Laserfiche WebLink
• •}. • {� (...�'°¢� • !•.."t III,' R'%It 1• t <br /> in the current database. In fact, a new leak test is <br /> performed every time new data from an idle period is <br /> added. <br /> Since the database is constantly being updated, leak <br /> test results are aiways current—not results from a static <br /> leak test that may be days or even weeKs old. <br /> Leak tests are performed using the best data from up to <br /> the previous 28 days, and test results are continuously <br /> e e updated as new data are gathered. Test results are <br /> provided automatically every 24 hours. Press a key at <br /> any time to access up-to-the-minute leak test results. <br /> ► Uninterrupted business for 24-hour stations or Greater accuracy, quicker response times <br /> around-the-clock fueling operations. CSLD's algorithm sorts through all available information <br /> and uses only the highest quality data to perform its leak <br /> P- Automatic, continuous operation—no need tests. Since invalid data are thrown out and only the best <br /> to schedule test times. data are used, leak test results are more accurate.The <br /> chance of false alarms is greatly reduced. <br /> o- Third-party tested—exceeds U.S. c P.A. <br /> standards! Because leak test data are collected continuously and <br /> updated frequently,the response time to detect leaks is <br /> ► Meets Federal, state and local compliance shorter than that of scheduled static leak tests. <br /> requirements for monthly monitoring. <br /> Certified Solution for Manifolded Tank <br /> ► Certified for manifolded tanks. CSLD is the one system certified for manifolded tank <br /> ► Up-to-the-minute leak test results available applications. Owners of sites with manifoided tanks can <br /> 24 hours a day. alperform continuous in-tank leak tests to meet U.S. <br /> E.P.A., performance standards for monthly monitoring <br /> ► Automatic leak test report every 24 hours. without the need to shut down. Static leak tests are <br /> accommodated without the need to break the siphon <br /> ► Qualified for tanks up to 30.000 gallons. between manifolded tanks. <br /> ► More accurate test results... fewer false alarms. CSLD accurately monitors manifoided tank sets with up <br /> ► Simple upgrades available for TLS-'SO and to three tanks per set, totaling a capacity of up to 30.000 <br /> 350R systems already in the field. gallons per set. During system setup and operation, the <br /> manifolded tank sets are recognized as one tank. <br /> Automatic, continuous leak detection Third-Party Certified <br /> CSLD is advanced tank testing technology. Third-party testing confirmed that CSLD meets Federal, <br /> Veeder-Root Consoles with CSLD continuously monitors state and local compliance requirements for monthly <br /> fuel height and temperature information to detect idle monitoring.Test results showed a 99°o probability of <br /> times in the tank. During each idle period, data is detection and less than a 0.'°o chance of false alarm! <br /> collected and combined with information from other idle That far exceeds the U.S. E.P.A. performance standards <br /> periods to form a highly accurate leak detection data- 9S% probability of detection and 5°o probability of <br /> fa <br /> base. Sophisticated statistical analysis techniques in false alarm. <br /> CSLD constantly evaluate all new and all existing Call us for a copy of the test results. <br /> information in the database to discard invalid data and <br /> perform leak tests based on only high-quality information (continued) <br />