Laserfiche WebLink
0 SAN JOAQUIN COUNTY • <br /> ENVIRONMENTAL HEALTH DEPARTMENT <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone:(209)468-3420 Fax: (209)468-3433 Web:www.sigov.org/ehd <br /> UNDERGROUND STORAGE TANK (UST) PROGRAM INSPECTION REPORT <br /> Faculty Grewal's Gas & Liquor Facility 4100 E. Fremont Stockton Inspection Apr 16 2014 <br /> Name: q Address: , Date: p , <br /> Facility Amrit Grewal Title: owner 6W-b797 <br /> Contact: <br /> Inspection XRoutine XMonitoring System Certification ❑Installation I Complaint-ID#: ❑Other: <br /> Type: <br /> (Authority HSC 25289) Amrit Grewal owner <br /> Consent for: Xlnspection �;Sampling XPhotos Granted by: Title: <br /> Monitoring Piping Overfill <br /> Panel: Veeder-Root TLS-350 System: XPressurized Suction C Gravity Prevention: XMechanical ❑Audible/visual <br /> UST 5 6 7 <br /> - Product - -87-octane - --91-octane- ----DSL--- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - <br /> Operator: Zane Nimmo 8211269 ICC Exp. 3/3/2016 Violations: ❑M1-Release Detection XM2-Release Prevention G M3-Both <br /> Operator: Date: <br /> On Site Service ICC Exp Manufacturer's <br /> Technician: Zane Nimmo8211269 Date: '6/25/2015 Training: VR A28446 9/26/15; VMI#2072 1/30/15 <br /> VIOLATIONS <br /> # C1 C2 M Code Section HSC=California Health and Safety Code;CCR=California Code of Regulations <br /> C1 =Class 1 violation;C2=Class 2 violation;M=Minor violation <br /> �'',. � "� a;c-z 'fit=; ? ,., ,.'��:: s✓a; F��e`,R�1rteNi% .. m �,t~ ,��.'e„ ' :*'....a, ,.:..;.:t ,r. -�; <br /> 101 HSC 25284 No permit to operate <br /> 102 HSC 25404.5 Annual operating fees not paid <br /> 103 HSC 25284(a)(3) No written agreement between the person that the operating permit was issued to and the tank operator to <br /> monitor the tanks stem <br /> 104 HSC 25292.2 Current financial responsibility documents not on file with the Environmental Health Department(EHD) <br /> 105 CCR 2711 Current Unified Program Consolidated Forms not on file with the EHD(Facility and tank form) <br /> 106 CCR 2632(b) Monitoring Program(Monitoring&Response Plans)is not current or approved by the EHD <br /> 107 CCR 2632(d)(1)(C) Plot plan/site map not submitted or fails to completely show where monitoring is performed <br /> 108 CCR 2637 Secondary containment:(a)test not performed;(e)test report not submitted within 30 days;(f)test notification <br /> not provided to the EHD at least 48 hours prior to conducting thg test <br /> Monitoring equipment certification (a not performed annually;(d) est report not submitted within 30 days; <br /> 109 X CCR 2638 (e)test notification not provided to M EHD at least 48 hours pW to conducting an installation, repair, <br /> replacement,calibration,or certification <br /> 110 HSC 25291(f) Annual line leak detector test not performed (M1) <br /> 111 X HSC 25284.2 Annual spill containment testing not performed <br /> 112 CCR 2636(f)(4) Annual line tightness test not performed if positive shutdown or fail safe not present (M1) <br /> 113 CCR 2715(a) Failed to inform the EHD of a change of designated operator within 30 days <br /> 114 CCR 2715(b) Designated operator does not possess a current ICC CA UST System Operator certification <br /> 115 CCR 2660(k) Repair for tank or piping not tested for tightness after completion of the repair pursuant to (M2) <br /> ermit conditions <br /> 116 HSC 25292.5 Enhanced leak detection(ELD)testing not performed on a system located within 1000'of public well,or <br /> failures not repaired and retested <br /> 117 CCR 2661 Permit to repair UST system not obtained <br /> 118 HSC 25286(a) Operational permit not amended when UST storage and/or monitoring system changed <br /> 119 HSC 25298(b) Permit to temporarily close UST system not obtained <br /> 120 HSC 25298(c) Permit to close UST system not obtained <br /> ora � . <br /> n <br /> Maintenance&monitoring records not maintained 3 years,cathodic protection records for 6%years,written <br /> performance claims pertaining to release detection systems for 5 years,or records of repairs,linings,and <br /> 201 CCR 2712(b) upgrades for the life of the tank. Monitoring records include:(1)date and time of all monitoring or sampling; <br /> (2)monitoring equipment calibration and maintenance records;(3)results of any visual observations;(4) <br /> results of sample analysis performed a lab or in the field;(5)logs of all readings of gauges or other monitoring <br /> equipment, round water elevations,or other test results; 6 results of inventory readings and reconciliations <br /> 202 CCR 2712(i) Monitoring plan,response plan,and/or operating permit and all conditions not onsite <br /> Unauthorized release that:(c)did not escape secondary containment and cleaned up within eight hours (M1) <br /> 203 CCR 2650 was not recorded;(e)escaped secondary containment,not cleaned up after eight hours,or a sudden loss of <br /> product was not reported to the EHD within 24 hours <br /> Inspector: Received By: Title: <br /> Jeffrey Wong (209) 468-0335 <br /> EHD 23-02 Rev 04/19/12 P UST INSPECTION REPORT <br />