My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2013-2018
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
N
>
99 (STATE ROUTE 99)
>
25651
>
2300 - Underground Storage Tank Program
>
PR0231628
>
COMPLIANCE INFO_2013-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/19/2024 1:51:14 PM
Creation date
6/23/2020 6:50:32 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2013-2018
RECORD_ID
PR0231628
PE
2361
FACILITY_ID
FA0003835
FACILITY_NAME
SMK CHEVRON
STREET_NUMBER
25651
Direction
N
STREET_NAME
STATE ROUTE 99
City
ACAMPO
Zip
95220
APN
00514120
CURRENT_STATUS
01
SITE_LOCATION
25651 N HWY 99
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231628_25651 N HWY 99_2013-2018.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
201
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
NIFIED PROGRAM CONSOLIDATED FO <br /> UNDERGROUND STORAGE TANK <br /> MONITORING PLAN- Page I of 2) <br /> TYPE OF ACTION MI.NEW PLAN ❑ 2.CHANGE OF INFORMATION 490-1 <br /> PLAN TYPE 1.MONITORING IS IDENTICAL FOR ALL USTs AT THIS FACILITY. 490-2 <br /> (Check one item only) ❑ 2.THIS PLAN COVERS ONLY THE FOLLOWING UST SYSTEM(S)- <br /> L AGILITY INFOR.MATIUN <br /> FACILITY ID#(Agency Use Only) I I Ia - 1 <br /> BUSINESS NAME(Same as FACILITY NAME) 3 <br /> BUSINESS SITE ADDRESS Zs�s ► `f / 103. CITY �o c '22,� 104. <br /> H.EQUIPMENT TE$ONG AND PREVENTIVE MAINTENANCE <br /> Testing,preventive maintenance,and calibration of monitoring equipment(e.g.,sensors,probes,line leak detectors,etc.)must be performed at the frequency <br /> specified by the equipment manufacturers'instructions,or annually,whichever is more frequent,and that such work must be performed by qualified personnel. <br /> (23 CCR§2632,2634,2638,2641) <br /> -1.ANNUALLY 490-3a <br /> MONITORING EQUIPMENT IS SERVICED 99.OTER( ecify): <br /> 490-3b <br /> III:MONITORING LOCATIONS <br /> ❑1.NEW SITE PLOT PLAN/MAP SUBMITTED WITH THIS PLAN. ❑2.SITE PLOT PLAN/MAP PREVIOUSLY SUBMITTED. (23 CCR§2632, <br /> 2634)49o4 <br /> IV.TANK I IOl 1I O T+G,IS RI(}Ii111 D USING TTIE FOLLO ING THOD( }: <br /> 1.CONTINUOUS ELECTRONIC TANK MONITORING OF ANNULAR(INTERSTITIAL)SPACE(S)OR SECONDARY CONTAINMENT 490-5 <br /> VAULT(S)WITH AUDIBLE AND VISUAL ALARMS. (23 CCR§2632,2634) <br /> SECONDARY CONTAINMENT IS: a.DRY ❑ b.LIQUID FILLED ❑ c.PRESSURIZED ❑d.UNDER VACUUM 490-6 <br /> - - - -- - - - - --------------------------------- - - ---------- <br /> 490-7. 490-8 <br /> PANEL MANUFACTURER: T MODEL#: (.S <br /> -- ------- - - --- -------- -- -- - - ------- ---1- -- -L#- -- - - - - - -/-, - - - - - <br /> LEAK SENSOR MANUFACTURER: (,� W ago 9. 1 MODEL#(S): 7 7 490-,0 <br /> ❑ 2.AUTOMATIC TANK GAUGING(ATG)SYSTEM USED TO MONITOR SINGLE WALL TANK(S).