Laserfiche WebLink
�C�wg.'+a• a r+=v��/n—��,-r-i.x±..-, r'-t ''z-.�'-c�r t• "�,kt;.�.a�� _ ,. '�"'�`2�t� <br /> S ►TE OF CALIFORN WATER RESOURCES CONT ' <br /> OARD Hf <br /> FORM 'B': UND GROUND STORAGE TANK PR RAM <br /> TANK TANK PERMIT APPLICATION INFORMATION "� <br /> COMPLETE A SEPARATE FORM WITH THE FOLLOWING INFORMATION FOR EACH TANK. <br /> C1lIP0 N P <br /> MARK ONLY ❑ 1 NEW PERMIT ❑ 3 RENEWAL PERMITHANGE OF INFORMATION F-17 PERMANENTLY CLOSED TANK <br /> ONE ITEM ❑2 INTERIM PERMIT ❑4 AMENDED PERMIT ❑6 TEMPORARY TANK CLOSURE 8 TANK REMOVED <br /> FACILITY/SITE NAME WHERE TANK IS INSTALLED: FARM TANK-YES NO , <br /> I. TANK.DESCRIPTION COMPLETE ALL ITEMS-IF UNKNOWN—SO SPECIFY 1v3 <br /> A. OWNERS TANK ID# U B. MANUFACTURED BY: <br /> C. YEAR INSTALLED D. TANK CAPACITY IN GALLONS: 1515- L <br /> II. TANK CONTENTS IF(A.1),IS MARKED,COMPLETE ITEM C.IF(A.1),IS NOT MARKED,COMPLETE ITEM D. -4 <br /> A. ❑ 1 MOTOR VEHICLE FUEL ❑ 2 PET EUM B. C. ❑ 1 UNLEADED ❑ 2 LEADED ❑ 3 DIESEL <br /> ❑ 3 CHEMICAL PRODUCT OIL ❑ 1 PRODUCT ❑ 4 GASAHOL ❑ 5 JET FUEL ❑ 6 AVIATION GAS <br /> 5 HAZARDOUS 80 EMPTY ❑ 95 UNKNOWN ASTE ❑ 7 METHANOLTHER(DESCRIBE IN ITEM D,BELOW) <br /> D. IF NOT MOTOR VEHICLE FUEL,ENTER NAME OF <br /> HAZARDOUS SUBSTANCE STORED&C.A.S.# �� ., C.A.S.#: � " <br /> xIII. TANK CONSTRUCTION MARK ONE ITEM ONLY IN BOX A,B,C,&D <br /> A.TYPE OF ❑ 1 DOUBLE WALLED ❑ 3 SINGLE WALLED WITH EXTERIOR LINER NKNOWN <br /> SYSTEM 2 SINGLE WALLED 4 SECONDARY CONTAINMENT 99 OTHER <br /> F-] 1 STEEL/IRON ❑ 2 STAINLESS STEEL F—] 3 FIBERGLASS ❑4 STEEL CLAD W/FIBERGLASS REINFORCED PLASTIC <br /> B.TANK ❑ 5 CONCRETE ❑6 POLYVINYL CHLORIDE ❑ 7 ALUMI M ❑8 100%METHANOL COMPATIBLE FRP <br /> MATERIAL <br /> ❑ 9 BRONZE 10 GALVANIZED STEEL UNKNOWN ❑99 OTHER <br /> ❑ 1 RUBBER LINED ❑ 2 ALKYD LINING ❑ 3 EPDXY LINING ❑4 PHENO LINING <br /> C.INTERIOR <br /> LINING ❑ 5 GLASS LINING ❑6 UNLINED UNKNOWN <br /> ❑ IS LINING MATERIAL COMPATIBLE WITH 100%METHANOL? ❑YES ❑ NO ❑99 OTHER <br /> D.CORROSION ❑ 1 POLYETHLENE WRAP ❑2 TAR OR ASPHALTU;5 <br /> VINY AP E]4 FIBERGLASS REINFORCED PLASTIC <br /> PROTECTION ❑ 5 CATHODIC PROTECTION E]91 NONE UNKNOWN ❑99 OTHER <br /> IV. PIPING INFORMATION CIRCLE A IF ABOVE GROUND, U IF UNDERGROUND,BOTH IF APPLICABLE <br /> A.SYSTEM TYPE A U 1 SUCTION A U 2 PRESSURE A U 3 GRAVITY A U 99 OTHER 7,75(m' <br /> B.CONSTRUCTION A U 1 SINGLE WALLED A U 2 DOUBLE WALLED A U 3 LINED TRENCH A 5 UNKNOWN A U 99 OTHER <br /> A U 1 STEEL/IRON A U 2 STAINLESS STEEL A U 3 POLYVINYL CHLORIDE(PVC) A U 4 FIBERGLASS PIPE <br /> C. MATERIAL A U 5 ALUMINUM A U 6 CONCRETE A U 7 STEEL CLAD W/FRP A U 8 100%METHANOL COMPATIBLE FRP <br /> A U 9 GALVANIZED STEEL A UNKNOWN A U 99 OTHER <br /> V. LEAK DETECTION SYSTEM CIRCLE P FOR PRIMARY,OR S FOR SECONDARY,A PRIMARY LEAK DETECTION SYSTEM MUST BE CIRCLED. <br /> n 1 P S I VISUAL CHECK P S 2 INVENTORY RECONCILIATION P S 3 VADOSE WELLS P S 4 ELECTRONIC MONITOR P S 5 GROUND WATER MONITORING WELLS <br /> P S 6 PRECISION TESTING P S 7 PRESSURE TESTING P S 91 NONE S 95 NKNOWN P S 99 OTHER <br /> VI. INFORMATION ON TANK PERMANENTLY CLOSED IN PLACE <br /> 1. ESTIMATED DATE LAST USED(MO/YR) 2. ESTIMATED QUANTITY OF 3.WAS TANK FILLED WITH <br /> X GALLONS <br /> SUBSTANCE REMAINING IN INERT MATERIAL? ❑YES ONO <br /> �V <br /> THIS FORM HAS BEEN COMPLETED UNDER PENALTY OF PERJURY,AND TO THE BEST OF MY KNOWLEDGE,IS TRUE AND CORRECT. <br /> APPLICANT'S NAME(PRINTED&SIGNATURE) DATE <br /> LOCAL AGENCY USE ONLY <br /> COUNTY# JURISDICTION# AGENCY# FACILITY ID# TANK ID# <br /> EEI �l r lg> I D 010 1ER <br /> CURRENTLOCAL AGENCY FACILITY ID# APPROVED BY VAjM�" PHONE#WITH AREA CODE <br /> OL\l � / U O <br /> PERMIT NUMBER PERMIT APPROVAL DATE P RMIT EXPI TION DATE <br /> CHECK# PERMIT AMOUNT SURCHARGE AMT. FEE CODERECEIPT# BY: <br /> FORM B(3-7-88) THIS FORM MUST BE ACCOMPANIED Y A FACILITY/SITE APPLICATION, FORM 'A',UNLESS RENT FORM'A' HAS BEEN FILED <br /> DATA PROCESSING COPY <br />