My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_1986-1990
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
V
>
VICTOR
>
880
>
2300 - Underground Storage Tank Program
>
PR0231746
>
COMPLIANCE INFO_1986-1990
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/3/2024 2:04:10 PM
Creation date
6/23/2020 6:51:24 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1986-1990
RECORD_ID
PR0231746
PE
2361
FACILITY_ID
FA0003862
FACILITY_NAME
Marks Fuel & Food, Inc.
STREET_NUMBER
880
Direction
E
STREET_NAME
VICTOR
STREET_TYPE
RD
City
LODI
Zip
95240
APN
049-050-32
CURRENT_STATUS
01
SITE_LOCATION
880 E VICTOR RD
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231746_880 E VICTOR_1986-1990.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
237
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
System, Model X76S <br />Power: 115 VAC, 60Hz <br />Power Consumption: 100 VA <br />Operating Temperature: 32 to 165°F (0 to 75°C) <br />Dimensions: 9x9.5x4.2 in. (22.86x24.13x10.67 cm) <br />Mounting: General purpose area; wall mount <br />FM Approved: File J.I. 2N4ALAX <br />Annunciator Module <br />Field Sensor: Dry contact <br />Field Sensor Voltage: 115 VAC (supplied by X76S) <br />Number of inputs: One per module <br /><'F-> Approved: File J.I. 2N4ALAX <br />Intrinsically Safe 'Field Sensor <br />Interface Module X53 <br />Number of Inputs: Two per module <br />Sensors Voltage: 24 VDC, current limited <br />Sensors: Dry contact <br />Output Interface to Alarm Module: Relay contact; <br />normally open/normally closed; selectable <br />Power Consumption: 750 mW per input <br />Supply Voltage: 24 VDC from IS power supply <br /><'Fm> Approved: File J.I. 2N4A1. AX <br />Power Supply IS. (In trinsically Safe) <br />Power Input: 115 VAC <br />Output Voltage: 24 VDC <br /><'-* Approved: File J.I.2N4ALAX <br />fto, 4 <br />Vapor Sensor, Model HV <br />Detection Method: Solid-state diffusion type <br />Detectable Gases: Hydrocarbons, gasoline, solvents, <br />carbon monoxide, methane, ammonia, sulfur dioxide, <br />hydrogen sulfide <br />Detectable Range: 0-100% LEL <br />Accuracy: :E5% <br />Response Time: Less than 15 sec. to 90% full scale <br />Sensitivity: 5 ppm <br />Sensor Life: 5 years minimum <br />Zero Drift: Less than 5% per year <br />Operating Temperature: —400 to 165°F (-400 to 75°C) <br />Electrical Classification: Class I, Division 1, Groups B, C <br />and D; hazardous atmosphere <br />Cable Length: 25 feet; 3 -conductor, number 20 AWG <br />shielded; max. length 3,000 feet <br />(D Approved: File E100826 <br />Operating Temperature: 0 to 225°F (-18 to 107°C) <br />Pressure: 50 psi maximum <br />Leads: 22 AWG <br />(io Approved: File E86797 <br />Tank Leak Sensor, Model LS -7 For fiberglass tank <br />Housing Material: ABS <br />Mounting: Y211 NPT with -A," THD and lock nut <br />Pressure: 150 psig at 70°F (210C) maximum <br />Liquid SpG: .70 minimum <br />Switch: <br />Type: Single pole, single throw N.C. <br />Rating: 10 VA, 110 to 240 VAC <br />Leads. 22 AWG <br />Approved: File E86797 <br />Feservoir T�pe T�tnk Leak Sensor, Model LS -1* <br />Reservoir: <br />volume: Two gallons (7.57 liters) <br />Dimensions (hekhtxjWd?hx depth): <br />13xllxll inches (33.02x27.94x27.94 cm) <br />Matendh Polyethylene plastic <br />Switch: <br />Tjpe.. Single pole, single throw <br />Rating- 10 VA, 110 to 240 VAC <br />Stem and, oat material: Polysulfone <br />Operating Temperature: 0 to 225 OF <br />(-18 to 1076C) <br />Pressure.- 50 psi maximum <br />Leadsy � AWG <br />TApproved: File E86797 <br />ordering infonnation <br />The Ronan Model X76S Leak Detector Monitor System <br />can be configured to meet the different local and state <br />codes for underground storage by proper selection of <br />sensors and monitor modules. For example, a particular <br />local code and/or type of facility may require leak detection <br />of a tank annulus. The monitor system would consist of the <br />following items: <br />Model X76S-( <br />1' No. of alarm inputs (I thru 4) max -4 <br />Accessories <br />Qty. Type <br />— LS -3 (Vertical liquid level sensing probe) <br />— LS -7 (Horizontal liquid level sensing probe) <br />LS -10 (Reservoir liquid level system) <br />— HV Vapor Sensor (Specify product <br />being monitored) <br />Tank Leak Sensor, Model LS -3 <br />RONAN ENGINEERING <br />LTD. U.K. <br />Housing: 304 stainless steel <br />warranty: Ronan warrants equipment of its own manufacture to be <br />free from defects in material and workmanship under normal conditions <br />Switch: <br />of use and service, and will repair or replace any component found to be <br />Type.. Single pole, single throw N.C. <br />defective, on its return, transportation charges prepaid, within one year <br />Ratir?g- 10 VA, 110 to 240 VAC <br />of its original purchase. This warranty carries no liability, either <br />expressed or implied, beyond our obligation to replace the unit which <br />Stem and float material: Fuel -proof polysulfone <br />carries the warranty. <br />RONAN ENGINEERING <br />RONAIM COMPANY <br />RONAN ENGINEERING <br />LTD. U.K. <br />RONAN ENGINEERING <br />LIMITED <br />RONAN ENGINEERING <br />(RUST.) PTY. LTD. <br />P.O. Box 1275 <br />1 Tilley Road <br />32 Bermondsey Road <br />Unit 10, 8 Leighton Place <br />21200 Oxnard Street <br />Crowther District 3 <br />Toronto, Ontario <br />Hornsby, N.S.W. 2077 <br />Woodland Hills, <br />California 91367 U.S.A. <br />Washington, Tyne and Wear <br />United Kingdom. NE38-OEA <br />Canada M4BIZ5 <br />(416) 752-0310 ® Telex 63662 <br />Australia <br />(02) 477-7344 *Telex 73467 <br />(818) 883-5211 a Telex 698-490 <br />(091) 416-1689 0 Telex 537-746 <br />FAX (416) 752-8072 <br />FAX (02) 477-6151 <br />FAX (818) 992-6435 <br />FAX (091) 416-5856 <br />A286 <br />Printed in U.S.A <br />