Laserfiche WebLink
RECEIVED <br />San Joaquin County <br />Environmental Health Department MXY <br />1868 East Hazelton Avenue, Stockton, California 95205-6232 <br />Telephone: (209) 468-3420 Fax: (209) 468-3433 Web: www.sjgov.org/ehd ONVIKINMENTAL <br />PF-MMIT/SERACES <br />Facility Name: Facility Phone: Date: <br />VERIZON BUSINESS MANTCA (915) 554-3300 April 19, 2017 <br />Facility Address: CERS ID: <br />2551 E LOUISE AVE, MANTECA, CA 95336 10181481 <br />Inspection Contact: <br />Jonathon Pekele <br />Title: <br />Manager <br />Phone: <br />(916) 439-6042 <br />Inspection Type: <br />ROUTINE INSPECTION - Operating Permit <br />Program: <br />r2361 - UST FACILITY <br />Consent For: <br />® Ins ection ® Photos ❑ Samples <br />Consent Given By: <br />David Smith, Service Technician <br />Service Technician Onsite: Exp. Date: <br />David Smith 06/07/2018 <br />Designated Operator: Exp. Date: <br />David Smith 05/07/2018 <br />Service Technician Manufacturer's Training: <br />Pneumacator, 05/08/18 <br />CCR = California Code of Regulations HSC = Health and Safety Code CFR = Code of Federal Regulations <br />V = Violation R = Repeat violation COS = Corrected on site during inspectio <br />�d9c <br />101 <br />HSC 25284 <br />No permit to operate <br />❑ V ❑ R ❑ COS <br />102 <br />HSC 25284(a)(3) <br />No written agreement between tank owner and tank operator to monitor the tank system <br />❑ V ❑ R ❑ COS <br />103 <br />HSC 25292.2 <br />Current financial responsibility documents not submitted <br />❑ V ❑ R ❑ COS <br />104 <br />CCR 2711 <br />UST operating permit application for facility and tank information not submitted or current <br />❑ V ❑ R ❑ COS <br />105 <br />CCR 2632(d)(1) <br />Failed to have an approved UST monitoring plan <br />❑ V ❑ R ❑ COS <br />106 <br />CCR 2632(d)(2) <br />Failed to have an approved UST response plan <br />❑ V ❑ R ❑ COS <br />107 <br />CCR 2632(d)(1)(C) <br />Plot plan/site map not submitted or failed to completely show where monitoring is performed <br />■ V ❑ R ❑ COS <br />108 <br />CCR 2637(f), 2638(e) <br />Failed to notify the EHD 48 hours prior to conducting testing <br />❑ V ❑ R ❑ COS <br />109 <br />CCR 2637 <br />Failed to test secondary containment <br />❑ V ❑ R ❑ COS <br />110 <br />CCR 2637(e) <br />Failed to submit secondary containment test report within 30 days <br />❑ V ❑ R ❑ COS <br />111 <br />CCR 2638(a) <br />Failed to test monitoring and leak detection equipment annually <br />❑ V ❑ R ❑ COS <br />112 <br />HSC 25284.2 <br />Failed to test spill containers annually <br />❑ V ❑ R ❑ COS <br />113 <br />CCR 2638(d) <br />Failed to submit monitoring system certification test report within 30 days <br />■ V ■ R ❑ COS <br />114 <br />CCR 2636(f) <br />Failed to perform 0.1 gph annual line test for pressurized piping without fail safe or shut down <br />❑ V ❑ R ❑ COS <br />115 <br />CCR 2715(a) <br />Failed to inform the EHD of designated operator identification or change within 30 days <br />❑ V ❑ R ❑ COS <br />116 <br />CCR 2715 <br />Designated operator, service tech or installer did not possess current ICC certification <br />❑ V ❑ R ❑ COS <br />117 <br />CCR 2663 <br />Failed to inspect a lined or repaired steel tank within 10 years of lining and every 5 years after <br />❑ V ❑ R ❑ COS <br />118 <br />CCR 2663 <br />Failed to submit tank lining certification within 30 days or to conduct proper tests <br />❑ V ❑ R ❑ COS <br />119 <br />HSC 25299 <br />Documents were falsified or misrepresented <br />❑ V ❑ R ❑ COS <br />120 <br />CCR 2635(d) <br />Failed to submit UST Certification of Installation/Modification <br />❑ V ❑ R ❑ COS <br />121 <br />CCR 2712(f) <br />Failed to submit a written response within 30 days of receiving an inspection report <br />❑ V ❑ R ❑ COS <br />122 <br />CCR 2631 G) <br />Failure to submit UST system component statement of compatibility for substance stored <br />❑ V ❑ R ❑ COS <br />201 <br />CCR 2712(b) <br />TO <br />Failed to maintain alarm logs and/or records of follow up actions <br />❑ V ❑ R ❑ COS <br />202 <br />CCR 2712(b) <br />Failed to maintain cathodic protection test records on site for at least 6 1/2 years <br />❑ V ❑ R ❑ COS <br />203 <br />CCR 2712(b) <br />Failed to maintain records of monitoring, repair, lining, and upgrades on site <br />❑ V ❑ R ❑ COS <br />Page 1 of 4 <br />