My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2005-2012
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
F
>
FREMONT
>
4100
>
2300 - Underground Storage Tank Program
>
PR0231574
>
COMPLIANCE INFO_2005-2012
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/1/2021 11:53:40 AM
Creation date
6/23/2020 6:50:08 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2005-2012
RECORD_ID
PR0231574
PE
2361
FACILITY_ID
FA0002123
FACILITY_NAME
GREWALS GAS & LIQUOR*
STREET_NUMBER
4100
Direction
E
STREET_NAME
FREMONT
STREET_TYPE
ST
City
STOCKTON
Zip
95215
APN
14333046
CURRENT_STATUS
01
SITE_LOCATION
4100 E FREMONT ST
P_LOCATION
99
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231574_4100 E FREMONT_2005-2012.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
236
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
N JOAQUIN COUNTY <br /> ENVIRONMENTAL HEALTH DEPARTMENT <br /> 600 East Main Street, Stockton, California 95202-3029 <br /> Telephone: (209)468-3420 Fax:(209)468-3433 Web: .siaov.orci/ehd/unitiii.html <br /> UNDERGROUND STORAGE TANK (UST) PROGRAM INSPECTION FST <br /> CONTINUED <br /> Facility address: Inspection Date: <br /> 2 <br /> Code Section VIOLATION(S) HSC=California Health&Safety Code;CCR=California Code of Regulations V R <br /> V=Violation;RV=Re eat Violation V <br /> Monitoring equipment certification:(a)not performed annually;(d)test report not submitted within 30 days;(e)test <br /> 24 CCR 2638 notification not provided to the EHD at least 48 hours prior to conducting an installation,repair,replacement, <br /> calibration,or certification;(f)performed,and failed to affix a tag/sticker on each monitoring equipment <br /> component that was certified,repaired,or replaced <br /> 25 CCR 2638 Annual line leak detector test:(a)not performed;(d)test report not submitted within 30 days (M1) <br /> 26 HSC 25284.2 Annual spill containment testing not performed <br /> 27 CCR 2636 4 Annual line tightness test not performed if positive shutdown or fail safe not present <br /> 28 CCR 2661 Repair for tank or piping not tested for tightness within 30 days of completion of the repair (M2) <br /> 29 CCR 2643(e) Biennial tightness test of gravity piping not performed(pre-January 1, 1984) <br /> 30 CCR 2643(d) Triennial line test for conventional suction piping not performed(pre-January 1, 1984) (M1) <br /> 31 HSC 25292.5 ELD testing not performed on a system located within 1000'of public well,or failures not repaired and retested <br /> 32 CCR 2661 Permit to repair UST system not obtained <br /> 33 HSC 25286(a) Permit to alter monitoring system not obtained <br /> 34 HSC 25298(b) Permit to temporarily close UST system not obtained <br /> 35 HSC 25298(c) Permit to close UST system not obtained <br /> 36 HSC 25299 a 9 Tampering with or disabling leak detection devices or alarms <br /> 37 HSC 25298 a Illegally abandoned UST system <br /> 38 HSC 25281.5(b)(2) Unburied fuel piping at marinas not visually inspected at least monthly or log not kept <br /> 39 CCR 2631.1 a UST system is not compatible with the substance stored <br /> Emergency gen <br /> 40 CCR 2636(f)(6) Emergency generator monitoring system not checked daily or log not kept ( 1) <br /> 41 HSC 25281.5(b)(: Unburied fuel piping not visually inspected at least monthly or log not kept (M1) <br /> VPH§ystems HSC'2 .2It 07/01103 and 7(installed on or after 07101 <br /> Compatibility and permeability requirements:(a)UST system is not compatible with the substance stored;(b) <br /> 42 CCR 2631.1 results of the compatibility and permeability testing requirements listed in subsections CCR 2631(b)and(d)for a <br /> UST system installed after July 1,2004,were not submitted <br /> 43 HSC 25290.1(0)(1) Primary containment not liquid or vapor tight <br /> HSC 25290.2(c)(1) <br /> 44 HSC 25290.1(c)(2) Secondary containment not liquid or vapor tight <br /> HSC 25290.2(c)(2) <br /> 45 HSC 25290.1(c)(3) Secondary containment not constructed to prevent water intrusion <br /> HSC 25290.2(c 3 <br /> 46 HSC 25290.1(d) Monitoring system not maintained to detect water intrusion into the secondary containment,or the entry of liquid <br /> HSC 25290.2(d) or vapor from the primary containment into the secondary containment <br /> 47 HSC 25290.1(e) Interstitial liquid measurement method,constant vacuum,or constant pressure in the interstitial space of the UST <br /> s stem not maintained <br /> 48 HSC 25290.10) UST system not tested by one of the following methods prior to use:(1)Enhanced leak detection;(2)inert gas <br /> HSC 25290.2(i) pressure test approved by SWRCB;(3)test method deemed equivalent to(1)or(2)by the SWRCB <br /> Other violations <br /> —99--i-Other: <br /> Acll?lclm"� Alto— A CI (c "r 1 o GC <br /> r <br /> ALL EHD STAFF TIME ASSOCIATED WITH FAILING TO COMPLY BY THE ABOVE NOTED DATES WILL BE BILLED AT THE CURRENT HOURLY RATE <br /> THIS FACILITY IS SUBJECT TO REINSPECTION AT ANY TIME AT EHD'S CURRENT HOURLY RATE. <br /> EHD INSPECTOR: PHONE: UIC <br /> vi1' 4� - Septic system: <br /> ❑Serves>_20 people/day <br /> 77 <br /> RECEIV Y: TITLE: ❑Receives other than sanitary waste <br /> Other disposal methods: <br /> ` ❑D wells/French Drains <br /> EHD -02-002 REV 12/09 Page 2 UST INSPECTION REPORT <br />
The URL can be used to link to this page
Your browser does not support the video tag.