My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2013-2018
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
J
>
JACKSON
>
2501
>
2300 - Underground Storage Tank Program
>
PR0231488
>
COMPLIANCE INFO_2013-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/12/2021 12:06:22 PM
Creation date
6/23/2020 6:49:38 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2013-2018
RECORD_ID
PR0231488
PE
2361
FACILITY_ID
FA0003910
FACILITY_NAME
H&M - BW #98
STREET_NUMBER
2501
STREET_NAME
JACKSON
STREET_TYPE
AVE
City
ESCALON
Zip
95320
CURRENT_STATUS
01
SITE_LOCATION
2501 JACKSON AVE
P_LOCATION
06
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231488_2501 JACKSON_2013-2018.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
516
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SWRCB,January 2006 <br /> Spill Bucket Testing Report Form <br /> This form is intended for use by contractors performing annual testing MUST spill containment structures. The completed.1brin and <br /> printoutsfromtests(ij'applicable), should be provided to the facility ownerloperator.for submittal to the local regulatory agency. <br /> I. FACILITY INFORMATION <br /> Facility Name: H& M KWIK SERVE BW98 Date of Testing: 8/30/2017 <br /> Facility Address: 2501 E.JACKSON <br /> Facility Contact: MODESTO Phone: 209-838-31971 <br /> Date Local Agency Was Notified of Testing: <br /> LName of Local Agency Inspector(if present during tesflngl: <br /> 2. TESTING CONTRACTOR INFORMATION <br /> Company Name L.C.SERVICES <br /> Technician Conducting Test: PETER WESTBROOK <br /> Credentials': El CSLB Contractor X ICC Service Tech. 0 SWRCB-Tank Tester Fj Other(Specify) <br /> License N u m b e r(s):8 71'1 623 <br /> 3. SPILL BUCKET TESTING INFORMATION <br /> Test Method Used: X--Hydrostatic 110 Vacuum 1-1 Other <br /> Test Equipment Used: WATER Equipment Resolution:TAP <br /> Identify Spill Bucket (,qy Tank 1 87 FILL 2 91 FILL 3 DIESEL FILL 4 <br /> Number, Stared Product, etc.2_ <br /> Bucket inst--flanon, Direct Bury <br /> Typc: X Direct Bury X Direct Bury X Direct Bury I - <br /> Contained in Sump Contained in Sump Contained in Sump i..]Contained in Sum <br /> Bucket Diameter: 12" 12" 12" <br /> Bucket Depth: 14" 14" 14" <br /> Wait time between applying 30-MIN 30-MIN 30-MIN <br /> vacuum/water and start of test: <br /> Test Start Time(Ti): 9:OOAM 9:OOAM 9:OOAM <br /> Initial Reading(Rj): 14" 14" 15" <br /> Test End Time(TF): .10:00AM 10:OOAM I O:OOAM <br /> Final Reading(RF): 14" 4" 2" <br /> Test Duration(TF—T°): 1-HR I-HR I-HR <br /> Change in Reading(RF-R,): NONE NONE NONE <br /> Pass/Fai!Threshold or PASS FAILED FAILED <br /> Criteria: I <br /> [lest Result X Pass Fail X Pass Fail X Pass Fail 0 Pass []Fail <br /> Comments—(include information on repairs made Et for to testing, and recommended follolv-up.forfailed tests) <br /> DSL A 4D 91 FAILED WILL NEED TO REIURN FOR REPAIRS <br /> CERTIFICATION OF TECHNICIAN RESPONSIBLE FOR CONDUCTING THIS TESTING <br /> I hereby cerqy Iltat all the information coulahzed ft;this report is trite,accurate,and hi full compliance with legal requirements. <br /> Technician's Signature: --c Date: 7 <br /> p� V 4A47y <br /> State laws and regulations do not currently require testing to be performed by a qualified contractor. However, local requirements <br /> may be more stringent. <br />
The URL can be used to link to this page
Your browser does not support the video tag.