Laserfiche WebLink
Rf D <br /> SWRCB,January 2002 J f,', 9. 2 t'D ge of <br /> 9. FILL RISER CONTAINMENT SUMP TESTING <br /> Facility is Not Equipped With Fill Riser Containment Sumps E <br /> Fill Riser Containment Sumps are Present,but were Not Tested l r7l,Q , I SNP e <br /> Test Method Developed By: Sump Manufacturer Industry Standard X Professional Engineer <br /> Other(Specify) <br /> Test Method Used: 1 Pressure Vacuum X Hydrostatic <br /> I �Other(Specify) <br /> Test Equipment Used: Caldwell Level Change Indicator Equipment Resolution: .002 <br /> Fill Sump#1-Diesel Fill Sump#2-91 Fill Sump#3-87 Fill Sump# <br /> -Sump Diameter: 42" 42" 42" <br /> Sump Depth: 71" 72" 67" <br /> Height from Tank Top to Top of 21" 23" 19" <br /> Highest Piping Penetration: <br /> Height from Tank Top to Lowest 49" 49" 50" <br /> Electrical Penetration: <br /> Condition of sump prior to Dry Dry Dry <br /> testing: <br /> Portion of Sump Tested Water Level 23" Water Level 25" Water Level 21" <br /> Sump Material: Fiberglass Fiberglass Fiberglass <br /> Wait time between applying 5 Minutes 5 Minutes 5 Minutes <br /> water and starting test: <br /> Test Start Time: 9:37 10:22 11:07 <br /> Initial Reading (RI): .001 .001 .001 <br /> Test End Time: 10:07 10:52 11:37 <br /> Final Readin (RF): .001 .001 .001 <br /> Test Duration: 30 Minutes 30 Minutes 30 Minutes <br /> Chane in Reading (RF—RI): 0 0 0 <br /> Pass/Fail Threshold or Criteria: .005/30Minutes .005/30Minutes .005/30Minutes <br /> Test Result: Pass Pass Pass <br /> Is there a sensor in the sump? Yes Yes Yes <br /> Does the sensor alarm when <br /> either product or water is Yes Yes Yes <br /> detected? <br /> Was sensor removed for testing? Yes Yes Yes <br /> Was sensor properly replaced and Yes Yes Yes <br /> verified functional after testing? <br /> Comments—(include information on repairs made prior to testing, and recommended follow-up for failed tests) <br />