Laserfiche WebLink
L] <br />9 <br />SAN JOAQUIN COUNTY <br />ENVIRONMENTAL HEALTH DEPARTMENT <br />1868 East Hazelton Avenue, Stockton, California 95205-6232 <br />Telephone: (209) 468-3420 Fax: (209) 468-3433 Web: www.smgov.org/ehd <br />UNDERGROUND STORAGE TANK (UST) PROGRAM INSPECTION REPORT <br />Name: SMK Chevron ity <br />VIOLATIONS <br />Facility 25651 N Hwy 99 Acampo, CA 952 <br />Address: <br />osteon Jun 12, 2014 <br />Facility <br />Tony Singh <br />M <br />Code Section <br />Title: <br />operator <br />C1 = Class 1 violation; C2.= Class 2 violation; M = Minor violation <br />M) 333-1740 <br />Contact: <br />101 HSC 25284 <br />No permit to operate <br />102 HSC 25404.5 <br />Annual operating fees not paid <br />103 HSC 25284(a)(3) <br />Inspection <br />Type: X Routine X Monitoring System <br />Certification i i Installation ❑ Complaint - I[W. <br />❑ Other. <br />(Authority HSC 25289) <br />Ton Singh <br />y g <br />operator <br />Consentfor. XInspection XSampling XPhotos <br />107 CCR 2632(d)(1)(C) <br />Grantedby: <br />Title: <br />Monitoring <br />Panel: Veeder-Root TLS -350 <br />Piping <br />System: <br />System: <br />D4 Pressurized E Suction Li Gravity <br />Overfill <br />prevention: <br />t <br />x Mechanical 7 Audiblelvisual <br />usT <br />78 <br />112 CCR 2636(f)(4) <br />9 <br />113 CCR 2715(a) <br />- -- - - - - <br />------------- <br />-------------- <br />-------------- <br />Repair for tank or piping not tested for tightness after completion of the repair pursuant to (M2) <br />permit conditions <br />- - - - - ---------------- <br />Enhanced leak detection (ELD) testing not performed on a system located within 1000' of public well, or <br />failures not re aired and retested <br />-Product <br />f8_7_,­ctane - <br />1____91 octane -- <br />--- <br />diesel <br />-- <br />Permit to temporarily close UST system not obtained <br />120 HSG 25298(c) <br />Permit to close UST system not obtained <br />On Site Records <br />201 CCR 2712(b) <br />Maintenance & monitoring records not maintained 3 years, cathodic protection records for 6'/. years, written <br />performance claims pertaining to release detection systems for 5 years, or records of repairs, linings, and <br />upgrades for the life of the tank. Monitoring records include: (1) date and time of all monitoring or sampling; <br />(2) monitoring equipment calibration and maintenance records; (3) results of any visual observations; (4) <br />results of sample analysis performed a lab or in the field; (5) logs of all readings of gauges or other monitoring <br />e ui ment, around water elevations, or other test results; 6 results of inventory readings and reconciliations <br />Designated <br />Alex Jabarri <br />ICC : <br />10-6-14 <br />Violations: ❑ M1 -Release Detection <br />❑ M2 -Release Prevention I M3 -Both <br />On Site Service <br />Felix Ramirez <br />ICC Exp. <br />Manufacturer's <br />12-6-14 swrcb 5-31-17, yr 6-25-14, vmi 11-12-15 <br />Technician: <br />Date: <br />Training: <br />Inspecim <br />AMYffli R. %U"152 <br />� r. <br />tHu z3-uz mev u4lh9J1z <br />rage .1 <br />VIOLATIONS <br /># <br />C1 <br />C2 <br />M <br />Code Section <br />HSC = California Health and Safety Code; CCR = California Code of Regulations <br />C1 = Class 1 violation; C2.= Class 2 violation; M = Minor violation <br />File Review <br />101 HSC 25284 <br />No permit to operate <br />102 HSC 25404.5 <br />Annual operating fees not paid <br />103 HSC 25284(a)(3) <br />No written agreement between the person that the operating permit was issued to and the tank operator to <br />monitor the tanks stem <br />104 HSC 25292.2 <br />Current financial responsibility documents not on file with the Environmental Health Department (EHD) <br />105 CCR 2711 <br />Current Unified Program Consolidated Forms not on file with the EHD (Facility and tank form) <br />106 CCR 2632(b) <br />Monitoring Program (Monitoring & Response Plans) is not current or approved by the EHD <br />107 CCR 2632(d)(1)(C) <br />Plot plan/site map not submitted or fails to completely show where monitoring is performed <br />108 CCR 2637 <br />Secondary containment: (a) test not performed; (e) test report not submitted within 30 days; (f) test notification <br />not provided to the EHD at least 48 hours prior to conducting the test <br />109 CCR 2638 <br />Monitoring equipment certification: (a) not performed annually; (d) test report not submitted within 30 days; <br />(e) test notification not provided to the EHD at least 48 hours prior to conducting an installation, repair, <br />replacement, calibration, or certification <br />110 HSC 25291(f) <br />Annual line leak detector test not performed (M7) <br />111 HSC 25284.2 <br />Annual spill containment testing not performed <br />112 CCR 2636(f)(4) <br />Annual line tightness test not performed if positive shutdown or fail safe not present (M7) <br />113 CCR 2715(a) <br />Failed to inform the EHD of a change of designated operator within 30 days <br />114 CCR 2715(b) <br />Designated operator does not possess a current ICC CA UST System Operator certification <br />115 CCR 2660(k) <br />Repair for tank or piping not tested for tightness after completion of the repair pursuant to (M2) <br />permit conditions <br />116 HSC 25292.5 <br />Enhanced leak detection (ELD) testing not performed on a system located within 1000' of public well, or <br />failures not re aired and retested <br />117 CCR 2661 <br />Permit to repair UST system not obtained <br />118 HSC 25286(a) <br />Operational permit not amended when UST storage and/or monitoring system changed <br />119 HSC 25298(b) <br />Permit to temporarily close UST system not obtained <br />120 HSG 25298(c) <br />Permit to close UST system not obtained <br />On Site Records <br />201 CCR 2712(b) <br />Maintenance & monitoring records not maintained 3 years, cathodic protection records for 6'/. years, written <br />performance claims pertaining to release detection systems for 5 years, or records of repairs, linings, and <br />upgrades for the life of the tank. Monitoring records include: (1) date and time of all monitoring or sampling; <br />(2) monitoring equipment calibration and maintenance records; (3) results of any visual observations; (4) <br />results of sample analysis performed a lab or in the field; (5) logs of all readings of gauges or other monitoring <br />e ui ment, around water elevations, or other test results; 6 results of inventory readings and reconciliations <br />202 CCR 2712(i) <br />Monitoring plan, response plan, and/or operating permit and all conditions not onsite <br />203 CCR 2650 <br />Unauthorized release that: (c) did not escape secondary containment and cleaned up within eight hours (M7) <br />was not recorded; (e) escaped secondary containment, not cleaned up after eight hours, or a sudden loss of <br />product was not reported to the EHD within 24 hours <br />Inspecim <br />AMYffli R. %U"152 <br />� r. <br />tHu z3-uz mev u4lh9J1z <br />rage .1 <br />