My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_1986-1990
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
V
>
VICTOR
>
880
>
2300 - Underground Storage Tank Program
>
PR0231746
>
COMPLIANCE INFO_1986-1990
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/3/2024 2:04:10 PM
Creation date
6/23/2020 6:51:24 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1986-1990
RECORD_ID
PR0231746
PE
2361
FACILITY_ID
FA0003862
FACILITY_NAME
Marks Fuel & Food, Inc.
STREET_NUMBER
880
Direction
E
STREET_NAME
VICTOR
STREET_TYPE
RD
City
LODI
Zip
95240
APN
049-050-32
CURRENT_STATUS
01
SITE_LOCATION
880 E VICTOR RD
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231746_880 E VICTOR_1986-1990.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
237
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
, u <br /> STATE OF CALIFORNI WATER RESOURCES coNTRARD SSE °* �faA <br /> '• NDERGROUND STORAGE TANK PROGRAM <br /> 40 <br /> FORMV:. U �o <br /> TANK TANK PERMIT APPLICATION INFORMATION <br /> COMPLETE A SEPARATE FORM WITH THE FOLLOWING INFORMATION FOR EACH TANK. <br /> MARK ONLY ❑ 1 NEW PERMIT ❑ 3 RENEWAL PERMIT 5 CHANGE OF INFORMATION n�BTANK <br /> MANENTLY CLOSED TANK <br /> ONE ITEM ❑2 INTERIM PERMIT F-1 4 AMENDED PERMIT ❑ 6 TEMPORARY TANK CLOSURE �/ REMOVED eX <br /> W <br /> FACILITY/SITE NAME WHERE TANK IS INSTALLED CtFV pd FARM TANK-YES❑ NO <br /> I. TANK DESCRIPTION COMPLETE ALL ITEMS-IF UNKNOWN-SO SPECIFY 00 <br /> A. OWNERS TANK ID# B. MANUFACTURED BY: -4 <br /> C. YEAR INSTALLED D. TANK CAPACITY IN GALLONS: Q <br /> II. TANK CONTENTS IF(A.1),IS MARKED,COMPLETE ITEM C.IF(A.1),IS NOT MARKED,COMPLETE ITEM D. <br /> A. ❑ 1 MOTOR VEHICLE FUEL ❑ 2 PETROLEUM B. C. 1 UNLEADED 2 LEADED 3 DIESEL <br /> 3 CHEMICAL PRODUCT4 OIL ❑ 1 PRODUCT ❑ 4 GASAHOL 5 JET FUEL 6 AVIATION GAS <br /> ❑ 5 HAZARDOUS ❑ 80 EMPTY ❑ 95 UNKNOWN EA,-*ASTE ❑ 7 METHANOL [2119 OTHER(DESCRIBE IN ITEM D,BELOW) <br /> D. IF NOT MOTOR VEHICLE FUEL,ENTER NAME OF <br /> HAZARDOUS SUBSTANCE STORED&C.A.S.# t C.A.S.#: �1 <br /> III. TANK CONSTRUCTION MARK ONE ITEM ONLY IN BOX A,B,C,&D <br /> A.TYPE OF ❑ 1 DOUBLE WALLED ❑3 SINGLE WALLED WITH EXTERIOR LINER ❑ 95 UNKNOWN <br /> SYSTEM U`SINGLE WALLED ❑4 SECONDARY CONTAINMENT ❑ 99 OTHER <br /> 1 STEEL/IRON 2 STAINLESS STEEL 3 FIBERGLASS ❑ 4 STEEL CLAD W/FIBERGLASS REINFORCED PLASTIC <br /> B.TANK IF--' 5 CONCRETE F-] 6 POLYVINYLCHLORIDE F-] 7 ALUMINUM F-]8 100%METHANOL