Laserfiche WebLink
ONITO NG SYSTEM CETIFIC N <br /> Fo By All Jurisdictions Within the State of California <br /> Authority Cited:Chapter 6.7,Health and Safety Code;Chapter 16,Division 3 Title 23,California Code of Regulations <br /> This form must be used to document testing and servicing of monitoring equipment. If more than one monitoring system control panel is installed at the facility,a separate <br /> certification or report must be prepared for each monitoring system control panel by the technician who performs the work. A copy of this form must be provided to the tank <br /> system owner/operator. The owner/operator must submit a copy of this form to the local agency regulating UST systems within 30 days of test date. <br /> A.General Information <br /> Facility Name: CHEVRON#96171 City: STOCKTON CA Zip:95204 <br /> Site Address: 6633 PACIFIC AVE Contact Phone No: 477-4115 <br /> BENJAMIN HOLT DR. Date of Testing/Service: 02/09/2009 <br /> Facility Contact Person: MGR-SUE LYNN <br /> Make/Model of Monitoring System:VR TLS350 Work Order Number: 2263513 <br /> B.Inventory of Equipment Tested/Certified <br /> Check the appropriate boxes to indicate specific equipment inspected/serviced <br /> Tank ID: 91 Tank ID: 87#1 <br /> X In-Tank Gauging Probe. Model: MAG X In-Tank Gauging Probe. Model: MAG <br /> X Annular Space or Vault Sensor. Model: 407 Annular Space or Vault Sensor. Model: 407 <br /> X Piping Sump/Trench Sensor(s). Model: 352 Piping Sump/Trench Sensor(s). Model: 352 <br /> X Fill Sump Sensor(s). Model: 208 208 <br /> Fill Sump Sensor(s). Model: <br /> Mechanical Line Leak Detector. Model: Mechanical Line Leak Detector. Model: <br /> 71 <br /> Electronic Line Leak Detector. Model: VR PLLD X Electronic Line Leak Detector. Model: VR PLLD <br /> X Tank Overfill/High-Level Sensor. Model: FLAPPER Tank Overfill/High-Level Sensor. Model: FLAPPER <br /> Other(specify equipment type and model in Section E on page 2). Other(specify equipment type and model in Section E on page 2). <br /> TanklD: 87#2 TanklD: <br /> 71 In-Tank Gauging Probe. Model: MAG In-Tank Gauging Probe. Model: <br /> X Annular Space or Vault Sensor. Model: 407 Annular Space or Vault Sensor. Model: <br /> X Piping Sumpffrench Sensor(s). Model: 352 Piping Sumpfrrench Sensor(s). Model: <br /> X Fill Sump Sensogs). Model: 208 Fill Sump Sensor(s). Model: <br /> Mechanical Line Leak Detector. Model: Mechanical Line Leak Detector. Model: <br /> X Electronic Line Leak Detector. Model: VR PLLD <br /> Electronic Line Leak Detector. Model: <br /> Tank Overfill/High-Level Sensor. Model: FLAPPER Tank Overfill/High-Level Sensor. Model: <br /> Other(specify equipment type and model in Section E on page 2). Other(specify equipment type and model in Section E on page 2). <br /> Dispenser : 1/2 Dispenser ID: 7/8 <br /> ®Dispenser Containment Sensor(s) Model 208 X Dispenser Containment Sensor(s) Model:208 <br /> X❑Shear Valve(s). FXJ Shear Valve(s) <br /> ❑Dispenser Containment Float(s)and Chain(s). Dispenser Containment Float(s)and Chain(s). <br /> Dispenser ID: 3/4 Dispenser ID: 9/10 <br /> 0 Dispenser Containment Sensor(s) Model:208 X Dispenser Containment Sensor(s). Model:208 <br /> X❑ Shear Valve(s). rXj Shear Valve(s). <br /> Dispenser Containment Float(s)and Chain(s). Dispenser Containment Float(s)and Chain(s). <br /> Dispenser ID: 5/6 Dispenser ID: 11/12 <br /> X❑ Dispenser Containment Sensor(s) Model:208 X-JI Dispenser Containment Sensor(s). Model:208 <br /> X❑ Shear Valve(s). X Shear Valve(s). <br /> 10 Dispenser Containment Float(s)and Chain(s). Dispenser Containment Float(s)and Chain(s). <br /> *If the facility contains more tanks or dispensers,copy this form.Include information for every tank and dispenser at the facility. <br /> C. Certification <br /> I certify that the equipment identified in this document was inspected/serviced in accordance with the manufacturers'guidelines. <br /> Attached to this certification is information(e.g manufacturers'checklists)necessary to verify that this information is correct. <br /> and a Site Plan showing the layout of monitoring equipment.For any equipment capable of generating such reports,I have also attached <br /> a copy of the(Check all that apply): System set-up X❑Alarm history report <br /> Technician Name(print): KENNETH LEE Signature: <br /> Certification No.: B36130 License.No.: 743160(Class'A'General Enginering Contractor License) <br /> Testing Company Name:Tanknology Phone No.: (800)800-4633 <br /> Site Address: 8501 N.MoPac Expressway,suite 400,Austin,TX 78759 Date of Testing/Servicing: 02/09/2009 <br /> Monitoring System Certification Page 1 of 3 Based on CA form dated 03/01 <br />