My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_1985-2007
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
D
>
DE VRIES
>
13850
>
2300 - Underground Storage Tank Program
>
PR0231547
>
COMPLIANCE INFO_1985-2007
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/8/2023 2:12:37 PM
Creation date
6/23/2020 6:49:46 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1985-2007
RECORD_ID
PR0231547
PE
2361
FACILITY_ID
FA0003848
FACILITY_NAME
Verizon Business: KINGCA
STREET_NUMBER
13850
Direction
N
STREET_NAME
DE VRIES
STREET_TYPE
RD
City
LODI
Zip
95240
APN
05524018
CURRENT_STATUS
01
SITE_LOCATION
13850 N DE VRIES RD
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231547_13850 N DE VRIES_1985-2007.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
401
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
11 <br />Monitoring System Certification <br />For Use By All Jurisdictions Within the State of California <br />Authority Cited: Chapter 6.7, Health and Safety Code; Chapter 16, Division 3, Title 23, Califomia Code of Regulations <br />This form must be used to document testing and servicing of monitoring equipment. A separate certification or report must be prepared for each monitoring <br />system control panel by the technician who performs the work. A copy of this form must be provided to the tank system owner/operator. The owner/operator <br />must submit a copy of this form to the local agency regulating UST systems within 30 days of test date. <br />A. General Information <br />Facilty Name: Verizon KINGCA <br />Site Address: 13850 Devries <br />Facility Contact Person: Colby Hoepfner <br />Make/Model of Monitoring System: Pneumercator TMS2000 <br />B. Inventory of Equipment Tested/Certified <br />Check the a propriate boxes to indicate specific equipment inspectediserviced: <br />Bldg. No.: <br />City: Lodi <br />Zip: <br />Phone: (972) 729-5182 <br />Date if Testing/Service: 09/13/07 <br />P <br />Tank ID: Diesel <br />Tank ID: <br />❑✓ In Tank Guaging Probe. <br />Model: 450 <br />❑ In Tank Guaging Probe. <br />Model: <br />❑✓ Annular Space Sensor. <br />Model: LS610 <br />❑ Annular Space Sensor. <br />Model: <br />❑✓ Piping Sump / Trench Sensor(s). <br />Model: LS600 <br />❑ Piping Sump / Trench Sensor(s). <br />Model: <br />❑ Fill Sump Sensor(s). <br />Model: <br />❑ Fill Sump Sensor(s). <br />Model: <br />❑ Mechanical Line Leak Detector. <br />Model: <br />❑ Mechanical Line Leak Detector. <br />Model: <br />❑ Electronic Line Leak Detector. <br />Model: <br />❑ Electronic Line Leak Detector. <br />Model: <br />❑ Tank Overfill / High Level Sensor. <br />Model: <br />❑ Tank Overfill / High Level Sensor. <br />Model: <br />Other (specify equipment a and model in Section E on Page 2). <br />F1 other (sDecifv equipment a and model in Section E on Page 2 . <br />TankID: <br />ank ID: <br />❑ In Tank Guaging Probe. <br />Model: <br />❑ In Tank Guaging Probe. <br />Model: <br />❑ Annular Space Sensor. <br />Model: <br />❑ Annular Space Sensor. <br />Model: <br />❑ Piping Sump / Trench Sensor(s). <br />Model: <br />❑ Piping Sump / Trench Sensor(s). <br />Model: <br />❑ Fill Sump Sensor(s). <br />Model: <br />❑ Fill Sump Sensor(s). <br />Model: <br />❑ Mechanical Line Leak Detector. <br />Model: <br />❑ Mechanical Line Leak Detector. <br />Model: <br />❑ Electronic Line Leak Detector. <br />Model: <br />❑ Electronic Line Leak Detector. <br />Model: <br />❑ Tank Overfill / High Level Sensor. <br />Model: <br />❑ Tank Overfill / High Level Sensor. <br />Model: <br />Other (specify equipment a and model in Section E on Page 2). <br />Other (specify equipment a and model in Section E on Page 2). <br />Dispenser ID: <br />Dispenser ID: <br />❑ Dispenser Containment Sensor. <br />Model: <br />❑ Dispenser Containment Sensor. <br />Model: <br />❑ Shear Valve(s). <br />❑ Shear Valve(s). <br />Dispenser Containment Float(s) and Chain(s). <br />Dis enser Containment Float(s) and Chain(s). <br />Dispenser ID: <br />Dispenser ID: <br />❑ Dispenser Containment Sensor. <br />Model: <br />❑ Dispenser Containment Sensor. <br />Model: <br />❑ Shear Valve(s). <br />❑ Shear Valve(s). <br />Dis enser Containment Floats and Chain(s). <br />Dispenser Containment Float(s) and Chain(s). <br />Dispenser ID: <br />Dispenser ID: <br />❑ Dispenser Containment Sensor. <br />Model: <br />❑ Dispenser Containment Sensor. <br />Model: <br />❑ Shear Valve(s). <br />❑ Shear Valve(s). <br />Dispenser Containment Float(s) and Chain(s). <br />Dispenser Containment Float(s) and Chain(s). <br />"If the facility contains more tanks or dispensers, copy this form. Include information for every tank and dispenser at the facility. <br />C. Certification - I certify that the equipment identified in this document was inspected/serviced in accordance with the manufacturers' <br />guidelines. Attached to this Certification is information (e.g. manufacturers' checklists) necessary to verify that this information is correct and <br />a Plot Plan showing the layout of monitoring equipment. For any equipment capable of generating such reports, I have also attached a copy of <br />the report; (check all that apply): <br />2 System set-up ❑✓ Alarm History Report <br />Technician Name: Robert Henninger Signature: <br />Certification No.: 10588 Liscense No.: 396575 A / B/ C-10 / HAZ <br />Testing Company Name: Balch Petroleum Phone No.: 408-942-8686 <br />Site Address: 930 Ames Ave, Milpitas, CA Date of Testing/Service: 09/13/07 <br />Page 1 of 3 <br />
The URL can be used to link to this page
Your browser does not support the video tag.