My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2013-2018
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
J
>
JACKSON
>
2501
>
2300 - Underground Storage Tank Program
>
PR0231488
>
COMPLIANCE INFO_2013-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/12/2021 12:06:22 PM
Creation date
6/23/2020 6:49:38 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2013-2018
RECORD_ID
PR0231488
PE
2361
FACILITY_ID
FA0003910
FACILITY_NAME
H&M - BW #98
STREET_NUMBER
2501
STREET_NAME
JACKSON
STREET_TYPE
AVE
City
ESCALON
Zip
95320
CURRENT_STATUS
01
SITE_LOCATION
2501 JACKSON AVE
P_LOCATION
06
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231488_2501 JACKSON_2013-2018.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
516
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
W San <br />Joaquin <br />HealthEnvironmental Department <br />Hazelton1868 East • aCalifornia95205-6232 <br />Telephone. Y' I i•) 4W3433 Web.www.sigov.org/ehd <br />Underground i •Programi i Report <br />Facility Name: <br />HSC 25284 <br />No permit to operate <br />Facility Phone: <br />❑ R <br />Date: <br />102 <br />HSC 25284(x)(3) <br />No written agreement between tank owner and tank operator to monitor the tank system <br />❑ V <br />❑ R <br />❑ COS <br />Facility Address: <br />HSC 25292.2 <br />Current financial responsibility documents not submitted <br />❑ V <br />CERS ID: <br />_.. ..J� �F+ I us k...� " w s .. U i?._`,, tau <br />3 ... ✓:..:.l <br />CCR 2711 <br />UST operating permit application for facility and tank information not submitted or current <br />. ... -t <br />Inspection Contact: <br />❑ COS <br />Title: <br />CCR 2632(d)(1) <br />Phone: <br />❑ V <br />❑ R <br />t <br />106 <br />CCR 2632(d)(2) <br />Inspection Type: <br />❑ V <br />Program: <br />❑ COS <br />107 <br />CCR 2632(d)(1)(C) <br />Plot plan/site map not submitted or failed to completely show where monitoring is performed <br />■ V <br />Consent For: <br />Consent Given By: <br />108 <br />CCR 2637(0,2638(e) <br />Ml Ins ectlon Photos rx Sample <br />ib nes 'V'Valheeb,a ,1 <br />❑ R <br />Service Technician Onsite: <br />Exp. Date: <br />Designated Operator: <br />Exp. Date: <br />❑ V <br />I,,...2 -/I2 tsar' <br />Kat,,-,- n, i „a.._ <br />'�:.t `.f �,,�"�( 7 <br />Iservice Tecnnfclan ManuTacturers t raining: I <br />r_rtt = rtPus,,,,,i� rnriP of RPmuatinne HSC = HPalth and Safety Cnde CFR =Code of Federal Reoulations <br />V = Violation R = Repeat violation COS = Corrected on site during inspectio <br />I File Review I <br />101 <br />HSC 25284 <br />No permit to operate <br />❑ V <br />❑ R <br />❑ COS <br />102 <br />HSC 25284(x)(3) <br />No written agreement between tank owner and tank operator to monitor the tank system <br />❑ V <br />❑ R <br />❑ COS <br />103 <br />HSC 25292.2 <br />Current financial responsibility documents not submitted <br />❑ V <br />❑ R <br />❑ COS <br />104 <br />CCR 2711 <br />UST operating permit application for facility and tank information not submitted or current <br />■ V <br />❑ R <br />❑ COS <br />105 <br />CCR 2632(d)(1) <br />Failed to have an approved UST monitoring plan <br />❑ V <br />❑ R <br />❑ COS <br />106 <br />CCR 2632(d)(2) <br />Failed to have an approved UST response plan <br />❑ V <br />❑ R <br />❑ COS <br />107 <br />CCR 2632(d)(1)(C) <br />Plot plan/site map not submitted or failed to completely show where monitoring is performed <br />■ V <br />s R <br />❑ COS <br />108 <br />CCR 2637(0,2638(e) <br />Failed to notify the EHD 48 hours prior to conducting testing <br />❑ V <br />❑ R <br />❑ COS <br />109 <br />CCR 2637 <br />Failed to test secondary containment <br />❑ V <br />❑ R <br />❑ COS <br />110 <br />CCR 2637(e) <br />Failed to submit secondary containment test report within 30 days <br />❑ V <br />❑ R <br />❑ COS <br />111 <br />CCR 2638(a) <br />Failed to test monitoring and leak detection equipment annually <br />❑ V <br />❑ R <br />❑ COS <br />112 <br />HSC 25284.2 <br />Failed to test spill containers annually <br />❑ V <br />❑ R <br />❑ COS <br />113 <br />CCR 2638(d) <br />Failed to submit monitoring system certification test report within 30 days <br />❑ V <br />❑ R <br />❑ COS <br />114 <br />CCR 2636(f) <br />Failed to perform 0.1 gph annual line test for pressurized piping without fail safe or shut down <br />❑ V <br />❑ R <br />❑ COS <br />115 <br />CCR 2715(a) <br />Failed to inform the EHD of designated operator identification or change within 30 days <br />❑ V <br />❑ R <br />❑ COS <br />116 <br />CCR 2715 <br />Designated operator, service tech or installer did not possess current ICC certification <br />❑ V <br />❑ R <br />❑ COS <br />117 <br />CCR 2663 <br />Failed to inspect a lined or repaired steel tank within 10 years of lining and every 5 years after <br />❑ V <br />❑ R <br />❑ COS <br />118 <br />CCR 2663 <br />Failed to submit tank lining certification within 30 days or to conduct proper tests <br />❑ V <br />❑ R <br />❑ COS <br />119 <br />HSC 25299 <br />Documents were falsified or misrepresented <br />❑ V <br />❑ R <br />❑ COS <br />120 <br />CCR 2635(d) <br />Failed to submit UST Certification of Installation/Modification <br />❑ V <br />❑ R <br />❑ COS <br />121 <br />CCR 2712(f) <br />Failed to submit a written response within 30 days of receiving an inspection report <br />■ V <br />❑ R <br />❑ COS <br />122 <br />1 CCR 2631 Q) <br />Failure to submit UST system component statement of compatibility for substance stored <br />❑ V <br />❑ R <br />❑ COS <br />Un Wte Kecoras <br />201 CCR 2712(b) Failed to maintain alarm logs and/or records of follow up actions ■ V ■ R ❑ COS <br />202 CCR 2712(b) Failed to maintain cathodic protection test records on site for at least 6112 years ❑ V ❑ R ❑ COS <br />203 CCR 2712(b) I Failed to maintain records of monitoring, repair, lining, and upgrades on site ❑ V ❑ R ❑ COS <br />
The URL can be used to link to this page
Your browser does not support the video tag.