My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_1986-2005
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
T
>
TRACY
>
1420
>
2300 - Underground Storage Tank Program
>
PR0231736
>
COMPLIANCE INFO_1986-2005
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/15/2024 1:16:35 PM
Creation date
6/23/2020 6:50:58 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1986-2005
RECORD_ID
PR0231736
PE
2361
FACILITY_ID
FA0002562
FACILITY_NAME
Sutter Valley Hospitals dba Sutter Tracy Community Hospital
STREET_NUMBER
1420
Direction
N
STREET_NAME
TRACY
STREET_TYPE
Blvd
City
Tracy
Zip
95376
APN
233-081-01
CURRENT_STATUS
01
SITE_LOCATION
1420 N Tracy Blvd
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231736_1420 N TRACY_1986-2005.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
457
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
y �m <br /> UNDERGROUND STORAGE TANK <br /> RESPONSE PLAN -PAGE 2 <br /> VI. LEAK INTERCEPTION DETECTION SYSTEM <br /> This information is required only for motor vehicle fuel UST systems constructed per the Altemate Construction Requirements of3 Wh R ac�ount33,ang for yrainfall and <br /> Interception and Detection System(LIDS) does not meet the volumetric requirements of 23 CCR §2631(d)(I) through (5) (i.e., <br /> backfill material,the secondary containment volume is less than 100%of primary tank volume for a single UST;or in the case of multiple USTs in shared secondary <br /> containment,150%of the largest primary tank volume or 10%of aggregate primary tank volume,whichever is greater). <br /> ATTACH AN ADDITIONAL PAGE TO THIS PLAN CONTAINING THE FOLLOWING INFORMATION: <br /> ➢ The volume of the LIDS in relation to the volume of the primary container, <br /> ➢ The amount of time the LIDS shall provide containment related to the time between detection of an unauthorized release and cleanup of the leaked substance; <br /> ➢ The depth from the bottom of the LIDS to the highest anticipated level of groundwater; <br /> ➢ The nature of the unsaturated soils under the LIDS and their ability tq absorb contaminants or to allow movement of contaminants; <br /> ➢ The methods and scheduling for removal of all hazardous substances which may have been discharged from primary containment and are located in the <br /> unsaturated soils between the primag containment and ffoundwater,including the LIDS sump. <br /> VII. REPORTING AND RECORD KEEPING <br /> We will rport/record any overfill,spill,or unauthorized release from a UST system as indicated in this plan. <br /> Recordable Releases: Any unauthorized release from primary containment which the UST operator is able to clean up within eight(8)hours after the release was <br /> detected or should reasonably have been detected,and which does not escape from secondary containment,does not increase the hazard of fire or explosion,and does <br /> not cause any deterioration of secondary containment,must be recorded in the facility's monitoring records. Monitoring records must include: <br /> ➢ The UST operator's name and telephone number; <br /> A list of the types,quantities,and concentrations of hazardous substances released; <br /> ➢ A description of the actions taken to control and clean up the release; <br /> ➢ The method and location of disposal of the released hazardous substances,and whether a hazardous waste manifest was or will be used <br /> ➢ A description of actions taken to repair the UST and to prevent future releases; <br /> ➢ A description of the method used to reactivate interstitial monitoring after replacement or repair of primary containment. <br /> spill,or uauthorized inment(or primary <br /> if no <br /> ndary containment <br /> Reportable <br /> eReleases: <br /> es the hazard of fire ll, <br /> or explosionnor causes anyldetenoraease 'tion of secondary contain ent,ich escapes from secondary sa eportable release.cReportable rele ses acre also recordable. <br /> exists), <br /> Within 24 hours after a reportable release has been detected,or should have been detected,we will notify the local agency administering the UST program of the <br /> sary,or if required by <br /> release,investigate m the UST to prevent further immediate <br /> e eases or facilitate correctivelact action. If an em emergency exists,we wdhnootifylthe State Office of remaining <br /> mergetored ncy SeFv ces. will <br /> be removed <br /> Within five(5)working days of a reportable release,we will submit to the local agency a full written report containing all of the following information to the extent <br /> that the information is known at the time of filing the report: <br /> ➢ The UST owner's or operator's name and telephone number; <br /> ➢ A list of the types,quantities,and concentrations of hazardous materials released; <br /> ➢ The approximate date of the release; <br /> ➢ The date on which the release was discovered; <br /> ➢ The date on which the release was stopped; <br /> ➢ A description of actions taken to control and/or stop the release; <br /> ➢ A description of corrective and remedial actions,including investigations which were undertaken and will be conducted to determine the nature and extent o <br /> soil,ground water or surface water contamination due to the release; <br /> ➢ The method(s)of cleanup implemented to date,proposed cleanup actions,and a schedule for implementing the proposed actions; <br /> ➢ The method(s)and location(s)of disposal of released hazardous materials and any contaminated soils,groundwater,or surface water. <br /> ➢ Copies of any hazardous waste manifests used for off-site transport of hazardous wastes associated with clean-up activity; <br /> ➢ A description of proposed methods for any repair or replacement of UST system primary/secondary containment systems; <br /> ➢ A description of additional actions taken to prevent future releases. <br /> We will follow the reporting procedures described above if any of the following conditions occur: <br /> ➢ A recordable unauthorized release can not be cleaned up or is still under investigation within eight(8)hours of detection; <br /> ➢ Released hazardous substances are discovered at the UST site or in the surrounding area; <br /> ➢ Unusual operating conditions are observed,including erratic behavior of product dispensing equipment,sudden loss of product,or the unexplained presence of <br /> water in the tank,unless system equipment is found to be defective and is immediately repaired or replaced,and no leak has occurred; <br /> ➢ Monitoring results from UST system monitoring equipment/methods indicate that a release may have occurred,unless the monitoring equipment is found to be <br /> defective and is immediately repaired,recalibrated,or replaced,and additional monitoring does not confirm the initial results. <br /> Record Retention: Monitoring records and written reports fna unauthorized releases must be maintained on-site(or off-site at a readily available location,if approved <br /> by the local agency)for at least 3 years. Hazardous waste shipping/disposal records(e.g.,manifests)must be maintained for at least 3 years from the date of shipment. <br /> VIII. OWNER/OPERATOR TOR SIGNATURE <br /> CERTIFICATION:I certify that the information provided herein is true and accurate to the best of my knowledge. R70 <br /> OWNER/OPERATOR SIGNATURE DATE <br /> Res. OWNER/OPERATOR TITLE <br /> OWNER/OPERATOR NAME(print) <br /> Approved With Conditions ❑Disapproved <br /> (Agency Use Only) This plan has been reviewed and: Approved ❑ PP <br /> Date: <br /> Local Agency Signature: <br /> 06725/03 <br /> SJCEHD-c(06/03)-3/3 <br />
The URL can be used to link to this page
Your browser does not support the video tag.