Laserfiche WebLink
ISD SITE ALARMS <br /> LEAK TEST METHOD <br /> - ISD GROSS PRES FAIL <br /> - - - - - - - - - <br /> TEST ON DATE : ALL TANK- ISD DEGRD PRES FAIL <br /> ISD VAPOR LEAK FAIL <br /> T 3:DIESEL JUL 1, 2009 ISD VP PRES FAIL <br /> PRODUCT CODE 3 START TIME : DISABLED <br /> THERMAL COEFF : .000450 TEST RATE :0.20 GAL/HR ISD VP STATUS FAIL <br /> TANK DIAMETER 95.75 DURATION 2 HOURS ISD SETUP FAIL <br /> TANK PROFILE I PT ISD SENSOR OUT FAIL <br /> FULL VOL 6016 TST EARLY STOP:DISABLED ISD HOSE ALARMS <br /> LEAK TEST REPORT FORMAT ALL:GROSS COLLECT FAIL <br /> FLOAT SIZE: 4.0 10. NORMAL ALL:DEGRD COLLECT FAIL <br /> WATER MINIMUM o.oqo ALL:FLOW COLLECT FAIL <br /> WATER WARNING 2.0 R 2:PREM <br /> HIGH WATER LIMIT: 3.0 TYPE: ' <br /> WATER ALARM FILTER: LOW STANDARD <br /> NORMALLY CLOSED <br /> MAX OR LABEL TANK #: 2 <br /> VOLUME 60116 <br /> HIGH PRODUCT LIQUID SENSOR ALMS <br /> % MAX 90.0 LIQUID SENSOR SETUP L 3:FUEL ALARM <br /> (GALLONS)' 5414 - - - - - - - - - - - - L 5:FUEL ALARM <br /> L 3:SENSOR OUT ALARM <br /> OVERFILL LIMIT L I :UNL STP L 5:SENSOR OUT ALARM <br /> % MAX 95.0 TRI-STATE (SINGLE FLOAT) L 3:SHORT ALARM <br /> (GALLONS) 5715 CATEGORY : STP SUMP L 5:SHORT ALARM <br /> ISD SITE ALARMS <br /> DELIVERY LIMIT ISD GROSS PRES FAIL <br /> % MAX 10.0 L 2:UNL ANN ISD DEGRD PRES FAIL <br /> (GALLONS) 602 TRI-STATE (SINGLE FLOAT) ISD VAPOR LEAK FAIL <br /> CATEGORY : ANNULAR SPACE ISD VP PRES FAIL <br /> LOW PRODUCT ISD VP STATUS FAIL <br /> VOLUME 600 ISD SETUP FAIL <br /> LEAK ALARM LIMIT: 20 L 3:PREM STP ISD SENSOR OUT FAIL <br /> SUDDEN LOSS LIMIT: 25 TRI-STATE (SINGLE FLOAT) <br /> TANK TILT 0.00 CATEGORY : STP SUMP ISD HOSE ALARMS <br /> ALL:GROSS COLLECT FAIL <br /> PROBE OFFSET 0.00 ALL:DEGRD COLLECT FAIL <br /> L 4:DIESEL STP ALL:FLOW COLLECT FAIL <br /> SIPHON MANIFOLDED TANKS TRI-STATE (SINGLE FLOAT) <br /> R 3:DIESEL <br /> T#: NONE CATEGORY : STP SUMP TYPE: <br /> LINE MANIFOLDED TANKS STANDARD <br /> TO: NONE L 5:PREM-DSL ANN NORMALLY CLOSED <br /> TRI-STATE (SINGLE FLOAT) TANK #: 3 <br /> LEAK MIN PERIODIC: 0% CATEGORY ANNULAR SPACE <br /> 0 <br /> LEAK MIN ANNUAL 05. LIQUID SENSOR ALMS <br /> 0 L 4:FUEL ALARM <br /> L 5:FUEL ALARM <br /> L 4:SENSOR OUT ALARM <br /> PERIODIC TEST TYPE L 5:SENSOR OUT ALARM <br /> L 4:SHORT ALARM <br /> STANDARD L 5:SHORT ALARM <br /> ANNUAL TEST FAIL <br /> ALARM DISABLED <br /> PERIODIC TEST FAIL <br /> ALARM DISABLED OUTPUT RELAY SETUP <br /> - - - - - - - - - - -- - <br /> GROSS TEST FAIL <br /> ALARM DISABLED R 1 :UNL <br /> TYPE. <br /> AN14 TEST AVERAGING: OFF STANDARD <br /> PER TEST AVERAGING: OFF NORMALLY CLOSED SMARTSENSOR SETUP <br /> - - - - - - - - - - <br /> TANK TEST NOTIFY: OFF TANK #: I - - <br /> 5 <br /> TNK TST SIPHON BREAK OFF C 1 :1-2 ISD <br /> LIQUID SENSOR ALMS CATEGORY AIR FLOW METER <br /> DELIVERY DELAY 15 MIfq L 1 :FUEL ALARM <br /> 2: <br /> PUMP THRESHOLD 10.00% L 2:FUEL ALARM 5 3-4 ISD <br /> L I :SENSOR OUT ALARM CATEGORY AIR FLOW METER <br /> L 2:SENSOR OUT ALARM s 8:3-4 VAPORPRESS <br /> L l :SHORT ALARM CATEGORY VAPOR PRESSURE <br /> L 2'.SHORT ALARM <br />