COMPATIBLE FRP <br /> MATERIAL <br /> ❑ 9 BRONZE ❑ 10 GALVANIZED STEEL ❑ 95 UNKNOWN ❑ 99 OTHER <br /> C. INTERIOR 1 RUBBER LINED 2 ALKYD LINING F-13 EPDXY LINING F-]4 PHENOLIC LINING <br /> LINING ❑ 5 GLASS LINING 6 UNLINED ❑ 95 UNKNOWN <br /> ❑ IS LINING MATERIAL COMPATIBLE WITH 100%METHANOL? ❑YES [:] NO �9 J <br /> OTHER A^4-- <br /> D.CORROSION ❑ 1 POLYETHLENE WRAP TAR OR ASPHALT F-13 VINYL WRAP ❑4 FIBERGLASS REINFORCED PLASTIC <br /> PROTECTION [:]5 CATHODIC PROTECTION K91 NONE ❑ 95 UNKNOWN ❑ 99 OTHER <br /> IV. PIPING INFORMATION CIRCLE A IF ABOVE GROUND, U IF UNDER ROUND,BOTH IF APPLICABLE <br /> A.SYSTEM TYPE A U 1 SUCTION A U 2 PRESSURE A 3 GRAVITY A U 91 NONE A U 95 UNKNOWN A U 99 OTHER <br /> B. CONSTRUCTION A U SINGLE WALLED A U 2 DOUBLE WALLED A U 3 LINED TRENCH A U 91 NONE A U 95 UNKNOWN A U 99 OTHER <br /> A U 1 STEEL/IRON A U 2 STAINLESS STEEL A U 3 POLYVINYL CHLORIDE(PVC) A U 4 FIBERGLASS PIPE A U 91 NONE <br /> C.MATERIAL A U 5 ALUMINUM A U 6 CONCRETE A U 7 STEEL CLAD W/FRP A U 8 100%METHANOL COMPATIBLE FRP <br /> Ag 9 GALVANIZED STEEL A U 95 UNKNOWN A U 99 OTHER <br /> V. LEAK DETECTION SYSTEM CIRCLE P FOR PRIMARY,OR S FOR SECONDARY,A PRIMARY LEAK DETECTION SYSTEM MUST BE CIRCLED. <br /> A P S 1 VISUAL CHECK P S 2 INVENTORY RECONCILIATION P S 3 VADOSE WELLS P S 4 ELECTRONIC MONITOR P S 5 GROUND WATER MONITORING WELLS <br /> D P S 6 PRECISION TESTING P S 7 PRESSURETESTING P S 1 NONE P S 95 UNKNOWN P S 99 OTHER <br /> VI. INFORMATION ON TANK PERMANENTLY CLOSED IN PLACE <br /> 1. ESTIMATED DATE LAST USED(MO/YR) 2. ESTIMATED UANTITY OF 3.WAST NK FILLED WITH <br /> SUBSTAN REMAINING IN INERT TERIAL? ❑YES ❑ NO <br /> GALLONS <br /> THIS FOR HAS BEEN COMPLETED UNDER PENALTY OF PERJURY,AND TO THE BEST OF MY KNOWL DGE,IS TRUE AND CORRECT. <br /> APPLICANT'S NAME(PRINTED&SIGNATURE) DATE <br /> LOCAL AGENCY USE ONLY <br /> COUNTY# JURISDICTION# AGENCY# FACILITY ID# TANK ID# <br /> Eo lc,,7 lo I <br /> IPERMIT <br /> ENT LOCAL AGENCY FACILITY ID# APPROVED BY 1/"AME PHONE#WITH AREA CODE <br /> /J Z� <br /> NUMBER PER IT APP V L DATE PERMIT EXPIRATION DATE <br /> 9(110 <br /> K# PERMIT AMOUNT SDRC AR E A FEE CODE RECEIPT# BY: <br /> F RM 8 6-29-88 THIS FORM MUST BE AC MPANI A FACILITY/SITE APPLICATION FORMA UNLESS RENT FORMA' HAS BEEN FILED <br /> o ( ) CO , <br /> DATA PROCESSING COPY <br />
The URL can be used to link to this page
Your browser does not support the video tag.