011 <br /> SAN JOAQUIN COUNTY 0 <br /> ENVIRONMENTAL HEALTH DEPARTMENT <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone:(209)468-3420 Fax: (209)468-3433 Web:www.smgov.org/ehd <br /> UNDERGROUND STORAGE TANK (UST) PROGRAM INSPECTION REPORT CONTINUED <br /> Facility Grewal's Gas & Liquor Address: 100 E. Fremont, Stockton Inspection Apr 16, 2014 <br /> Name: <br /> VIOLATIONS <br /> # C1 Code Section HSC=CA Health and SafetyCode;CFR=Code of Federal Regulations <br /> C2 M <br /> C1 =Class 1 violation;C2=Class 2 violation;M=Minor violation <br /> u IV on-Pres'sur)iect .iping`(continued}. �...' . <br /> _. . , : <br /> 702 CCR 2643(e) Biennial tightness test of gravity piping not performed(pre-January 1, 1984) (M1) <br /> 703 CCR 2643(d) Triennial line test for conventional suction piping not performed(pre January 1 1984) (M1) <br /> ., .., Raw, <br /> 999 1 10ther: See attached"Continuation—Official Inspection Report'for violation(s)not listed above. <br /> SUMMARY OF VIOLATIONS <br /> CLASS I, CLASS II, or MINOR-Notice to Comply) <br /> This is a Routine and Monitoring Certification inspection. The following is a Minor-Notice to Comply <br /> violation: 109, 109/305, 111/311 <br /> 109. The a test report of the annual monitoring system certification, leak detector testing, and spill <br /> container testing performed on April 17, 2013 was submitted to the EHD on May 21, 2013, and a <br /> duplicate of the same report on May 22, 2013. A copy of the test report must be submitted within 30 <br /> days of the tests. Immediately begin submitting a copy of the report of test within 30 days to the EHD. <br /> 109 & 305. The UDC sump sensors were not tested due to lack of access, therefore continuous <br /> monitoring of the tank system could not be verified. These tests are required once every 12 months, <br /> that all monitoring equipment shall be maintained to activate an audible and visual alarm or stop the flow <br /> of product at the dispenser when it detects a leak. Immediately schedule these tests and provide 48 <br /> hours notification to the EHD. Please be aware that a follow up inspection will be charged at our current <br /> hourly rate. <br /> 111 & 311. The line leak detectors were not tested due to lack of access. All line leak detectors shall be <br /> capable of detecting a 3-gallon per hour leak at 10 psi, and tests are required once every 12 months. <br /> Immediately have a properly licensed, trained, and certified contractor test the line leak detectors and <br /> notify EHD at least 48 hours in advance by April 30, 2014. Please be aware that a follow up inspection <br /> will be charged at our current hourly rate. <br /> NOTES <br /> The previously financial Responsibility and Chief Financial Officer letter were dated April 17, 2013; <br /> therefore still in effect today during this inspection. A new version of these document were provided to <br /> EHD during this inspection dated April 16, 2014. Financial Responsibility and Chief Financial Officer <br /> letter shall be submitted to EHD before the deadline, or uploaded to CERS website. <br /> ALL EHD F IME ASSOCIATED WITH FAILING TO COMPLY BY THE ABOVE NOTED DATES WILL BE BILLED AT THE CURRENT HOURLY RATE. <br /> T-"6'-' ILI IS SUBJECT TO REINSPECTION AT ANY TIME AT EHD'S CURRENT HOURLY RATE. <br /> Ins pe o. Received By: Title: <br /> FYA I <br /> E 23-02 ev 0 /12 age 3 UST INSPECTION REPORT <br />