Laserfiche WebLink
r <br /> • 0 Time In: <br /> Time Out: <br /> Qi,au�n. San Joaquin County <br /> x �9.o <br /> Environmental Health Department <br /> W. 'A <br /> 1868 East Hazelton Avenue, Stockton, CA 95205-6232 <br /> p Telephone:(209)468-3420 Fax:(209)464-0138 Web:www.s*gov.org/ehd <br /> Underground Storage Tank Program Service Request Inspection Report <br /> Name of Facility: H&M-BW#98 Date: 08/03/2018 <br /> Address: 2501 E JACKSON AVE , ESCALON 95320 <br /> Requestor: MARTY WEITHMAN, SERVICE STATION SYSTEMS INC Telephone: (408)213-6038 <br /> Program Element: 2308-UST RETROFIT Request#: SR0079458 <br /> Inspection Type: 298-UST RETROFIT REPAIR INSPECTION <br /> Onsite Service Technician: Jeff Carmo ICC Service Tech/Installer Exp. Date: 04/19/2020 <br /> Manufacturer training: FFS EVR Phase I systems, 01/31/20 <br /> =Y 1 lERA INSPECTION IV(QTES AICD COMMENTS 6r <br /> NOTES <br /> On site to verify corrosion protection for the 87 product direct bury spill container prior to backfilling.While on site found that <br /> the spill container that was approved by EHD, Phil-tite 85101-V was exchange to a 5 Gallon, single Walled, Field Replaceable <br /> Spill Container. Called the program coordinator who stated that it was okay for the company to use 5 Gallon,single Walled, <br /> Field Replaceable Spill Container.While on site received an email from Ryan Brownlee with the cut sheet for the 5 Gallon, <br /> single Walled container.The program coordinator asked me to review the cut sheet on site to check fuel compatibility. The cut <br /> sheet states that the spill container is UL listed and CARB approved, it also states that it has a 5 gallon capacity, however that <br /> was not verified at this time.Verify that the riser was cover with 2 inch, 20 MIL pipe wrap tape to protect it from corrosion,the <br /> rest of the spill container was isolated from backfill to meet corrosion protection verification.This service request is not <br /> completed at this time.A verification of a minimum 5 gallon capacity, a one hour hydrostatic test(or equivalent)along with <br /> proper drainage, and secondary containment testing on the 87 product tank must be verify in order for the facility to receive 87 <br /> product fuel. <br /> The person in charge is responsible for ensuring that the above mentioned facility is in compliance with all applicable sections of the California Health and <br /> Safety Code.If a reinspection is required,fees will be assessed at the current hourly rate. <br /> Received by: Name and Title: Jeff Carmo,Service Technician <br /> EH Specialist: ZUNA BARKER Phone: (209)953-7311 <br /> FA0003910 SR0079458 SC298 08/03/2018 <br /> EHD 23-01 Rev.06/30/15 Page 1 of 1 Underground Storage Tank Program Service Request Inspection Report <br />