My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_1991-1994
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
V
>
VICTOR
>
880
>
2300 - Underground Storage Tank Program
>
PR0231746
>
COMPLIANCE INFO_1991-1994
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/3/2024 2:06:49 PM
Creation date
6/23/2020 6:51:27 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1991-1994
RECORD_ID
PR0231746
PE
2361
FACILITY_ID
FA0003862
FACILITY_NAME
Marks Fuel & Food, Inc.
STREET_NUMBER
880
Direction
E
STREET_NAME
VICTOR
STREET_TYPE
RD
City
LODI
Zip
95240
APN
049-050-32
CURRENT_STATUS
01
SITE_LOCATION
880 E VICTOR RD
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231746_880 E VICTOR_1991-1994.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
452
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
STATE OF CAUFORMA AP <br />600�e's C° <br />STATE WATER RESOURCES CONTROL BOARD°o <br />UNDERGROUND STORAGE TANK PERMIT APPLICATION - FORM B <br />COMPLETE A SEPARATE FORM FOR EACH TANK SYSTEM <br />MARK ONLY ELK1' NEW PERMIT ❑ <br />3 RENEWAL PERMIT <br />❑ <br />5 CHANGE OF INFORMATION <br />❑ 7 PERMANENTLY CLOSED ONSITE <br />ONE ITEM ❑ 2 INTERIM PERMIT ❑ <br />4 AMENDED PERMIT <br />❑ <br />6 TEMPORARY TANK CLOSURE <br />❑ 8 TANK REMOVED <br />DBA OR FACILITY NAME WHERE TANK IS INSTALLED:lv4j1;L.L.--TI <br />❑ 3 FIBERGLASS <br />❑ 4 STEEL CLAD W/ FIBERGLASS REINFORCED PLASTIC <br />QVA <br />❑ 5 CONCRETE <br />I. TANK DESCRIPTION COMPLETE ALL ITEMS - SPECIFY IF UNKNOWN <br />A. OWNER'S TANK I. D. A <br />B. <br />PRODUCT <br />B. MANUFACTURED BY: �' ��� /�� ` I �J <br />�1 <br />C. DATE INSTALLED (MO/DAY/YEAR) <br />6-91 <br />amu <br />D. TANK CAPACITY IN GALLONS: 12 <br />II. TANK CONTENTS IFA -1 IS MARKED. COMPLETE ITEM C. <br />A. 1 MOTOR VEHICLE FUEL ❑ 4 OIL <br />B. <br />PRODUCT <br />C. ❑ la REGULAR3 DIESEL ❑ 6 AVIATION GAS <br />1bP MIUM ❑ 4 GASAHOL <br />7 <br />2 PETROLEUM ❑ 80 EMPTY <br />SYSTEM <br />❑ ❑ METHANOL <br />NLEADED ❑ 5 JET FUEL <br />❑ 3 CHEMICAL PRODUCT ❑ 95 UNKNOWN <br />O 2 WASTE <br />2 LEADED ❑ 99 OTHER (DESCRIBE IN ITEM D. BELOW) <br />D. IF (A.1) IS NOT MARKED, ENTER NAME OF SUBSTANCE STORED C. A. S. #: <br />III_ TANK CONSTRUCTION MARK ONE ITEM ONLY IN BOXES A_ B. AND C. AND ALL THAT APPLIES IN BOX D <br />A. TYPE OF <br />7�171 DOUBLE WALL <br />F—] 3 SINGLE WALL WITH EXTERIOR LINER <br />❑ 95 UNKNOWN <br />SYSTEM <br />❑ 2 SINGLE WALL <br />❑ 4 SECONDARY CONTAINMENT (VAULTED TANK) <br />❑ 99 OTHER <br />1 SINGLE WALL <br />F-11 BARE STEEL <br />F-]2 STAINLESS STEEL <br />❑ 3 FIBERGLASS <br />❑ 4 STEEL CLAD W/ FIBERGLASS REINFORCED PLASTIC <br />B. TANK <br />MATERIAL <br />❑ 5 CONCRETE <br />❑ 6 POLYVINYL CHLORIDE <br />❑ 7 ALUMINUM <br />8 100% METHANOL