Laserfiche WebLink
Monitoring System Certification <br />Address: J110 W. Turner Rd. Lodi 95242 <br />D. Results of Testing/Servicing <br />Software Version Installed: 127.04 <br />Complete the fol owina checklist: <br />Service Date: 06/17/2009 <br />® Yes ❑ No* <br />Is the audible alarm operational? <br />® Yes ❑ No* <br />Is the visual alarm operational? <br />® Yes ❑ No* <br />Were all the sensors visually inspected, functionally tested, and cofirmed operational? <br />® Yes ❑ No* <br />Were all sensors installed at lowest point of secondary containment and positioned so that other <br />equipment will not interfere with their proper operation? <br />® Yes ❑ No* <br />If alarms are relayed to a remote monitoring station, is all communications equipment (e.g. modem) <br />operational? <br />❑ N/A <br />❑ Yes ❑ No* <br />For pressurized piping systems, does the turbine automatically shut down if the piping secondary <br />containment monitoring system detects a leak, fails to operate, or is electrically disconnected? <br />If yes: which sensors <br />initiate positive shut- ❑ Sump/Trench Sensors ❑ Dispenser Containment Sensors <br />® N/A <br />down?: <br />Did you confirm positive shut -down due to leaks and sensor failure/disconnection? ❑ Yes ❑ No <br />❑ Yes ❑ No* <br />For tank systems that utilize the monitoring system as the primary tank overfill warning device (i.e. no <br />mechanical ovefill prevention valve is installed), is the overfill warning alarm visible and audible at the <br />® N/A <br />tank fill point(s) and operating property?lf so, at what percent of tank capacity does the alarm trigger?: <br />11 Yes* ®No <br />Was any monitoring equipment replaced? If yes, identify specific sensors, probes, or other equipment <br />replaced and list the manufacturer name and model for all replacement parts in Section E below. <br />Was liquid found inside any secondary containment systems designed as dry systems? <br />® Yes* El No <br />If yes, check the type(s) of liquid found and describe causes in Section E, below. ❑ Product ® Water <br />® Yes ❑ No* <br />Was monitoring system set-up reviewed to ensure proper settings? Attach set up reports, if applicable <br />® Yes ❑ No* <br />Is all monitoring equipment operational per manufacturers specifications? <br />* In Section E below, describe how and when these deficiencies were or will be corrected. <br />ILS <br />Other sensors from rage 1: <br />L3 North Sump sensor 794380 -208 -Pass <br />L4 Generator Room Trench sensor 794380 -420 -Pass <br />An Overfill Prevention Valve is installed in the drop tune. <br />Water found in L1 south sump ( 3 cups ) Marked water non haz and returned it to Tait`s shop. <br />Monitoring System Certification Page 2 of 4 12/07 <br />