My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2009-2012
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
T
>
TURNER
>
90
>
2300 - Underground Storage Tank Program
>
PR0231741
>
COMPLIANCE INFO_2009-2012
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/30/2020 10:41:19 AM
Creation date
6/23/2020 6:51:05 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2009-2012
RECORD_ID
PR0231741
PE
2361
FACILITY_ID
FA0003657
FACILITY_NAME
AT&T Corp. - UE231
STREET_NUMBER
90
Direction
W
STREET_NAME
TURNER
STREET_TYPE
Rd
City
Lodi
Zip
95242
CURRENT_STATUS
02
SITE_LOCATION
90 W Turner Rd
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231741_90 W TURNER_2009-2012.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
248
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Appendix VI <br />(Copies of Monitoring System Ceffication form and UST Monitoring Plot Plan available at http:ltwww.waterboards.ca.gov) <br />Monitoring System Certification <br />For Use By AN Jur isdidms Within tate Siete of Caflfornia <br />Authority Cited. Chapter 6.7, Health and Safety Code, Chapter 16, Division 3, 7"dte 23, Caliibmle Code of Regulations <br />This form nVA9 be used to document testing and servicing of morilto N equipment. A separate certification or report must be prepared for each <br />monitoring <br />m system <br />control <br />p a by the technician who performs the work. A copy of this form must be provided to the tank system ow nerloperator. The <br />copy of this form to the local agency regulating UST systems within 30 days of test date. <br />A. General Information <br />Facil!ty AT&T CoWabon <br />GEO PAR # UE231 <br />Address: J110 W. Turner Rd. <br />City: LodiZi : 95242 <br />Facility Contact Person: Connie Mitchell <br />Contact Phone No: 209-474-4022 <br />Make/Model of Monitoring System: Veeder Root TLS 350 <br />Service Date: 06/02/2010 <br />B. Inventory of Equipment Tested/Certified <br />Check the apprroprfate boxes to Indicate specific eciulprre nt Ins iced: <br />Tank ID:UE231U001 <br />Tank ID: <br />® in -Tank Gauging Probe Modaf:846390}109 <br />❑ In -Tanis Gauging Probe mel: <br />® Annular Space or Vault Sensor Moxdel:7943W420 <br />❑ Annular Space or Vault Sensor Model: <br />® Piping Sump / Trench Sensor(s) Model:794380-2013 <br />❑ Piping Sump / Trench Sensor(s) Madel: <br />❑ Fin Sump Sensor(s) Model: <br />❑ Fill Sump Sensor(s) Model: <br />❑ Mechanical Line Leak Detector Madel: <br />❑ Mechanical Line Leak Detector Model: <br />❑ Electronic Line Leak Defector Model: <br />❑ Electronic Line Leak Detector Model: <br />® Tank Overfill / High Level Sensor Model:790091-001 <br />❑ Tank Overfill / High Level Sensor Model: <br />® Other (Specify equipment type and modei in Section E on Page 2) <br />❑ Other (Specify equipment type and model In Section E on Page 2) <br />Tank ID: <br />Tank lD: <br />❑ 1n -Tank Gauging Probe Model: <br />❑ In -Tank Gauging Probe Model <br />❑ Annular Space or Vault Sensor Madel: <br />❑ Annular Space or Vault Sensor Model: <br />❑ Piping Sump / Trench Sensor(s) Model: <br />❑ Piping Sump / Trench Sensor(s) Model: <br />❑ Fill Sump Sensor(s) Model: <br />❑ Fill Sump Sensor(s) Model: <br />❑ Mechanical Line Leak Detector Model: <br />❑ Mechanical Line Leak Detector Model: <br />❑ Electronic Lite Leak Detector Model: <br />❑ Electronic Line Leak Detector Model: <br />❑ Tank Overfill / High Level Sensor Model: <br />❑ Tank Overfill / High Level Sensor Model: <br />❑ Other (Specify equipment type and model In Section E on Page 2) <br />❑ Other (Specify equipment type and model in Section E on Page 2) <br />Dispenser ID: <br />Dispenser ID: <br />❑ Dispenser Containment Sensor(s) Model: <br />❑ Dispenser Containment Se-,-or(s) Model: <br />❑ Shear Valve(s) <br />❑ Shear Vatve(s) <br />❑ Dispenser Containment Floats) and Chain(s) <br />❑ Dispenser Containment Float(s) and Chain(s) <br />Dispenser 10: <br />Dispenser ID: <br />❑ Dispenser Containment Sensor(s1 Model: <br />❑ Dispenser Containment Sensor(s) Model: <br />❑ Shear Va"s) <br />❑ Shear Valve(s) <br />❑ Dispenser Containment %ahs) and Chain(s) <br />❑ Dispenser Containment Fkoags) and Chain(s) <br />Dispenser ID: <br />Dispenser ID: <br />_ _ <br />❑ Dispenser Containment Sensor(s) Model: <br />❑ Dispenser Containment Sensor(s) Model: <br />❑ Shear Valves) <br />[❑ Shear Valve(s) <br />❑ Dispenser Containment Float(s) and Chain(s) <br />❑ Dispenser Containment Float(s) and Chain(s) <br />if the factilly contains more tanks or dispensers, copy this form. Include information for every tank and disj� at ft facility. <br />C. Certification- I certify that the equipment Idardifled In Oft document was I tted/servtcecl in accordance wait the <br />manufacturers' guidelines. Attached to this on Is Inforrnation (e g. rnan rens' checkiltit) necessary to verity <br />that this Information Is correct and a Plot Pian shovdng the layout of monitoring equipment. For any equipment capable of <br />generating such reports, I have also attached a copy of the report; (check all that apply): <br />®S tent set p root history report <br />Technician Name (Print): Christo <br />pher Derosier Si nature: <br />Certification No: B35665 I License No: 588098 <br />Testing Company Name: TAIT ENVIRONMENTAL SERVICES Phone No: 714 560-8222 <br />Testing Com an Address: 2131 South Duportt Drive Anaheim CA 92806 1 Date of Testing/Servicing: 06/02/2010 <br />Monitoring System Certification Page 1 of 4 12/07 <br />1 2/21/07 <br />
The URL can be used to link to this page
Your browser does not support the video tag.