COMPATIBLE W/FRP <br />(Primary Tank) <br />❑ 9 BRONZE <br />❑ 10 GALVANIZED STEEL <br />❑ 95 UNKNOWN <br />❑ 99 OTHER <br />❑ 1 RUBBER LINED <br />❑D LINING <br />❑ 3 EPDXY LINING <br />❑ 4 PHENOLIC LINING <br />C. INTERIOR <br />F75 GLASS LINING <br />UNLINED <br />❑ 95 UNKNOWN <br />❑ 99 OTHER <br />LINING <br />A U 95 UNKNOWN A U 99 OTHER <br />D. LEAK DETECTION <br />AUTOMATIC LINE LEAK DETECTOR 2 LINE TIGHTNESS TESTING ❑ 3 INTERSTITIAL MONITORING ❑ 99 OTHER <br />IS LINING MATERIAL COMPATIBLE WITH 1009/6 METHANOL? <br />YES_ NO <br />D. CORROSION <br />❑ 1 POLYETHYLENE WRAP <br />❑ 2 COATING <br />❑ 3 VINYL WRAP4 <br />FIBERGLASS REINFORCED PLASTIC <br />PROTECTION <br />❑ 5 CATHODIC PROTECTION ❑ 91 NONE <br />❑ 95 UNKNOWN <br />❑ 99 OTHER <br />IV. PIPING INFORMATION CIRCLE A IF ABOVE GROUND OR U IF UNDERGROUND. BOTH IF APPLICABLE <br />A. SYSTEM TYPE <br />A U <br />1 SUCTION <br />A 0 2 PRESSURE <br />A U <br />3 GRAVITY A U 99 OTHER <br />B. CONSTRUCTION <br />A U <br />1 SINGLE WALL <br />A W 2 DOUBLE WALL <br />A U <br />3 LINED TRENCH A U 95 UNKNOWN A U 99 OTHER <br />A U <br />1 BARE STEEL <br />A U 2 STAINLESS STEEL <br />A U <br />3 POLYVINYL CHLORIDE (PVC)A W4 FIBERGLASS PIPE <br />C. MATERIAL AND <br />CORROSION <br />A U <br />5 ALUMINUM <br />A U 6 CONCRETE <br />A U <br />7 STEEL W/COATING A U 6 100% METHANOL COMPATIBLE W/FRP <br />PROTECTION <br />A U <br />9 GALVANIZED STEEL <br />A U 10 CATHODIC PROTECTION <br />A U 95 UNKNOWN A U 99 OTHER <br />D. LEAK DETECTION <br />AUTOMATIC LINE LEAK DETECTOR 2 LINE TIGHTNESS TESTING ❑ 3 INTERSTITIAL MONITORING ❑ 99 OTHER <br />V. TANK LEAK DETECTION <br />1 ISUAL CHECK 2 INVENTORY RECONCILIATION3 VAPOR MONITORING 52"4 AUTOMATIC TANK GAUGING ❑ 5 GROUND WATER MONITORING <br />ESO6 TANK TESTING ❑ 7 INTERSTITIAL MONITORING ❑ 91 NONE ❑ 95 UNKNOWN ❑ 99 OTHER <br />VI. TANK CLOSURE INFORMATION <br />1. ESTIMATED DATE LAST USED (MO/DAY/YR) 2. ESTIMATED QUANTITY OF 3. WAS TANK FILLED WITH YES ❑ NO <br />SUBSTANCE REMAINING GALLONS INERT MATERIAL? <br />THIS FORM HAS BEEN COMPLETED UNDER PENALTY OF PERJURY, AND TO THE BEST OF MY KNOWLEDGE, IS TRUE AND CORRECT <br />APPLICANTS NAME �2&4-//^^ DATE <br />(PRINTED&SIGNATURE)�1�➢�' Ci/°� .1. ai (Ai_.a.. � i � -,y_,� .J� i�,� <br />LOCAL AGENCY USE ONLY THE <br />- THE STATE I.D. NUMBERS COMPOSED OFT FOUIR-SN1I iMRr-RS BELOW w�c�+ ` �� <br />COUNTY # JURISDICTION # FACILITY # TANK # <br />STATE I.D.# m <br />PERMIT NUMBER PERMIT APPROVED BY/DATE PERMIT EXPIRATION DATE <br />FORMS (9.90) THIS FORM MUST BE ACCOMPANIED BY A PERMIT APPLICATION • FORM A, UNLESS A CURRENT FORM A HAS BEEN FILED. <br />FOR00348•R4 <br />
The URL can be used to link to this page
Your browser does not support the video tag.