My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2004-2009
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
V
>
VICTOR
>
880
>
2300 - Underground Storage Tank Program
>
PR0231746
>
COMPLIANCE INFO_2004-2009
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/3/2024 2:30:52 PM
Creation date
6/23/2020 6:51:37 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2004-2009
RECORD_ID
PR0231746
PE
2361
FACILITY_ID
FA0003862
FACILITY_NAME
Marks Fuel & Food, Inc.
STREET_NUMBER
880
Direction
E
STREET_NAME
VICTOR
STREET_TYPE
RD
City
LODI
Zip
95240
APN
049-050-32
CURRENT_STATUS
01
SITE_LOCATION
880 E VICTOR RD
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
KBlackwell
Supplemental fields
FilePath
\MIGRATIONS\V\VICTOR\880\PR0231746\FINAL JUDGMENT 11-06-09.PDF
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
563
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
bo <br /> UNIFIED PROGRAM CONSOLIDATED FORM 7-4 l ) TANKS <br /> UNDERGROUND STORAGE TANKS-TANK PAGE 1 <br /> (tiro pages per tank) I <br /> Page of <br /> TYPE OF ACTION ❑1.NEW SITE PERMIT ❑ 4. AMENDED PERMIT All, <br /> CHANGE OF INFORMATION) ❑ 8. TEMPORARY SITE CLOSURE I <br /> (Check one item only) A 1_ ❑ 7. PERMANENTLY CLOSED ON SITE <br /> ❑3.RENEWAL PERMIT (Spey mason•for local use only) (Specdy change-for ocal use only) ❑ 8. TANK REMOVED 430 O <br /> 1 <br /> BUSINESS NAME(Same as FACILITY NAME or DBA-Doing Business As) FACILITY too <br /> LOCATION WITHIN SITE(Optionaq 431 <br /> fes\ � C <br /> LEtc <br /> 1.TANK DESCRIPTION <br /> TANK ID 0 TANK M NUFACTURER ECOMPARTMENTALIZED TANK 11 Yes No <br /> �� �� � 45 � � ��� � It'Yea',complete one page for each com rtmant. <br /> DATE INSTALLED(YEAR/M0I TANK CAPACITY IN GALLONS NUMBER OF COMPARTMENTS <br /> ADDITIONAL DESCRIPTION(Forlocal use only) <br /> 11.TANK CONTENTS <br /> TANK USE 432 PETROLEUM TYPE C1 5. JET FUEL <br /> 1. MOTOR VEHICLE FUEL ta REGULAR UNLEADED ❑ 2. LEADED <br /> marked,complete Petroleum Type) ❑1b. PREMIUM UNLEADED ❑ 3. DIESEL ❑ S. AVIATION FUEL <br /> ❑ <br /> ❑ 2. NON-FUEL PETROLEUM El 1c. MIDGRADE UNLEADED ❑ 4. GASOHOL 99. OTHER <br /> ❑ 3. CHEMICAL PRODUCT COMMON NAME(from Hazardous Materials Inventory page) CAS 0(from Hazardous Materials Inventory page) <br /> ❑ 4. HAZARDOUS WASTE(includes <br /> Used Oil) <br /> 95 UNKNOWN - III.TANK CONSTRUCTION <br /> TYPE OF TANK ❑ 1. SINGLE WALL ❑ 3. SINGLE WALL WITH ❑ 5. SINGLE WALL WITH INTERNAL BLADDER SYSTEM <br /> EXTERIOR MEMBRANE LINER ❑95. UNKNOWN <br /> (Check one item only) t� DOUBLE WAIL '❑ 4. SINGLE WALL IN A VAULT <br /> ❑99. OTHER <br /> TANK MATERIAL•primary tank ❑ 1. BARE STEEL El3. FIBERGLASS I PLASTIC C35. CONCRETE ❑95. UNKNOWN <br /> (Check one item only) ❑ 2. STAINLESS STEEL ❑4. STEEL CLAD W/FIBERGLASS ❑ 8. FRP COMPATIBLE W/1001,1e METHANOL ❑99. OTHER <br /> REINFORCED PLASTIC(FRP) <br /> TANK MATERIAL-secondary tank ❑ 1 BARE STEEL ❑ 3 FIBERGLASS I PLASTIC ❑ 8. FRP COMPATIBLE W1100%METHANOL ❑95. UNKNOWN <br /> (Check one item only) ❑ 2. STAINLESS STEEL ❑ 4. STEEL CUD W/FIBERGLASS ❑ 9. FRP NON-CORROOIBLE JACKET ❑99. OTHER <br /> REINFORCED PLASTIC(FRP) ❑10. COATED STEEL <br /> ❑ 5. CONCRETE <br /> DATE INSTALLED <br /> TANK INTERIOR LINING ❑ 1• RUBBER LINED ❑ 3. EPDXY LINING ❑ 5. GLASS LINING ❑95. UNKNOWN433 <br /> OR COATING <br /> ❑ 2. ALKYD LINING ❑ 4. PHENOLIC LINING ❑ 8. UNLINED 99. OTHER (For local use on!) <br /> (Check one item onl) DATE INSTALLED <br /> OTHER CORROSION ❑ 1. MANUFACTURED CATHODIC ❑ 3. FIBERGLASS REINFORCED PLASTIC ❑95. UNKNOWN 434 <br /> PROTECTION IF APPLICABLE PROTECTION ❑99. OTHER <br /> ❑ 4. IMPRESSED CURRENT (For local use only) <br /> (Check one item only) ❑ 2. SACRIFICIAL ANODE <br /> SPILL AND OVERFILL YEAR INSTALLED TYPE(Forlocal use only) OVERFILL PROTECTION EQUIPMENT:YEAR INSTALLED <br /> (Check all that apply) ❑ 1. SPILL CONTAINMENT ❑ 1. ALARM ❑ 3. FILL TUBE SHUT OFF VALVE <br /> DROP TUBE �© ❑ 2. BALL FLOAT ❑ 4. EXEMPT <br /> ❑ 3. STRIKER PLATE <br /> IV.'TANK LEAK DETECTION <br /> IF DOUBLE WALL TANK OR TANK WITH BLADDER(Check one item onty): <br /> IF SINGLE WALL TANK(Check all that a ): <br /> ❑ 1, VISUAL(EXPOSED PORTION ONLY) ❑ 5. MANUAL TANK GAUGING(MTG) ❑ 1. VISUAL(SINGLE WALL IN VAULT ONLY) . <br /> ❑ 2. AUTOMATIC TANK GAUGING(ATG) ❑ S. VADOSE ZONE 2. CONTINUOUS INTERSTITIAL MONITORING <br /> ❑ 3. MANUAL MONITORING <br /> ❑ 3. CONTINUOUS ATG - ❑ 7. GROUNDWATER <br /> ❑ 4. STATISTICAL INVENTORY RECONCILIATION(SIR)• ❑ 8. TANK TESTING <br /> BIENNIAL TANK TESTING 099. OTHER <br /> V.TANK CLOSURE INFORMATION/PERMANENT CLOSURE IN PLACE <br /> ESTIMATED DATE LAST USED(YR/MO/DAY) ESTIMATED QUANTITY OF SUBSTANCE REMAINING 435 TANK FILLED WITH INERT MATERIAL? <br /> gallons ❑Yea ❑No <br /> Formerly SWRCS Form B <br /> CUPAFORM(4/99) <br />
The URL can be used to link to this page
Your browser does not support the video tag.