Laserfiche WebLink
IAL Aft 9171 9690 0935 0084 8437 43 <br />Facility Name: <br />H&M - BW #98 <br />San Joaquin County <br />Environmental Health Department <br />1868 East Hazelton Avenue, Stockton, California 95205-6232 <br />Telephone: (209) 468-3420 Fax: (209) 468-3433 Web: www.sjgov.org/ehd <br />Facility Phone: <br />209 838-3971 <br />, <br />'iS. <br />Date: <br />Jul 29 2015 <br />Facility Address: <br />2501 JACKSON AVE ESCALON CA 95320 <br />CERS ID: <br />10181511 <br />Inspection Contact: <br />Nofal Mohsin <br />Title: <br />Cashier <br />Phone: <br />209 838-3971 <br />Inspection Type: <br />ROUTINE INSPECTION - Operating Permit <br />Program: <br />12361 - UST FACILITY <br />Consent For: <br />0 Inspection 0 Photos 0 Sample <br />Consent Given By: <br />Nofal Mohsin Cashier <br />Service Technician Onsitec <br />Gary Harris <br />Exp. Date: <br />09/24/2015 <br />Designated Operator: <br />Karen Arnaiz <br />Exp. Date: <br />05/05/2017 <br />Service Technician Manufacturer's Training <br />VR 09/13/16; VMI 10/07/15 <br />CCR = California Code of Regulations HSC = Health and Safety Code CFR = Code of Federal Regulations <br />V = Violation R = Repeat violation COS = Corrected on site during inspection <br />101 HSC 25284 <br />No permit to operate <br />❑ V <br />❑ R <br />❑ COS <br />102 HSC 25284(a)(3) <br />No written agreement between tank owner and tank operator to monitor the tank system <br />❑ V <br />❑ R <br />❑ COS <br />103 HSC 25292.2 <br />Current financial responsibility documents not submitted <br />■ V <br />■ R <br />❑ COS <br />104 CCR 2711 <br />UST Operating Permit Application for Facility and Tank information not submitted or current <br />❑ V <br />❑ R <br />❑ COS <br />105 HSC 25286(c) <br />Current BOE number not submitted <br />❑ V <br />❑ R <br />❑ COS <br />106 CCR 2632 <br />Monitoring and response plans not current or approved by the EHD <br />❑ V <br />❑ R <br />❑ COS <br />107 CCR 2632(d)(1)(C) <br />Plot plan/site map not submitted or failed to completely show where monitoring is performed <br />■ V <br />❑ R <br />❑ COS <br />108 CCR 2637(f), 2638(e) <br />Failed to notify the EHD 48 hours prior to conducting testing <br />❑ V <br />❑ R <br />❑ COS <br />109 CCR 2637 <br />Failed to test secondary containment <br />❑ V <br />❑ R <br />❑ COS <br />110 CCR 2637(e) <br />Failed to submit secondary containment test report within 30 days <br />❑ V <br />❑ R <br />❑ COS <br />111 CCR 2638(a) <br />Failed to test monitoring and leak detection equipment annually <br />❑ V <br />❑ R <br />❑ COS <br />112 HSC 25284.2 <br />Failed to test spill containers annually <br />❑ V <br />❑ R <br />❑ COS <br />113 CCR 2638(d) <br />Failed to submit monitoring system certification test report within 30 days <br />❑ V <br />❑ R <br />❑ COS <br />114 CCR 2636(f) <br />Failed to perform 0.1 gph annual line test for pressurized piping without fail safe or shut down <br />❑ V <br />❑ R <br />❑ COS <br />115 CCR 2715(a) <br />Failed to inform the EHD of a change of designated operator within 30 days <br />❑ V <br />❑ R <br />❑ COS <br />116 CCR 2715 <br />Designated operator, service tech or installer did not possess current ICC certification <br />❑ V <br />❑ R <br />❑ COS <br />117 HSC 25292.5 <br />Failed to conduct ELD testing on a system located within 1 000'of a public well <br />❑ V <br />❑ R <br />❑ COS <br />118 HSC 25292.5 <br />Failed to repair and retest system due to failed ELD test <br />❑ V <br />❑ R <br />❑ COS <br />119 CCR 2644.1(a)(5) <br />Failed to submit ELD test results within 60 days <br />❑ V <br />❑ R <br />❑ COS <br />120 CCR 2663 <br />Failed to inspect a lined or repaired steel tank within 10 years of lining and every 5 years after <br />❑ V <br />❑ R <br />❑ COS <br />121 CCR 2663 <br />Failed to submit tank lining certification within 30 days or to conduct proper tests <br />❑ V <br />❑ R <br />❑ COS <br />122 HSC 25299 <br />Documents were falsified or misrepresented <br />❑ V <br />❑ R <br />❑ COS <br />123 CCR 2661 <br />Permit to repair UST system not obtained <br />❑ V <br />❑ R <br />❑ COS <br />124 CCR 2635(d) <br />Failed to submit UST Certification of Installation/Modification <br />❑ V <br />❑ R <br />❑ COS <br />125 CCR 2712(f) <br />Failed to submit a written response within 30 days of receiving an inspection report <br />❑ V <br />❑ R <br />❑ COS <br />Received by <br />(initial): <br />CAllFATINAH <br />Inspector: <br />ZAREEF, REHS <br />Phone: <br />(209) 953-7311 <br />Date: <br />07/29/2015 <br />Page 1 of 5 <br />