(23 CCR§2643) 90-I I <br /> PANEL MANUFACTURER: 490-12. MODEL#: 490-13 <br /> --- - -------- - - - ----------------------------------------------------------- ----------- -- -- - - - - - -- - - - ------------------------------------------- <br /> IN-TANK PROBE MANUFACTURER: 490-14. MODEL#(S): 490-15 <br /> - - - - - ----------------------------------- - ----------------------------- - -- - - - - -- - - -- - - - - - - - - - -- - - - -- --------------- - - - - - - - <br /> LEAK TEST FREQUENCY: ❑ a.CONTINUOUS ❑ b.DAILY/NIGHTLY ❑ c.WEEKLY 490-16 <br /> ❑ d.MONTHLY El e.OTHER(Specify): 490-17 <br /> . --------------------------------------- - -- - ------- --- --------- --- --------- --------- ------- -------- ------ <br /> PROGRAMMED TESTS: ❑ a.0.1 h. ❑ b.0.2 h. ❑ c.OTHER490-18 <br /> g�P� g�P• (Specify): a9oa9 <br /> ❑ 3.MONTHLY STATISTICAL INVENTORY RECONCILIATION(23 CCR§2646.1): 490-20 <br /> ❑ 4.WEEKLY MANUAL TANK GAUGING(MTG)(23 CCR§2645). TESTING PERIOD: Ela.36 HOURS Elb.60 HOURS 4 <br /> 90-21 <br /> F5.TANK INTEGRITY TESTING(23 CCR§2643.1): a9o- <br /> TEST FREQUENCY: a.ANNUALLY Elb.BIENNIALLY Elc.OTHERS eci 90-2a <br /> ( p �)' 490-25 <br /> ❑99.OTHER (Specify): 490-26 <br /> 490-27 <br /> V.PIPE-MUNITORINQ;I PER*bAMt ?USING tHE FOLLOWING METHODS)(Check all that ioPlY) <br /> 19 1.CONTINUOUS MONITORING OF PIPE/PIPING SUMP(S)AND OTHER SECONDARY CONTAINMENT WITH AUDIBLE AND 490-28 <br /> VISUAL ALARMS. (23 CCR§2636) <br /> SECONDARY CONTAINMENT IS:M...DRY ❑b.LIQUID FILLED ❑c.PRESSURIZED ❑d.UNDER VACUUM 490-29 <br /> ----------------------------------y-- -am------------�----------------y-g-N---'-- - -----------49-0--3 <br /> -0 <br /> --- - ---------------L----------- <br /> - -- <br /> - - 490-31 <br /> PANEL MANUFACTURER - MODEL#: <br /> - <br /> _ <br /> LEAK SENSOR_MANUFACTURER: �i+ �- -49032 L MODEL#(S)_ 490 33 <br /> PIPING LEAK ALARM TRIGGERS AUTOMATIC PUMP(i.e.,TURBINE)SHUTDOWN. Ka.YES ❑b.NO 490-34 <br /> FAILURE/DISCONNECTION OF THE MONITORING SYSTEM TRIGGERS AUTOMATIC PUMP SHUTDOWN. t9a.YES ❑b.NO 490-35 <br /> ❑ 2.MECHANICAL LINE LEAK DETECTOR(MLLD)THAT ROUTINELY PERFORMS 3.0 g.p.h.LEAK TESTS AND RESTRICTS OR SHUTS OFF <br /> PRODUCT FLOW WHEN A LEAK IS DETECTED 23 CCR 2636 490-36 <br /> MLLD MANUFACTURER(S): 490-37 MODEL#(S): 490-38 <br /> 3.ELECTRONIC LINE LEAK DETECTOR(ELLD)THAT ROUTINELY PERFORMS 3.0 g.p.h.LEAK TESTS (23 CCR§2636) 490-39 <br /> ---------------------------- - --- -- - <br /> �-------------------490-40 -�------------------- - <br /> - --- ELLD MANUFACTURER(S) - ,.�E�- - - )-MODEL#(S)-- - - ---------------------------------------------- <br /> PROGRAMMED <br /> - - -- <br /> - - - - - - - - -® - ---------------- -- <br /> PROGRAMMED IN LINE LEAK TEST: ❑ 1.MINIMUM MONTHLY 0.2 g.p.h. ❑ 2.MINIMUM ANNUAL 0.1 g.p.h. 490-42 <br /> ELLD D N OF A PIPING LEAK TRIGGERS AUTOMATIC PUMP SHUTDOWN. a.YES ❑b.NO 490-43 <br /> ELLD AILD ISCONNECTION TRIGGERS AUTOMATIC PUMP SHUTDOWN. a.YES ❑b.NO 49044 <br /> 4.PIPE INTEGRITY TESTING 490-45 <br /> TEST FREQUENCY ANNUALLY ❑ b.EVERY 3 YEARS ❑ c.OTHER(Specify) 490-46490-47 <br /> 5.VISUAL PIPE MONITORING. 49048 <br /> FREQUENCY N a.DAILY ❑ b.WEEKLY ❑c.MIN.MONTHLY&EACH TIME SYSTEM OPERATED* 49049 <br /> *Allowed for monitorin of unburied emergency enerator fuel piping only per HSC§25281,5(b)(3 <br /> ❑ 6.SUCTION PIPING MEETS EXEMPTION CRITERIA[23 CCR§2636(a)(3)1. 490-50 <br /> ❑ 7.NO REGULATED PIPING PER HEALTH AND SAFETY CODE,DIVISION 20,CHAPTER 6.7 IS CONNECTED TO THE TANK SYSTEM <br /> 490-51 <br /> E] 99.OTHER(Specify) 490-52 <br /> 490-53 <br /> UPCF UST-D(12/2007)1/4 <br />
The URL can be used to link to this page
Your browser does not support the video tag.