COMPLIANCE INFO_1986-1990
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
V
>
VICTOR
>
880
>
2300 - Underground Storage Tank Program
>
PR0231746
>
COMPLIANCE INFO_1986-1990
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/3/2024 2:04:10 PM
Creation date
6/23/2020 6:51:24 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1986-1990
RECORD_ID
PR0231746
PE
2361
FACILITY_ID
FA0003862
FACILITY_NAME
Marks Fuel & Food, Inc.
STREET_NUMBER
880
Direction
E
STREET_NAME
VICTOR
STREET_TYPE
RD
City
LODI
Zip
95240
APN
049-050-32
CURRENT_STATUS
01
SITE_LOCATION
880 E VICTOR RD
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231746_880 E VICTOR_1986-1990.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
237
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
jokTER ENVIRONMENTAL SERVICED INC. <br />ij405 REDHILL AVENUE, SUITE is <br />TUSTIN, CALIFORNIA 92680 <br />t00-247-9014 800-247-2186 <br />CUSTOMER: Shell <br />ADDRESS: 880 Victor <br />Lodi, CA <br />® CT 1W FINAL TEST RESULTS <br />TEST DATE: 4-2-87 <br />Sip 2 8 9987 <br />ESQ` HEALTH <br />/S k�=I ATION NUMBER: 204-4416-0806 <br />F ER6JI <br />TEST RESULTS SUMMARY <br />Leak Lokator Results* <br />System Tank Size Water Level ALR <br />No. Product Gallons Dia/Matl Inches Inches GPH Conclusion Recommendations <br />1 Super 8000 95 0 161 Ullage Leaking <br />100 - .336 Leaking <br />95 - .121 Leaking <br />2 U/L 8000 95 0 185 - .016 Tight <br />3 R/L #1 5000 95 0 <br />178 Ullage Leaking <br />4 R/L #2 5000 950 95 Inconclusive <br />Uncover and Investigate. <br />See Investigative <br />Procedure. <br />Uncover and Investigate. <br />See Investigative <br />Procedure. <br />Other Informations Super ullaged 161" over 60 minutes. R/L ullaged 28" over 60 minutes. <br />PRODUCT LINES - HYDROSTATIC PRESSURE TEST RESULTS <br />System <br />No. Product <br />Type of Pumo <br />Remote <br />Pounds <br />Pounds <br />- .044 -21.237 -.336 Yes <br />- .031 -10.638 - 7.671 =.121 Yes <br />- .035 -11.657 - ! .058 -.016 No <br />over 60 minutes <br />Suction <br />ER2.Lied <br />Held <br />1 Super <br />Red Jacket <br />50 <br />47 <br />2 U/L <br />Red Jacket <br />50 <br />50 <br />3/4 R/L #1,2 <br />Red Jacket <br />50 <br />48 <br />Minutes Product Product Conclusion <br />HeldLoss CC's Loss GPH /Result <br />10 <br />10 <br />10 <br />Note: On suction systems, NEVER put more than 15 psi on any pump system. <br />DETAIL OF TEST RESULTS <br />Test Time Leak Rate <br />System Test. Level Clock Duration Temperature <br />No. Product No. Lin .)Start (Hr -Min) /DIV CC/MIN Del_ to -F <br />sation <br />CC <br />CCIMIN <br />1 Super 1 161 1-00 -23 inches in 60 minutes <br />2 100 1:25 0-33 -23 255 -36 <br />Tight <br />Tight <br />Tight <br />Absolute Check <br />Leak Rate Test <br />CC/MIN GPH t/N <br />3 <br />2 U/L 1 <br />3 R/L #1 1 <br />2 <br />95 <br />185 <br />178 <br />95 <br />2'45 0-32 <br />5:05 0-36 <br />11:05 1-00 <br />Inconclusive <br />• .337 <br />- 3.2-15.099 <br />b9 -18.310 <br />-2.040 -12.715 <br />Ullaged 28 inches <br />- .044 -21.237 -.336 Yes <br />- .031 -10.638 - 7.671 =.121 Yes <br />- .035 -11.657 - ! .058 -.016 No <br />over 60 minutes <br />4 R/L #2 1 <br />2 <br />178 <br />95 <br />11:05 1-00 <br />Inconclusive <br />*Level - Inches from Tani; Bottom to Test Level <br />ALR - Absolute Leak Rate (Measured Leak Rate - Temperature Compensation) i <br />Conclusion - NFPA 329 criterion of + 0.05 GPH is used to certify tightness <br />_ n Gallons Per Hour <br />CERTIFICATION <br />This is to certify that the above tank systems were tested, using the HUNTER EN <br />SERVICES, INC. LEAK LOKATOR according to all standard operatingprocedures. i <br />Those indica <br />as tight at full system meet the criterion established by the National <br />Fire Protection�ated <br />Association Pamphlet 329 for Precision Testing. <br />Tests Conducted By: Test Van No. LL -21 <br />Team Mana : Pat Wheeler. <br />• ng Pe - list- Evans <br />Certified By:M16 <br />chael L. Anesetti, Fiel Supervisor Date <br />