COMPLIANCE INFO_2007-2009
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
P
>
PACIFIC
>
6633
>
2300 - Underground Storage Tank Program
>
PR0231784
>
COMPLIANCE INFO_2007-2009
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/4/2023 3:43:47 PM
Creation date
6/23/2020 6:52:05 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2007-2009
RECORD_ID
PR0231784
PE
2361
FACILITY_ID
FA0003834
FACILITY_NAME
PACIFIC AVE CHEVRON
STREET_NUMBER
6633
STREET_NAME
PACIFIC
STREET_TYPE
AVE
City
STOCKTON
Zip
95207
APN
097-410-48
CURRENT_STATUS
01
SITE_LOCATION
6633 PACIFIC AVE
P_LOCATION
99
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231784_6633 PACIFIC_2007-2009.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
377
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SWRCB,January 2002 0 Page 6. <br /> 7. UNDER-DISPENSER CONTAINMENT (UDC) TESTING <br /> Test Method Developed By: ❑ UDC Manufacturer F-1 Industry Standard 1fl Professional Engineer <br /> El Other (Spec) <br /> Test Method Used: ❑ Pressure Vacuum ❑x Hydrostatic <br /> 11 Other (Specify) <br /> Test Equipment Used: vplt Equipment Resolution: <br /> uDc# 9/10 UDC# 11/12 UDC# UDC# <br /> UDC Manufacturer: c.s c.s <br /> UDC Material: fiberglass fiberglass <br /> UDC Depth: 3211 32" <br /> Height from UDC Top to Top of 1511 1511 <br /> Highest Piping Pentration: <br /> Height from UDCTop to Lowest 8„ 811 <br /> Electrical Pentration: <br /> Condition of UDC prior to testing: good good <br /> Portion of UDC Tested: 1 1711 1711 <br /> Does turbine shut down when <br /> sump sensor detects liquid(both X❑Yes❑No[:]N MYes❑No[:]N ❑Yes❑No[:]N []Yes❑No[:]N <br /> product and water)?* <br /> Turbine shutdown response time: 2-5 secs 2-5 sec s <br /> Is system programmed for fail-safe ❑ � ❑ � [::]Yes❑ <br /> shutdown?* Yes N N X❑Yes N N N N Yes No <br /> Was fail-safe verified to be ❑ ❑ _]NA❑ ❑ ❑ ❑ ❑ ❑ <br /> operational?* X Yes N X Yes N N X Yes N N Yes No <br /> Wait time between applying <br /> pressure/vacuum/water and starting 5 min 5 min <br /> test: <br /> Test Start Time: 12:07 12:06 <br /> Initial Reading(Ri): 7.494 2.563 <br /> Test End Time: 12:22 12 :21 <br /> Final Reading(RF): 7.401 2.521 <br /> Test Duration: 15 mint 15 min <br /> Change in Reading(RF-RI ): .011gph .005gph <br /> Pass/Fail Threshold or Criteria: 05gph .05gph <br /> MEN= <br /> Was sensor removed for testing? % Yes N NA % Yes N NA Yes N NA 0Yes No <br /> Was sensor properly replaced and � � ❑ � ❑ ❑ �V <br /> verified functional after testing? X❑Ye N�NA Ye N NA Ye N NA Yes N <br /> Comments- (include information on repairs made prior to testing, and recommended follow-up for failed tests) <br /> starting and ending value—s— are taken off t e vp t <br /> 1 If the entire depth of the UDC is not tested,specify how much was tested.If the answer toanv of the questions indicated with an <br /> asterisk(*)is"NO"or"NA",the entire UDC must be tested. (See SWRCB LG-160) <br />