COMPLIANCE INFO_1985-2007
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
D
>
DE VRIES
>
13850
>
2300 - Underground Storage Tank Program
>
PR0231547
>
COMPLIANCE INFO_1985-2007
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/8/2023 2:12:37 PM
Creation date
6/23/2020 6:49:46 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1985-2007
RECORD_ID
PR0231547
PE
2361
FACILITY_ID
FA0003848
FACILITY_NAME
Verizon Business: KINGCA
STREET_NUMBER
13850
Direction
N
STREET_NAME
DE VRIES
STREET_TYPE
RD
City
LODI
Zip
95240
APN
05524018
CURRENT_STATUS
01
SITE_LOCATION
13850 N DE VRIES RD
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231547_13850 N DE VRIES_1985-2007.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
401
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
UNIFIED PROGRAM CONSOLIDATED FORM <br /> TANKS <br /> UNDERGROUND STORAGE TANKS -TANK PAGE 1 <br /> (Two pages per tank) <br /> Page ` of <br /> TYPE OF ACTION ❑ I.NEW PERMIT ❑ 4.AMENDED PERMIT Rr5.CHANGE OF INFORMATION ❑ 6.TEMPORARY TANK CLOSURE 430. <br /> (Check one item only) ❑ 3.RENEWAL PERMIT GAtt �s e� �Z ❑ 7.PERMANENTLY CLOSED ON SITE <br /> (Specify reason) (Specify reason) ❑ 8.TANK REMOVED <br /> BUSINESS NAME(Same as FACILITY NAME or DBA-Doing Business As) 3. FACILITY ID: I. <br /> �. td+ oa ® <br /> LOCATION WITHIN SITE(Optional) ` 431. <br /> IyT lllC "TION <br /> •. <br /> (--A:scaled plot plan wrtb.the location of the UST sysiem laclud` 'Wldin '"and landmarks shall be submitti6d to the loyal"a"envy). <br /> TANK ID# 432. TANK MA ACTURER 433. COMPARTMENTALIZED TANK Yes 610No 434. <br /> If"Yes,"complete one page for each compartment. <br /> DATE INSTALLED 435. TANK CAPACITY IN GALLONS 436. NUMBER OF COMPARTMENTS 437 <br /> (YEAR/MO) <br /> ADDITIONAL DESCRIPTION(For local use only) 438. <br /> IIT0 UNTENT . <br /> TANK USE 439. PETROLEUM TYPE 440.E <br /> ❑ 1. MOTOR VEHICLE FUEL ❑la. REGULAR UNLEADED [32. LEADED [15. JET FUEL <br /> (If c ked,complete Petroleum Type) El lb. PREMIUM UNLEADED ;K. DIESEL ❑6. AVIATION GAS <br /> 72. NON-FUEL PETROLEUM ❑lc. MIDGRADE UNLEADED ❑4. GASOHOL ❑99.OTHER: <br /> ❑ 3. CHEMICAL PRODUCT COMMON NAME (from Hazardous Materials Inventory page) `al' CAS#(from Hazardous Materials Inventory page) 442. <br /> ❑ 4. HAZARDOUS WASTE <br /> (Includes Used Oil) `L <br /> ❑ 95.UNKNOWN <br /> III,TANK CONSTRUCTION <br /> TYPE OF TANK D 1. SINGLE WALL 0 3. SINGLE WALL WITH EXTERIOR ❑5. SINGLE WALL WITH INTERNAL BLADDER SYSTEM 443. <br /> (Check one item only) MEMBRANE LINER ❑95. UNKNOWN <br /> 2. DOUBLE WALL ❑4 SINGLE WALL IN A VAULT ❑99. OTHER <br /> TANK MATERIAL-primary tank 1. BARE STEEL JjM. FIBERGLASS/PLASTIC 5. CONCRETE 95.UNKNOWN 444. <br /> (Check one item only) ❑2. STAINLESS STEEL [34. STEEL CLAD W/FIBERGLASS ❑8. FRP COMPATIBLE [199.OTHER: <br /> REINFORCED PLASTIC FRP W/100%METHANOL <br /> TANK MATERIAL-secondary tank 1. BARE STEEL Ur. FIBERGLASS/PLASTIC 8. FRP COMPTIBLE W/100%METHANOL 95.UNKNOWN 445. <br /> (Check one item only) ❑2. STAINLESS STEEL❑4. STEEL CLAD W/FIBERGLASS ❑9. FRP NON-CORRODABLE JACKET ❑99.OTHER <br /> REINFORCED PLASTIC(FRP) ❑10. COATED STEEL <br /> ❑5. CONCRETE <br /> TANK INTERIOR LINING 0 1.RUBBER LINED 3.EPDXY LINING 0 5.GLASS LINING 95.UNKNOWN 446. DATE INSTALLED 447. <br /> OR COATING ❑2.ALKYD LINING ❑4.PHENOLIC LINING [16.UNLINED ❑99.OTHER <br /> Check one item only) <br /> OTHER CORROSION 0 1.MANUFACTURED CATHODIC 934.FIBERGLASS REINFORCED PLASTIC 95.UNKNOWN 448. DATE INSTALLED 449. <br /> PROTECTION PROTECTION ❑4.IMPRESSED CURRENT ❑99.OTHER <br /> If Applicable) ❑2.SACRIFICIAL ANODE <br /> SPILL AND OVERFILL YEAR INSTALLED 450. TYPE 451, OVERFILL PROTECTION EQUIPMENT: YEAR INSTALLED 452. <br /> (Check all that apply) 1.SPILL CONTAINMENT 2001 1.ALARM ❑3.FILL TUBE SHUT OFF VALVE_ <br /> 2.DROP TUBE 2.BALL FLOAT ❑4.EXEMPT <br /> 3.STRIKER PLATE <br /> I "TANEiK DETECTION <br /> (A Seri "oq of the Mo 4` ro.. shall be submitted Wjhe local a eti .)," <br /> IF SINGLE WALL TANK 453. IF DOUBLE WALL TANK OR TANK WITH BLADDER 454. <br /> (Check all that apply) (Check one item only) <br /> ❑1.VISUAL(EXPOSED PORTION ONLY) ❑5.MANUAL TANK GAUGING(MTG) ❑1.VISUAL(SINGLE WALL IN VAULT ONLY) <br /> [12.AUTOMATIC TANK GAUGING(ATG) ❑6.VADOSE ZONE MI<CONTINUOUS INTERSTITIAL MONITORING <br /> ❑3.CONTINUOUS ATG ❑7.GROUNDWATER ❑3.MANUAL MONITORING <br /> ❑4.STATISTICAL INVENTORY RECONCILIATION ❑8.TANK TESTING <br /> (SIR)+BIENNIAL TANK TESTING ❑99.OTHER <br /> V.TANK CLOS tTE ISA ©N f''PERMANENT'CLOSC122E IN PLACE <br /> ESTIMATED DATE LAST USED(YR/MO/DAY) 455. ESTIMATED QUANTITY OF SUBSTANCE REMAINING 456' TANK FILLED WITH INERT MATERIAL? 457' <br /> gallons ❑Yes ❑ No <br /> UPCF hwhvrc-b(1/99)-1/4 www.unidocs.org Rev.02/16/00 <br />
The URL can be used to link to this page
Your browser does not support the video tag.