My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_1987-1992
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
C
>
CHRISMAN
>
34243
>
2300 - Underground Storage Tank Program
>
PR0231801
>
COMPLIANCE INFO_1987-1992
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/8/2022 4:37:59 PM
Creation date
6/23/2020 6:52:31 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1987-1992
RECORD_ID
PR0231801
PE
2361
FACILITY_ID
FA0003290
FACILITY_NAME
COUNTRY MART GAS & FOOD
STREET_NUMBER
34243
Direction
S
STREET_NAME
CHRISMAN
STREET_TYPE
RD
City
TRACY
Zip
95304-9334
APN
25318004
CURRENT_STATUS
01
SITE_LOCATION
34243 S CHRISMAN RD
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231801_34243 S CHRISMAN_1989.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
247
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Overfill <br />The Problem <br />Whether you call it overfill, overspill <br />or something else, the problem is <br />creating headaches for all of us. <br />It can happen because of <br />inaccurate sticking of the tank, <br />dropping the wrong compartment <br />or filling the wrong tank. Regardless <br />of the cause, what it means is the <br />tank is filled beyond its capacity. <br />After a truck compartment has <br />been unloaded, as much as 10 to <br />20 gallons of gasoline may remain <br />trapped in the delivery hose. If <br />there is no room in the tank, the <br />contents of the hose could spill <br />onto the driveway or into the fill <br />manhole when the hose is <br />uncoupled. <br />Hydrocarbons can and do <br />pollute. They saturate the ground <br />and can even leach into ground- <br />water supplies. <br />Warranty <br />All Emco Wheaton products are <br />warranted free from defects in <br />material and workmanship under <br />normal use and service for a period <br />of twelve (12) months from the date <br />of manufacture. <br />THE WARRANTY SET FORTH <br />HEREIN SHALL BE THE EXCLUSIVE <br />WARRANTY MADE BY EMCO <br />WHEATON AND IN LIEU OF ALL <br />OTHER WARRANTIES, EXPRESS OR <br />IMPLIED, (WHETHER WRITTEN OR <br />ORAL), INCLUDING BUT NOT <br />LIMITED TO ANY IMPLIED WAR- <br />RANTY OF MERCHANTABILITY OR <br />FITNESS FOR ANY PARTICULAR <br />PURPOSE. <br />2 <br />Legislators are aware of the <br />problem and are studying ways to <br />correct it. They probably won't go <br />after the transport driver — <br />negligence is hard to prove — but <br />they could come after you. <br />Legal precedent holds the <br />property owner responsible for what <br />happens on his land. Station <br />owners could be held responsible <br />for overfills at their locations, and be <br />forced to pay the cost of cleaning <br />them up. <br />Emco Wheaton has several ways <br />to protect against overfill. Your best <br />bet for worry -free overfill protection <br />is our new AUTOMATIC OVERFILL <br />PREVENTION SYSTEM. It works like <br />an automatic nozzle on your fill <br />pipe and shuts -off product flow at a <br />safe, predetermined level. <br />Emco Wheaton's liability under this <br />warranty is limited to, at Emco <br />Wheaton's option, the repair or <br />replacement of that part which <br />proves to be defective within twelve <br />(12) months of date of manufacture. <br />Emco Wheaton is not responsible for <br />claims for damage due to improper <br />installation or maintenance, corrosive <br />fluids, or use of a product fora <br />purpose other than it was specificaily <br />designed for. <br />Emco Wheaton shall have no <br />liability or be required to fulfill any <br />obligation under this warranty unless <br />the original purchaser permits Emco <br />Wheaton to inspect the item to <br />determine whether the claimed <br />defect is covered by this warranty <br />and returns the claimed defective <br />item to Emco Wheaton's factory at <br />Conneaut, Ohio with all transportation <br />charges to said factory prepaid. <br />0 <br />If you choose to use more <br />traditional methods of overfill <br />protection, Emco Wheaton has <br />something for you. A new <br />CONTAINMENT MANHOLE made <br />of aluminum and gas -resistant <br />plastic has some radical design <br />features that make it the best <br />available on the market. Emco <br />Wheaton also offers FLOAT VALVES <br />and COAXIAL DROP TUBES that <br />can reduce the risk of costly <br />product spills. <br />These Emco Wheaton products <br />are described on the following <br />pages. Should you have additional <br />questions, contact your nearest <br />distributor, or call the factory direct <br />at (800) 321-5233. <br />We feel that your business <br />interests and the environment are <br />worth protecting. <br />UNDER NO CIRCUMSTANCES <br />SHALL EMCO WHEATON BE LIABLE <br />FOR ANY CONSEQUENTIAL, <br />SPECIAL OR CONTINGENT <br />DAMAGES OR EXPENSES OR ANY <br />OTHER CHARGES BEYOND THE <br />INVOICE VALUE OF THE DEFECTIVE <br />ITEMS. THE REMEDIES SET FORTH <br />HEREIN SHALL BE THE EXCLUSIVE <br />REMEDIES AVAILABLE TO THE <br />USER AND ARE IN LIEU OF ALL <br />OTHER REMEDIES. <br />© Copyright 1986 Emco Wheaton, • <br />Inc. All rights reserved. <br />