Laserfiche WebLink
RLIM me -.1 <br />a a 0. : .0. <br />. • •:32 <br />WOMI-1,1111,611"M A <br />TEST DATE: March 23, 1994 <br />CLIENT: SHELL OIL COMPANY <br />WORK ORDER NUMBER: 962336 <br />SITE: SHELL 204-4416-0806 <br />Tank ID: <br />2 <br />Bottom to top fill in inches: <br />153.0 <br />Product: <br />PLUS <br />Bottom to grade fill in inches: <br />150.0 <br />Capacity in gallons: <br />5,225 <br />Fill pipe length in inches: <br />55.0 <br />Diameter in inches: <br />95.00 <br />Fill pipe diameter in inches: <br />4.0 <br />Length in inches: <br />173 <br />Stage I vapor recovery: <br />DUAL <br />Material: <br />STEEL <br />Stage II vapor recovery: <br />ASSIST <br />Tank: <br />YES <br />Resiliency cc: 120 <br />Water table depth in inches: <br />Manifolded Vent: <br />No <br />Determined by (method): <br />NO WELL <br />V/H: NO <br />;COMMENTS, <br />THIS TANK IS LISTED AS #2 ON THE MONITOR SYSTEM. <br />Test method: <br />VPLT <br />New/passed Failed/replaced <br />Psi at tank bottom: <br />1.80 <br />detector detector <br />Fuel level in inches: <br />66.74 <br />Test method: PTA <br />UFT/OFT: <br />UE'T <br />Make: RED JACKET <br />Fuel volume in gallons: <br />3.922 <br />Model: D.L.D. <br />Water level in inches: <br />0.00 <br />S/N: 111913732 <br />Test time: <br />21:02-23:32 <br />Open time in sec: 5.00 <br />Number of thermisters: <br />5 <br />Holding psi: 13 <br />Specific gravity: <br />0.746 <br />Resiliency cc: 120 <br />Water table depth in inches: <br />Test leak rate ml/h: 252.0 <br />Determined by (method): <br />NO WELL <br />Metering psi: 10 <br />Leak rate in gph: <br />-0.018 <br />Calib. leak in gph: 3.00 <br />RESULT. <br />PASS <br />RESULT. PASS <br />COMMENTS COMMENTS <br />Test method: <br />UTS-4 SYSTEM <br />Test time: <br />23:45-00:25 <br />Ullage volume: <br />1,302 <br />Ullage pressure: <br />2.20 <br />RESULT: <br />PASS <br />DATA FOR UTS-4T ONLY: <br />Time of test 1: <br />Temperature: <br />Flow rate: <br />Time of test 2: <br />Temperature: <br />Flow rate: <br />Time of test 3: <br />Temperature: <br />Flow rate: <br />23:55-00:05 <br />73.20 <br />0.200-0.200 <br />00:05-00:15 <br />73.10 <br />0.200-0.150 <br />00:15-00:25 <br />73.00 <br />0.200-0.150 <br />—COMMENTS <br />Material: STEEL <br />Diameter (in): <br />Length (in): <br />Test psi: <br />Bleedback cc: <br />Test start time <br />Test 1: start time: <br />finish psi: <br />vol change cc: <br />Test 2: start time: <br />finish psi: <br />vol change cc: <br />Test 3: start time: <br />finish psi: <br />vol change cc: <br />Final gph: <br />RESULT: <br />2.0 <br />40.0 <br />5o <br />0 <br />30 <br />21:30 <br />48 <br />10 <br />21:40 <br />48 <br />5 <br />21:50 <br />49 <br />5 <br />0.011 <br />PASS <br />Test type: PTK-88 <br />Pump type: PRESSURE Pump make: RED JACKET <br />