Laserfiche WebLink
SAN JOAQUIN COUNTY ua -- � -7 <br />SAN <br />P R# <br />'VVIRONMENTAL HEALTH DEPARTI PAGE / <br />E. Weber Ave., Thir Flo - Stockton, C 1202 <br />(209) 620 <br />UNDERGROUND STORAGE TANK (IST) PROGRAM INSPECTION REPORT <br />Facility Name u ,r Facility Address <br />Facilty Contact Title Phone # <br />UST#� J Product - _ USTAZ_Product 12- UST#13 Product_UST# Product - <br />Overfill Trevention: <br />roductOverfillTrevention: ❑ AudibleNisual SW�I`echanical Monitoring Panel: r (t7alCp1,440 <br />Piping System: ❑ Gravity Q41r-essure ❑ Suction� Violations: C3-tatinor ❑ Major <br />Automatic Pump Shut Down Satisfies CCR 2636 (g): CP es ❑ No Dispenser Pan: &Ye's ❑ No <br />INSPECTION TYPE: <br />COMPANY NAME: <br />utine tMonitoring Certification ❑Complaint ❑install ❑Removal ❑Repair/Upgrade <br />TECHNICIAN NAME: <br />VIOLATIONS) <br />PHONE: Z61 Wh 5' - <br />The above facility is not in compliance with the following section(s) of Health & Safety Code (HSC) and/or <br />California Code of Regulations (CCR): <br />1 HSC 25284 <br />2 CCR 2637 <br />3 CCR 2711(b) & (c) <br />4 HSC 25292.2 <br />5 CCR 2630 (d) <br />6 CCR 2636 (c)(1) <br />7HSC 25291 (e) <br />8ZHSC 25291 (f) <br />9 CCR 2636 (f)(1) <br />10 CCR 2632 (c)(2) <br />11 HSC 25291(a)(2) <br />12 CCR 2636 (f)(1) <br />13,_ZCCR 2635 (b)(1) <br />14 CCR 2635 (b)(2) <br />15=CCR 2631 (a) <br />16 HSC 25292.1 <br />17 CCR 2650 <br />18 CCR 2632 (d) <br />19 CCR 2712 (i) <br />EHD INSPECTOR: <br />Permit to operate <br />20 <br />CCR 2712 (b) <br />Maintenance & monitoring <br />Secondary cont testing (6 <br />records <br />month/36 month) <br />21 <br />CCR 2636 (f)(4) <br />Annual line tightness test <br />Current State Forms A & B <br />- 22 <br />CCR 2630 (d) <br />Annual line leak detector test <br />Certification of financial �iL <br />23 <br />CCR 2630 (d) <br />Annual monitoring certification <br />responsibility and letter from <br />24 <br />CCR 2643 (d) <br />Daily monitoring of suction <br />chief financial officer <br />piping that is not continuously <br />Continuous monitoring system <br />monitored <br />for UST system <br />25 <br />CCR 2636 (a) <br />Conventional suction piping <br />All releases in secondary piping <br />shall have continuous <br />flow to a collection sump <br />monitoring & 20 containment <br />Water in secondary (2°) cont <br />26 <br />CCR 2643 (e) <br />Biennial tightness test of gravit:. <br />Automatic line leak detector(s) <br />piping that is not continuously <br />Continuous monitoring system <br />monitored <br />for underground piping <br />27 <br />CCR 2662 <br />Upgrade requirements for UST <br />Continuous monitoring system <br />system <br />for UST <br />28 <br />CCR 2661 <br />Permit to repair UST system <br />Secondary containment for <br />29 <br />HSC 25286 (a) <br />Permit to alter monitoring <br />UST is tight <br />system <br />Continuous monitoring system <br />30 <br />HSC 25298 (a) <br />Illegal abandonment of UST <br />for dispenser system <br />system <br />Spill container <br />31 <br />HSC 25298 (b) <br />Permit to temporarily close US' <br />Overfill prevention system <br />system <br />Primary containment is product- <br />32 <br />HSC 25298 (c) <br />Permit to close UST system <br />tight <br />33 <br />HSC 25291 (e) <br />Water in 20 cont analyzed and <br />UST system is operated to <br />properly disposed of <br />prevent unauthorized release <br />34 <br />CCR 2640 (e) <br />Single wall component within <br />Recording/reporting <br />1000' of Public Well, no ELD <br />unauthorized release <br />35 <br />CCR 2635(a)(2)(A) Cathodic protection testing <br />Monitoring & response plan <br />36 <br />H&SC 25299(a)(9) Disabling leak detect. devices <br />Monitoring & response plan is <br />37 <br />Violation(s) not listed above <br />on site <br />PHONE: �x)") L/hN <br />F RECEIVED BY: l/ U 'TITLE: <br />UNMIVUST11NSP (rev 7/2402) <br />