Laserfiche WebLink
SAN JOAQUIN COUNTY <br /> ENVIRONMENTAL HEALTH DEPARTMENT <br /> 600 East Main Street, Stockton, California 95202-3029 <br /> Telephone:(209)468-3420 Fax:(209)468-3433 Web:www.sogov.or-/ehd/unitiii.html <br /> UNDERGROUND STORAGE TANK(UST) PROGRAM INSPECTION REPORT <br /> Fae ty name. Inspection data. <br /> United Parcel Service Stockton/Lodi Jun 15, 2010 <br /> Facility address: UST S/ 3 <br /> 1532 N. Broadway Product /DSL <br /> Facility contact: Title: Phone. <br /> Kasi Montgomery Plant Eng Supervisor 916-857-0323 <br /> Monitoring panel: Piping system: Overfill prevention: Violations: <br /> GMechanical M1-RDetect M3-Both <br /> Veeder-Root TLS-350 Pressurized Q Suction Q ravity <br /> ®Audible/visual M2-RPrev <br /> Inspection type: Designated operator. ICC exp.dab: <br /> ©Routine 0 Monitoring Certification Installation ❑Other Dan Zeman/Mike Zeman 3/3/11; 11/15/10 <br /> On ske Service Technician's name: ICC exp.date: Manufacturer's training: <br /> Dan Zeman (5243781-UC) 6/20/2011 Veeder-Root Lvl 4#A32807 3/8/2012 <br /> # Code Section VIOLATIONS V R <br /> HSC=CA Health&SafetyCode;CCR=CA Code of Regulations;V=Violation; RV=Re eat Violation v <br /> 1 HSC 25284 No permit to operate <br /> Secondary containment: (a)test not performed; (e)test report not submitted within 30 days; (f)test <br /> 2 CCR 2637 notification not provided to the Environmental Health Department(EHD)at least 48 hours prior to <br /> conducting the test <br /> 3 CCR 2711(b)&(c) Current Unified Program Consolidated Forms not on file with the EHD(Facility and tank form) <br /> 4 HSC 25292.2 Current financial responsibility documents not on file with the EHD <br /> 5 CCR 2632(b) Monitoring Program(Monitoring&Response Plans)is not current or approved by the EHD X <br /> 6 CCR 2712(i) Monitoring and/or response plan is not onsite <br /> Maintenance&monitoring records not maintained 3 years,cathodic protection records for 6'/2 (M�) <br /> years,written performance claims pertaining to release detection systems for 5 years,or records of <br /> repairs, linings, and upgrades for the life of the tank. Monitoring records include: (1)date and time of <br /> 7 CCR 2712(b) all monitoring or sampling; (2)monitoring equipment calibration and maintenance records; (3)results <br /> of any visual observations; (4)results of sample analysis performed a lab or in the field; (5)logs of all <br /> readings of gauges or other monitoring equipment,ground water elevations,or other test results;(6) <br /> results of inventory readings and reconciliations <br /> 8 CCR 2643(d) Daily monitoring of suction piping(pre-January1, 1984 not performed (M1) <br /> 9 HSC 25292.1 UST system is not operated to prevent unauthorized release, including spills and overfills <br /> 10 CCR 2632(c)(2) Monitoring system is not present in the interstitial space of a double walled UST/piping (M9) <br /> 11 CCR 2630(d) UST monitoring equipment is not installed or maintained to detect a leak at the earliest opportunity(m) <br /> 12 HSC 25291(b) UST monitoring system incapable of detecting leak from primary containment into secondary (M1) <br /> containment <br /> 13 CCR 2636(f)(1) Failed to maintain a continuous monitoring system for underground piping&UDCs that activates (M1) <br /> an audible and visual alarm or stops flow of product at the dispenser when it detects a leak <br /> 14 CCR 2631(a) Primary containment is not product tight <br /> 15 HSC 25291(a)(2) Secondary containment for UST system is not tight <br /> 16 CCR 2636(c)(1) All releases in secondary pipingdo not flow to a collection sum <br /> 17 CCR 2636(f)(2) Line leak detectors not installed or failed to detect a 3-gallon per hour leak at 10 psi (Mi) <br /> 18 CCR 2635(b)(1) Spill container not installed,failed to contain a minimum capacity of five gallons, or failed to (M2) <br /> provide a means to keep the spill container empty <br /> 19 CCR 2635(b)(2) Overfill revention system was overridden or failed to meet overfill requirements in this section (M2) <br /> 20 CCR 2636(a) Failed to have secondary containment for piping(includes conventional suction piping) (M2) <br /> 21 HSC 25291 a Water in 2°containment not removed,analyzed&properly disposed of <br /> Unauthorized release that: (c)did not escape secondary containment and cleaned up within eight (Mi) <br /> 22 CCR 2650 hours was not recorded; (e)escaped secondary containment, not cleaned up after eight hours,or a <br /> sudden loss of product was not reported to the EHD within 24 hours <br /> 23a CCR 2715(a) Failed to inform the EHD of a change of designated operator within 30 days <br /> 23b I CCR 2715(b) Desi nated operator did not possess a current ICC UST System Operator certification <br /> EHD inspector Received by: Title: <br /> WAk (8, 7010 <br /> EHD 23-02-00 RE 8/10 Page 1 UST OFFICIAL INSPECTION REPORT <br />