My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2013-2018
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
J
>
JACKSON
>
2501
>
2300 - Underground Storage Tank Program
>
PR0231488
>
COMPLIANCE INFO_2013-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/12/2021 12:06:22 PM
Creation date
6/23/2020 6:49:38 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2013-2018
RECORD_ID
PR0231488
PE
2361
FACILITY_ID
FA0003910
FACILITY_NAME
H&M - BW #98
STREET_NUMBER
2501
STREET_NAME
JACKSON
STREET_TYPE
AVE
City
ESCALON
Zip
95320
CURRENT_STATUS
01
SITE_LOCATION
2501 JACKSON AVE
P_LOCATION
06
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231488_2501 JACKSON_2013-2018.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
516
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
MON]WRING SYSTEM CERTIFOATION <br /> For Use By All Jurisdictions Within the State of California <br /> Authority Cited.--Chapter 6.7,Health and Safety Code;Chapter 16,Division 3, Title 23, California Code of Regulations <br /> This form must be used to document testing and servicing of monitoring equipment. <br /> +A separate certification or report must be prepared far each monitoring system control panel by the technician who performs the work. <br /> A copy of this form must be provided to the tank system owner/operator. The owner/operator must submit a copy of this form to the local agency <br /> regulating UST systems within 30 days of test date. 1H.-ItFue-i-efis L -k of this page. <br /> A. General Information <br /> Facility Name: H &M KWIK SERVE B 9 Bldg.No.: <br /> Site Address: 2501 E.JACKSON City: MODESTO Zip: 95320 <br /> Facility Contact Person: MIKE Contact Phone No.: (209) 838-3971 <br /> Make/Model of Monitoring System: VEEDER ROOT TLS-350 Date of Testing/Servicing: 8/30/2017 <br /> B. Inventory of Equipment Tested/Certified <br /> Check thea ro riate boxes to indicates ecific!Sulpment inspected/servic-- <br /> Tank ID: 87 Tank ID: 91 <br /> 0 In-Tank Gauging Probe. Model: VEEDER ROOT [I In-Tank Gauging Probe. Model: VEEDER ROOT <br /> Annular Space or Vault Sensor. Model: 420 ED Annular Space or Vault Sensor. Model: 420/SPLIT <br /> Piping Sump/Trench Sensor(s). Model: 208 Piping Sump/Trench Sensor(s). Model: 208 <br /> 0 Fill Sump Sensor(s). Model: ❑Fill Sump Sensor(s). Model: <br /> ED Mechanical Line Leak Detector. Model: RED JACKET Mechanical Line Leak Detector. Model: RED JACKET <br /> C]Electronic Line Leak Detector. Model: ❑Electronic Line Leak Detector. Model: <br /> Tank Overfill/High-Level Sensor, Model: VEEDER ROOT Tank Overfill 11 High-Level Sensor. Model: VEEDER ROOT <br /> ❑Other(specify equipment type and model in Section E on Page 2). 0 Other(specify equipment type and model in Section E on Page 2). <br /> Tank ID: DIESEL Tank ID: <br /> 0 In-Tank Gauging Probe. Model: VEEDER ROOT El In-Tank Gauging Probe. Model: <br /> 0 Annular Space or Vault Sensor. Model: 420 El Annular Space or Vault Sensor. Model: <br /> 0 Piping Sump/Trench Sensoi(s). Model: 208 Fl Piping Sump/Trench Sensor(s). Model: <br /> F-1 Fill Sump Sensor(s). Model: [I Fill Sump Sensoqs). Model: <br /> 0 Mechanical Line Leak Detector. Model: RED JACKET ❑Mechanical Line Leak Detector. Model: <br /> El Electronic Line Leak Detector. Model: ❑Electronic Line Leak Detector. Model: <br /> Tank Overfill/High-Level Sensor. Model: VEEDER ROOT ❑Tank Overfill/High-Level Sensor. Model: <br /> ❑Other(specify equipment type and model in Section E on Page 2). C1 Other(specify equipment type and model in Section E on Page 2). <br /> Dispenser ID: 1/2 Dispenser ID: 314 <br /> []Dispenser Containment Sensor(s). Model: ❑Dispenser Containment Sensor(s). Model: <br /> Shear Valve(s). Shear Valve(s). <br /> Dispenser Containment Float(s)and Chain(s). Dispenser Containment Float(s)and Chain(s). <br /> Dispenser ID: Dispenser ID: <br /> El Dispenser Containment Sensor(s). Model: ❑Dispenser Containment Sensor(s). Model: <br /> El Shear Valve(s). ❑Shear Valve(s). <br /> ❑Dispenser Containment Float(s)and Chain(s). El Dispenser Containment Float(s)and Chain(s). <br /> Dispenser ID: Dispenser ID: <br /> 0 Dispenser Containment Sensor(s). Model: El Dispenser Containment Sensor(s). Model: <br /> ❑Shear Valve(s). E]Shear Valve(s). <br /> ❑Dispenser Containment Float(s)and Chain(s). El Dispenser Containment Float(s)and Chain(s). <br /> - - ii- <br /> *If the facility contains more tanks or dispensers,copy this form. Include information n-nation for every tank and dispenser at the facility. <br /> C. Certification -I certify that the equipment identified in this document was inspected/serviced in accordance with the manufacturers' <br /> guidelines. Attached to this Certification is information (e.g. manufacturers' checklists) necessary to verify that this information is <br /> correct and a 84e-Plot Plan showing the layout of monitoring equipment. For any equipment capable of generating such reports,I have <br /> also attached a copy of the report;(check aft that apply): System set-up Z Alarm history report <br /> Technician Name(print): PETER WESTBROOK Signature: <br /> Certification No.: B46676 License. No <br /> Testing Company Name: L.C.SERVICES Phone No.: 30 <br /> Testing Company Address: 3887 N VALENTINE FRESNO CA 93722 Date of Testing/Servicing: 8/30/2017 <br /> UN-036-1/6 www.unidocs.org Rev.01/17/08 <br />
The URL can be used to link to this page
Your browser does not support the video tag.