My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_1995-1999
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
V
>
VICTOR
>
880
>
2300 - Underground Storage Tank Program
>
PR0231746
>
COMPLIANCE INFO_1995-1999
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/25/2023 3:55:50 PM
Creation date
6/23/2020 6:51:35 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1995-1999
RECORD_ID
PR0231746
PE
2361
FACILITY_ID
FA0003862
FACILITY_NAME
Marks Fuel & Food, Inc.
STREET_NUMBER
880
Direction
E
STREET_NAME
VICTOR
STREET_TYPE
RD
City
LODI
Zip
95240
APN
049-050-32
CURRENT_STATUS
01
SITE_LOCATION
880 E VICTOR RD
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231746_880 E VICTOR_1995-1999.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
297
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
r <br /> UST SYSTEM PRINTSEt INFORMATION <br /> 1, y Four complete sets of plans (To include specification sheets and/or equipment brochures If not on file). <br /> 2, v_ Plans drawn to scale in non-erasable print. <br /> V Plot plan to show location and number of tanks. <br /> Tank cross-sectional diagram included on prints submitted. <br /> 5, Detail of tank, piping system, excavation and cover. <br /> Tank(s) and piping approved by a nationally recognized independent testing organization. [Title 23, Subchapter 16, <br /> Article 3, Sec. 2631 (r) & 26351 <br /> Verification of product compatibility with the tank(s), piping, monitoring <br /> device(s), epoxy or silicone glues, etc. [Section 2635 (b) (2)) <br /> g, Manufacturers written installation instructions for tank(s), piping, monitoring devices, etc. [Section 2635 tbD (S)I <br /> 9, Tightness Test (NEPA 30) Is required on both primary (io) and secondary (20) containment system before covering. <br /> [Section 2635 (b) (6) & (7)) <br /> Double welted tanks using pressure or vacuum testing to monitor the annular space. [Section 2635 (b) (7)) <br /> ✓' NFPA 329 "Precision test" required upon completion of installation with tank in operating condition. Test results to <br /> be submitted directly to PNS/ENO from the testing company or owner of facility. [Health & Safety Code, Division 20, <br /> Chapter 6.7, Section 25291 (g)l <br /> 12. TANK COMPOSITION <br /> TANK 0 0 I g � 0 0 0 <br /> CAPACITY ' ; i)) L1. Ca L- Cid <br /> MANUFACTURER C 1, 6 C (" <br /> COMPOSITION Et(i I � ��> rL12c ` <br /> MODEL I C <br /> PRODUCT C,r I i C ClC I <br /> CORROSION PROTECTION <br /> U.L. LISTED <br /> COMPATIBILITY WITH 100% <br /> METHANOL l "� <br /> 13. TANK(s) TO NE INSTALLED <br /> A. Steel-clad with fiberglass reinforced plastic. <br /> Holiday test required immediately before "setting" tank(s) (35,000 - 40,000 volts). [Section 2635 (b) (4)1 <br /> C. Fiberglass [Sections 2635 (3) and 2631 (p)) <br /> (1) Striker plate dimensions and materials. <br /> _ (2) Striker plate under alt accessible openings. <br /> (3) Installation instructions require an air test and soap bubble test prior to installation. <br /> [,!/A D. Non-clad steel tank [Section 2635 (b)l <br /> (1) Cathodic protection provided for entire tank, piping and components (ruts, bolts, washers, <br /> etc.). <br /> (2) Approved by a corrosion engineer or N.A.C.E. technician. <br /> (3) Document stating inspection method and frequency(minimum semi-annual inspection requirement). <br /> 4 <br />
The URL can be used to link to this page
Your browser does not support the video tag.