submitted or current a V m R o COS <br /> 105 CCR 2632(d)(1), Failed to have an approved UST monitoring plan o V o R o COS <br /> 2634(d) <br /> 106 CCR 2632(d)(2), Failed to have an approved UST response plan o V ii R o COS <br /> 2634(e) <br /> 107 CCR 2632(d)(1)(C) Plot plan/site map not submitted or failed to completely show where monitoring is performed o V c R o COS <br /> 108 CCR 2637(f),2638(e) Failed to notify the EHD 48 hours prior to conducting testing o V o R c COS <br /> 109 CCR 2637 Failed to test secondary containment o V c R c COS <br /> 110 CCR 2637(e) Failed to submit secondary containment test report within 30 days o V o R o COS <br /> Ill CCR 2638(a) Failed to test monitoring and leak detection equipment annually Ei V o R n COS <br /> 112 HSC 25284.2 Failed to test spill containers annually [i V o R o COS <br /> 113 CCR 2638(d) Failed to submit monitoring system certification test report within 30 days o V o R o COS <br /> 114 CCR 2636(f) Failed to perform 0.1 gph annual line test for pressurized piping without fail safe or shut down ri V Ei R o COS <br /> 115 CCR 2715(a) Failed to submit to EHD notification of designated operator identification or change w/in 30 days Ei V o R o COS <br /> 116 CCR 2715 Designated operator,service tech or installer did not possess current ICC certification o V c R o COS <br /> 117 CCR 2663(h) Failed to inspect a lined or repaired steel tank within 10 years of lining and every 5 years after o V o R o COS <br /> 118 CCR 2663 Failed to submit tank lining certification within 30 days or to conduct proper tests o V o R c COS <br /> 119 HSC 25299(a)(8), Documents were falsified or misrepresented Ei V o R o COS <br /> 125299(b)(7) I <br /> 120 CCR 2635(d) Failed to submit UST Certification of Installation/Modification ii V o R o COS <br /> 121 CCR 2712(f) Failed to submit a written response within 30 days of receiving an inspection report n V o R o COS <br /> 122 CCR 26310) Failure to submit and maintain UST system component statement of compatibility for substance stored c V o R o COS <br /> --N"I <br /> W <br /> 201 <br /> CCR 2712(b) Failure to maintain monitoring,maintenance,and follow up action records o V c R o COS <br /> FA0003910 PR0231488 SCO01 07/31/2018 <br /> EHD 23-01 Rev.10/31/2017 Page 1 of 5 Underground Storage Tank Program OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />