Laserfiche WebLink
11000MM 1 .01 11, <br />UNDERGROUND STORAGE TANK <br />RESPONSE PLAN - PAGE 2 <br />VT..E�iK'cEP1`iQN AND DETEii� SYSTEM <br />This information is requited 4ttly for motor vehicle fuel UST systems constructed per the Alternate Construction Requirements of 23 CCR §2633, and only if the Leak <br />Interception and Detection System (LIDS) d= not meet the volumetric requirements of 23 CCR §2631(dXl) through (5) (i.e., when accounting for rainfall and <br />backfill material, the secondary containment volume is less than 10046 of primary tankk volume for a single UST; or in the case of multiple USTs in shared secondary <br />containment. 150% of the largest primary tank volume or 10% of aggregate primary tank volume, whichever is greater). <br />ATTACH AN ADDITIONAL PAGE TO THIS PLAN CONTAINING THE FOLLOWING INFORMATION: <br />➢ The volume of the LIDS in relation to the volume of the primary container; <br />➢ The amount of time the LIDS shall provide containment related to the time between detection of an unauthorized release and cleanup of the leaked substance; <br />A The depth from the bottom of the LIDS to the highest anticipated level of groundwater; <br />➢ The nature of the unsaturated soils under the LIDS and their ability to absmb contaminants or to allow movement of contaminants; <br />The methods and scheduling for removal of all hazardous substances which may have been discharged from primary containment and are located in the <br />unsaturated soils between the p6M containment and pndwatcr, including the LIDS sump. <br />VII. ;REPORTING AND RECORD KEEPING <br />We will report/record any overfill, spill, or unauthorized release from a UST system as indicated in this plan. <br />Recordable Releases: Any unauthorized release from primary containment which the UST operator is able to clean up within eight (8) hours after the release was <br />detected or should reasonably have been detected, and which does not escape from secondary containment, does no increase the hazard of fire or explosion, and does <br />not cause any deterioration of secondary containment, most be recorded in the facility's monitoring records. Monitoring records must include: <br />A The UST operator's name and telephone number; <br />A A list of the types, quantities, and concentrations of hazardous substances released; <br />A description of the actions taken to control and clean up the release; <br />The method and location of disposal of the released hazardous substances, and whether a hazardous waste manifest was or will be used; <br />A A description of actions taken to repair the UST and to prevent future releases; <br />A A description of the method used to reactivate interstitial monitoring after replacement or repair of primary containment. <br />Reportable Releases: Any overfill, spill, or unauthorized release which escapes from secondary containment (or primary containment if no secondary containment <br />exists), increases the hazard of fire or explosion, or causes any deterioration of secondary containment, is a reportable release. Reportable releases are also recordable. <br />Within 24 hours after a reportable release has been detected, or should have been detected, we will notify the local agency administering the UST program of the <br />release, investigate the release, and take immediate measures to stop the release. If necessary, or if required by the local agency, remaining stored product/waste will <br />be removed from the UST to prevent further releases or facilitate corrective action. If an emergency exists, we will notify the State Office of Emergency Services. <br />Within five (5) working days of a reportable release, we will submit to the local agency a full written report containing all of the following information to the extent <br />that the information is known at the time of filing the report: <br />A The UST owner's or operator's name and telephone number; <br />A A list of the types, quantities, and concentrations of hazardous materials released; <br />The approximate date of the release; <br />➢ The date on which the release was discovered; <br />The date on which the release was stopped; <br />A description of actions taken to control and/or stop the release; <br />A A description of corrective and remedial actions, including investigations which were undertaken and will be conducted to determine the nature and extent of soil, <br />ground water or surface water contamination due to the release; <br />➢ The method(s) of cleanup implemented to date, proposed cleanup actions, and a schedule for implementing the proposed actions; <br />A The method(s) and location(s) of disposal of released hazardous materials and any contaminated soils, groundwater, or surface water. <br />A Copies of any hazardous waste manifests used for off-site transport of hazardous wastes associated with clear-up activity; <br />A A description of proposed methods for any repair or replacement of UST system primary/secondary containment systems; <br />A description of additional actions taken to prevent future releases. <br />We will follow the reporting procedures described above if any of the following conditions occur: <br />A recordable unauthorized release can not be cleaned up or is still under investigation within eight (8) hours of detection; <br />D Released hazardous substances are discovered at the UST site or in the surrounding area; <br />A Unusual operating conditions are observed, including erratic behavior of product dispensing equipment, sudden lass of product, or the unexplained presence of <br />water in the tank, unless system equipment is found to be defective and is immediately repaired or replaced, and no leak has occurred; <br />A Monitoring results from UST system monitoring equipment/methods indicate that a release may have occurred, unless the monitoring equipment is found to be <br />defective and is immediately repaired, recalibrated, or replaced, and additional monitoring does not confirm the initial results. <br />Record Retention: Monitoring records and written repots of unauthorized releases must be maintained on-site (or off-site at a readily available location, if approved <br />by the local agency) for at least 3 years. hazardous waste shipping/disposal records (e.g., manifests) must be maintained for at least 3 years from the date of shipment. <br />VIII,- OWNERI®PERATOR. SIGNATURE <br />CERTIFICATION: I certify that the information provided had. is true and accurate to the best of my knowledge <br />OWNER/OPERA4'O NA. RE <br />DATE oto. <br />August 15,2W7 <br />OWNER/OPERA NAME (print) crit' <br />G� S/ ij <br />OWNER/QPERATOR TITS ares. <br />d <br />1 <br />sten il,)t <br />(Agency Use Only) This plan has been reviewed and; ❑ Approved ❑ Approved With Conditions ❑ Disapproved-/ <br />Local Agency Signature: Date: <br />hwfwrc-e (9/24/04) - 2/4 <br />