Laserfiche WebLink
0 0 NECEIVcj) <br /> Appendix VI JUN 6 201; <br /> MONITORING SYSTEM CERTIFICATION <br /> For <br /> use By All Authority Cited: Chapter 6.7, Health and Safety Code;sChaptedictions 1r 16,�Div cion 3, cts <br /> Titlethe State of r23,California Code onia f MT 1-,y <br /> This form must be used to document testing and servicing of monitoring equipment.A separate certification or report must be prepared for <br /> each monitoring system control panel by the technician who performs the work.A copy of this form must be provided to the tank system <br /> owner/operator.The owner/operator must submit a copy of this form to the local agency regulating UST systems within 30 days of test date. <br /> A. General Information <br /> Facility Name: GREWALS GAS AND LIQUOR Bldg.No.: <br /> Site Address: 4100 E FREMONT STREET City: STOCKTON CA Zip: 95215 <br /> Facility Contact Person: RICK Contact Phone No.: (209)487-0480 <br /> Make/Model of Monitoring System: VEEDER ROOT TLS 350 Date of Testing/Servicing: 04-06-17 <br /> B. Inventory of Equipment Tested/Certified <br /> Check the appropriate boxes to indicatespecific equipment inspected/serviced: <br /> Tank ID: 87 Tank ID: 91 <br /> ® In-Tank Gauging Probe. Model: MAG 2 ® In-Tank Gauging Probe. Model: MAG 2 <br /> ® Annular Space or Vault Sensor. Model: 420 ® Annular Space or Vault Sensor. Model: 420 SPLIT W DIE <br /> ® Piping Sump/Trench Sensor(s). Model: 208 ® Piping Sump/Trench Sensor(s). Model: 208 <br /> ❑ Fill Sump Sensor(s). Model: ❑ Fill Sump Sensor(s). Model: <br /> ❑ Mechanical Line Leak Detector. Model: ❑ Mechanical Line Leak Detector. Model: <br /> ® Electronic Line Leak Detector. Model: FE PETRO ® Electronic Line Leak Detector. Model: PLLD <br /> ® Tank Overfill/High-Level Sensor. Model: FLAPPER ® Tank Overfill/High-Level Sensor. Model: FLAPPER <br /> ❑ Other(specify equipment type and model in Section E on Page 2). ❑ Other(specify equipment type and model in Section E on Page 2). <br /> Tank ID: NA Tank ID: DIE <br /> ❑ In-Tank Gauging Probe. Model: ® In-Tank Gauging Probe. Model: MAG 1 <br /> ❑ Annular Space or Vault Sensor. Model: ® Annular Space or Vault Sensor. Model: 420 SPLIT W 91 <br /> ❑ Piping Sump/Trench Sensor(s). Model: ® Piping Sump/Trench Sensor(s). Model: 208 <br /> ❑ Fill Sump Sensor(s). Model: ❑ Fill Sump Sensor(s). Model: <br /> ❑ Mechanical Line Leak Detector. Model: ® Mechanical Line Leak Detector. Model: 99 LD 2000 <br /> ❑ Electronic Line Leak Detector. Model: ❑ Electronic Line Leak Detector. Model: <br /> ❑ Tank Overfill/High-Level Sensor. Model: ® Tank Overfill/High-Level Sensor. Model: FLAPPER <br /> ❑ Other(specify equipment type and model in Section E on Page 2). ❑ Other(specify equipment type and model in Section E on Page 2). <br /> Dispenser ID: 1-2 Dispenser ID: 3-4 <br /> ® Dispenser Containment Sensor(s). Model: 208 ® Dispenser Containment Sensor(s). Model: 208 <br /> ® Shear Valve(s). ® Shear Valve(s). <br /> ❑ Dispenser Containment Float(s)and Chain(s). ❑ Dispenser Containment Float(s)and Chain(s). <br /> Dispenser ID: 5-6 Dispenser ID: 7-8 <br /> ® Dispenser Containment Sensor(s). Model: 208 ® Dispenser Containment Sensor(s). Model: 208 <br /> ® Shear Valve(s). ® Shear Valve(s). <br /> ❑ Dispenser Containment Float(s)and Chain(s). ❑ Dispenser Containment Float(s)and Chain(s). <br /> Dispenser ID: NA Dispenser ID: NA <br /> ❑ Dispenser Containment <br /> ❑ Dispenser Containment Sensor(s). Model: Sensor(s). Model: <br /> ❑ Shear Valve(s). ❑Shear Valve(s). <br /> ❑ Dispenser Containment Float(s)and Chain(s). ❑Dispenser Containment Float(s)and Chain(s). <br /> *If the facility contains more tanks or dispensers,copy this form. Include information for every tank and dispenser at the facility. <br /> C.Certification-I certify that the equipment identified in this document was inspected/serviced in accordance with the manufacturers' <br /> guidelines.Attached to this Certification is information(e.g.manufacturers'checklists)necessary to verify that this information is correct <br /> and a Plot Plan showing the layout of monitoring equipment.For any equipment capable of generating such reports,1 have also attached a <br /> copy of the report;(check all that apply): ®System set-up ®Alarm history report <br /> Technician Name(print): FELIX RAMIREZ Signature. fir" > <br /> Certification No.: 5273934-UT License No: 08-1740 <br /> Testing Company Name: AFFORDA-TEST Phone No. (209)744-0113 <br /> Testing Company Address: 416 2nd STREET GALT,CA 95632 Date of Testing/Servicing: 04-06-17 <br /> Monitoring System Certification Page 1 of 4 2/21/07 <br /> S� C <br />