My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2013-2018
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
F
>
FREMONT
>
4100
>
2300 - Underground Storage Tank Program
>
PR0231574
>
COMPLIANCE INFO_2013-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/14/2023 4:12:45 PM
Creation date
6/23/2020 6:50:11 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2013-2018
RECORD_ID
PR0231574
PE
2361
FACILITY_ID
FA0002123
FACILITY_NAME
GREWALS GAS & LIQUOR*
STREET_NUMBER
4100
Direction
E
STREET_NAME
FREMONT
STREET_TYPE
ST
City
STOCKTON
Zip
95215
APN
14333046
CURRENT_STATUS
01
SITE_LOCATION
4100 E FREMONT ST
P_LOCATION
99
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231574_4100 E FREMONT_2013-2018.tif
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
172
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Fj (-;E,-, V LU <br /> ' j U N '� 6 AWRCB,January 2006 <br /> Spill Bucket Testing Report Form <br /> This form is intended for use by contractors performing annual testing of UST spill con )#& I t corm and <br /> printouts from tests (f applicable), should be provided to the facility owner/operator for submitt _ 0, _ latory agency. <br /> 1.FACILITY INFORMATION <br /> Facility Name: GREWALS GAS AND LIQUOR Date of Testing: 04-6-17 <br /> Facility Address: 4100 EAST FREMONT ST STOCKTON CA <br /> Facility Contact: RICK Phone: 209-487-0480 <br /> Date Local Agency Was Notified of Testing:03-20-17 <br /> Name of Local Agency Inspector(fpresent during testing): SAN JOAQUIN CO VICKI <br /> 2.TESTING CONTRACTOR INFORMATION <br /> Company Name: AFFORDA TEST 416 211 Street Galt,CA 95632 (209)744-0112 Fax:(209)744-0116 <br /> Technician Conducting Test: ❑Ed Stearns ❑ Zane A.Nimmo ❑ David A. Winkler ® Felix G.Ramirez <br /> 8184188 5263322-UT 5263373-UT 5273934-UT <br /> Credentials': ® ICC Service Tech. ® SWRCB Tank Tester <br /> 3. SPILL BUCKET TESTING INFORMATION <br /> Test Method Used: ®Hydrostatic ❑ Vacuum ❑ Other <br /> Test Equipment Used: TAPE/H2O Equipment Resolution: 1/16 <br /> Identify Spill Bucket(By Tank 1 87 2 91 3 DIESEL 4 <br /> Number, Stored Product, etc.) <br /> ® Direct Bury ® Direct Bury ®Direct Bury ❑Direct Bury <br /> Bucket Installation Type: ❑Contained in ❑ Contained in <br /> ❑ Contained in Sump El Contained in Sump Sump Sum <br /> Bucket Diameter: 11 11 11 <br /> Bucket Depth: 11 12 15 <br /> Wait time between applying <br /> vacuum/water and start of test: <br /> Test Start Time(Ti): 910 910 910 <br /> Initial Reading(Ri): 11 12 15 <br /> Test End Time(TF): 1010 1010 1010 <br /> Final Reading(RF): 10 1/2 12 15 <br /> Test Duration(TF—Ti): I HOUR 1 HOUR 1 HOUR <br /> Change in Reading(RF-RI): 1/2 INCH 0 0 <br /> Pass/Fail Threshold or <br /> Criteria: <br /> Test Result: ❑ Pass 0 Fail 10 Pass ❑Fail ® Pass ❑Fail ❑ Pass ❑ Fail i <br /> Comments— (include information on repairs made prior to testing, and recommended follow-up for failed tests) <br /> OPW BUCKETS <br /> 87 BUCKETS DOES NOT HAVE 5 GALLON CAPACITY-REPAIR AND RETEST NEEDED <br /> 91 AND DIESEL BUCKET HOLD 5 GALLON CAPACITY <br /> CERTIFICATION OF TECHNICIAN RESPONSIBLE FOR CONDUCTING THIS TESTING <br /> I hereby certify that all the information contained in this report is true,accurate,and in full compliance with legal requirements. <br /> Technician's Signature: Date:04-06-17 <br /> ' State laws and regulations do not currently require testing to be performed by a qualified contractor.However,local requirements <br /> may be more stringent. <br />
The URL can be used to link to this page
Your browser does not support the video tag.