Laserfiche WebLink
r RECEIVED <br /> Appendix VI <br /> MONITORING SYSTEM CERTIFICATION NENTPL <br /> For Use B All Jurisdictions Within the State of California b �' � <br /> Authority Cited:Chapter 6.7,Health and Safety Code; Chapter 16, Division 3,Title 23,California Code of pi<ajji.Q ?S T T <br /> This form must be used to document testing and servicing of monitoring equipment.A separate certification or report must be prepared for <br /> each monitoring system control panel by the technician who performs the work.A copy of this form must be provided to the tank system <br /> owner/operator.The owner/operator must submit a copy of this form to the local agency regulating UST systems within 30 days of test date. <br /> A. General Information <br /> Facility Name: COLLIER ROAD CHEVRON Bldg.No.: <br /> Site Address: 25651 N. HIGHWAY 99 city: ACAMPO zip: 95220 <br /> Facility Contact Person: Contact Phone No.: ( ) <br /> Make/Model of Monitoring System: VEEDER ROOT TLS-350 Date of Testing/Servicing: 6/5/2018 <br /> B. Inventory of Equipment Tested/Certified <br /> Check the appropriate boxes to indicatespecific a ui ment ins ected/serviced: <br /> Tank ID: 87 OCT Tank Size: 12 K Tank ID: 91 OCT Tank Size: 12 K <br /> N In-Tank Gauging Probe. Model: M A G 7 N In-Tank Gauging Probe. Model: M A G I <br /> N Annular Space or Vault Sensor. Model: 4 0 9 N Annular Space or Vault Sensor. Model: 4 0 9 <br /> N Piping Sump/Trench Sensor(s). Model: 2 0 8 N Piping Sump/Trench Sensor(s). Model: 2 0 8 <br /> N Fill Sump Sensor(s). Model: 2 0 8 ® Fill Sump Sensor(s). Model: 2 0 8 <br /> ❑ Mechanical Line Leak Detector. Model: ❑ Mechanical Line Leak Detector. Model: <br /> N Electronic Line Leak Detector. Model: P L L D - 8 4 8 4 N Electronic Line Leak Detector. Model: P L L D - 8 4 8 4 <br /> ❑ Tank Overfill/High-Level Sensor. Model: ❑ Tank Overfill/High-Level Sensor. Model: <br /> ❑ Other(specify equipment type and model in Section E on Page 2). ❑ Other(specify equipment type and model in Section E on Page 2). <br /> Tank ID: DIESEL Tank Size: 12 K Tank ID: Tank Size: <br /> N In-Tank Gauging Probe. Model: M A G I ❑ In-Tank Gauging Probe. Model: <br /> N Annular Space or Vault Sensor. Model: 4 0 9 ❑ Annular Space or Vault Sensor. Model: <br /> N Piping Sump/Trench Sensor(s). Model: 2 0 8 ❑ Piping Sump/Trench Sensor(s). Model: <br /> N Fill Sump Sensor(s). Model: 2 0 8 ❑ Fill Sump Sensor(s). Model: <br /> ❑ Mechanical Line Leak Detector. Model: ❑ Mechanical Line Leak Detector. Model: <br /> N Electronic Line Leak Detector. Model: P L L D - 8 4 8 4 ❑ Electronic Line Leak Detector. Model: <br /> ❑ Tank Overfill/High-Level Sensor. Model: ❑ Tank Overfill/High-Level Sensor. Model: <br /> ❑ Other(specify equipment type and model in Section E on Page 2). ❑ Other(specify equipment type and model in Section E on Page 2). <br /> Dispenser ID: I / 2 Dispenser ID: 3 / 4 <br /> N Dispenser Containment Sensor(s). Model: 2 0 8 N Dispenser Containment Sensor(s). Model: 2 0 8 <br /> N Shear Valve(s). N Shear Valve(s). <br /> ❑ Dispenser Containment Float(s)and Chain(s). ❑ Dispenser Containment Float(s)and Chain(s). <br /> Dispenser ID: 5 / 6 Dispenser ID: 7 / 8 <br /> N Dispenser Containment Sensor(s). Model: 2 0 8 N Dispenser Containment Sensor(s). Model: 2 0 8 <br /> N Shear Valve(s). N Shear Valve(s). <br /> ❑ Dispenser Containment Float(s)and Chain(s). ❑ Dispenser Containment Float(s)and Chain(s). <br /> Dispenser ID: 9 / 10 Dispenser ID: 11 / 12 <br /> N Dispenser Containment Sensor(s). Model: 2 0 8 N Dispenser Containment Sensor(s). Model: 2 0 8 <br /> N Shear Valve(s). N Shear Valve(s). <br /> ❑ Dispenser Containment Float(s)and Chain(s). ❑ Dispenser Containment Float(s)and Chain(s). <br /> 'If the facility contains more tanks or dispensers,copy this form. Include information for every tank and dispenser at the facility. <br /> C.Certification-I certify that the equipment identified in this document was inspected/serviced in accordance with the manufacturers' <br /> guidelines.Attached to this Certification is information(e.g.manufacturers'checklists)necessary to verify that this information is correct <br /> and a Plot Plan showing the layout of monitoring equipment.For any equipment capable of generating such reports,I have also attached a <br /> copy of the report;(check all that apply): N System set-up N Alarm history report <br /> Technician Name(print): ZANE NIMMO Signature: <br /> Certification No.: A28446 License No: 04-1676 <br /> Testing Company Name: AFFORDA-TEST Phone No. (209)744-0112 <br /> Testing Company Address: 416 2nd STREET GALT,CA 95632 Date of Testing/Servicing: 6/5/2018 <br /> Monitoring System Certification Page 1 of 4 2/21/07 <br />