My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2013-2018
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
J
>
JACKSON
>
2501
>
2300 - Underground Storage Tank Program
>
PR0231488
>
COMPLIANCE INFO_2013-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/12/2021 12:06:22 PM
Creation date
6/23/2020 6:49:38 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2013-2018
RECORD_ID
PR0231488
PE
2361
FACILITY_ID
FA0003910
FACILITY_NAME
H&M - BW #98
STREET_NUMBER
2501
STREET_NAME
JACKSON
STREET_TYPE
AVE
City
ESCALON
Zip
95320
CURRENT_STATUS
01
SITE_LOCATION
2501 JACKSON AVE
P_LOCATION
06
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231488_2501 JACKSON_2013-2018.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
516
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
0 • <br />San Joaquin County <br />Environmental Health Department <br />1868 East Hazelton Avenue, Stockton, California 95205-6232 <br />Telephone: (209) 468-3420 Fax: (209) 468-3433 Web: www.sjgov.org/ehd <br />EMUnderground Storage Tank Program: ns . tion Report <br />,. <br />Facility Name: <br />Facility Address: <br />Date: <br />H&M - BW #98 <br />2501 JACKSON AVE, ESCALON <br />August 30, 2017 <br />SUMMARY OF VIOLATIONS <br />(CLASS I, CLASS 11, or�.MINQR - Notice to Comply) <br />Item # <br />Remarks <br />104 <br />CCR 2711 UST operating permit application for facility and tank information not submitted or current. <br />UST Tank Information forms for the all three tanks are not current in CERS. <br />Diesel: <br />-Incorrectly lists the tank primary as fiberglass. The tanks are made of steel. <br />-Incorrectly lists the vent piping primary as steel. The vent pipe is fiberglass. <br />87: <br />-Incorrectly lists the tank primary as fiberglass. The tanks are made of steel. <br />-Incorrectly lists the riser primary as fiberglass. <br />91: <br />-Incorrectly lists the tank primary as fiberglass. The tanks are made of steel. <br />-Incorrectly lists the tank secondary as unknown. <br />-Incorrectly lists the riser primary as fiberglass. <br />-Incorrectly states the site has a vent sump. <br />Any change of information must be updated in CERS within 30 days of the changes. Immediately log into CERS, <br />update the required information, and submit for review by the EH D. <br />This is a repeat violation, Class II. <br />107 <br />CCR 2632(d)(1)(C) Plot plan/site map not submitted or failed to completely show where monitoring is performed. <br />An accurate UST Monitoring Site Plan was not submitted. The site map does not include the locations of leak <br />detectors. A site plan must be submitted identifying the locations where monitoring will be performed. Immediately <br />log into the California Environmental Reporting System (CERS) at http://cers.calepa.ca.gov/ and upload a copy of <br />the UST Monitoring Site Plan. <br />This is a repeat violation, Class II. <br />109 <br />CCR 2637 Failed to test secondary containment. <br />Secondary containment testing was last performed on 6/11/14 and was due by June 2017. Testing has not been <br />completed and is two months past due. Secondary containment testing is required once every 36 months. This <br />testing has been scheduled for this afternoon and was observed to be started at the time of inspection. Ensure that <br />this test is completed and submit test results to the EHD within 30 days of testing. <br />This is a Class II violation. <br />Page 4 of 8 <br />
The URL can be used to link to this page
Your browser does not support the video tag.