Laserfiche WebLink
IN-TANK SETUP <br /> SYSTEM SETUP - - - - - - - - - - - - <br /> - - - - - - - - - - - - <br /> APR 13, 2011 9:26 AM T I :UNLEADED <br /> PRODUCT CODE I <br /> THERMAL COEFF :..000700 <br /> SYSTEM UNITS, TANK DIAMETER. 111 .50 <br /> U.S. TANK PROFILE 20 PTS <br /> FULL VOL 12062 <br /> SYSTEM LANGUAGE 105.9 INCH VOL 11785 <br /> ENGLISH 100.3 INCH VOL 11411 <br /> SYSTEM DATE/TIME FORMAT 94.8 INCH VOL 10856 <br /> MON DD YYYY HH:MM:SS xM 89.2 INCH VOL 10328 <br /> 83.6 INCH VOL 9634 <br /> COUNTRY MART 78.0 INCH VOL 9017 <br /> 34243 S. CHRISMAN RD 72.5 INCH VOL 8241 <br /> TRACY CA 95376 66.9 INCH VOL 7439 <br /> 209-832-8642 61 .3 INCH VOL 6756 <br /> COMMUNICATIONS' SETUP 55.7 INCH VOL 5931 <br /> SHIFT TIME I DISABLED - - - - - - - - - - - 50.2 INCH VOL 5243 <br /> SHIFT TIME 2 DISABLED 44.6 INCH VOL 4427 <br /> SHIFT TIME 3 DISABLED 39.0 INCH VOL 3761 <br /> SHIFT TIME 4 DISABLED PORT SETTINGS: 33.4 INCH VOL 2988 <br /> 27.9 INCH VOL 2255 <br /> TANK PER TST NEEDED WRN COMM BOARD 1 (RS-232) 22.3 INCH VOL 1685 <br /> DISABLED BAUD RATE 9600 16.7 INCH VOL 1064 <br /> TANK ANN TST NEEDED WRN PARITY ODD 11 .1 -INCH VOL 616 <br /> DISABLED STOP BIT I STOP 5.6 INCH VOL 192 <br /> DATAILENGTH: 7 DATA <br /> LINE RE-ENABLE METHOD RS-232 SECURITY <br /> PASS LINE TEST CODE : DISABLED FLOAT SIZE: 4.0 IN. <br /> LINE PER TST NEEDED WRN COMM BOARD : 3 (EDIM WATER WARNING 2.0 <br /> DISABLED RS-232 SECURITY HIGH WATER LIMIT: 3.0 <br /> LINE ANN TST NEEDED WRN CODE : DISABLED <br /> DISABLED MAX OR LABEL VOL: 12062 <br /> OVERFILL LIMIT 900 <br /> PRINT TC VOLUMES AUTO TRANSMIT SETTINGS: 10855 <br /> ENABLED HIGH PRODUCT 95% <br /> AUTO LEAK ALARM LIMIT 11459 <br /> TEMP COMPENSATION DISABLED DELIVERY LIMIT 20% <br /> VALUE (DEG F is 60.0 AUTO HIGH WATER LIMIT 2412 <br /> STICK HEIGHT OFFSET DISABLED <br /> DISABLED AUTO OVERFILL LIMIT LOW PRODUCT 1000 <br /> DISABLED LEAK ALARM LIMIT: 99 <br /> H-PROTOCOL DATA FORMAT AUTO LOW PRODUCT SUDDEN LOSS LIMIT: 99 <br /> HEIGHT DISABLED TANK TILT <br /> 4.00 <br /> DAYLIGHT SAVING TIME AUTO THEFT LIMIT PROBE OFFSET 0.00 <br /> ENABLED DISABLED <br /> START DATE AUTO DELIVERY START <br /> APR WEEK I SUN DISABLED SIPHON MANIFOLDED TANKS <br /> START TIME AUTO DELIVERY END T#: NONE <br /> 2:00 AM DISABLED LINE MANIFOLDED TANKS <br /> END DATE AUTO EXTERNAL INPUT ON T#: NO'NE <br /> OCT WEEK 2 SUN DISABLED <br /> END TIME AUTO EXTERNAL INPUT OFF <br /> 2:00 AM DISABLED LEAK MIN PERIODIC: 0% <br /> AUTO SENSOR FUEL ALARM 0 <br /> RE-DIRECT LOCAL PRINTOUT DISABLED <br /> DISABLED AUTO SENSOR WATER ALARM LEAK MIN ANNUAL 0% <br /> DISABLED 0 <br /> EURO PROTOCOL PREFIX AUTO SENSOR OUT ALARM <br /> S DISABLED <br /> PERIODIC TEST TYPE <br /> STANDARD <br /> SYSTEM SECURITY ,ANNUAL TEST FAIL <br /> CODE : 000000 ALARM DISABLED <br /> PERIODIC TEST FAIL <br /> TANK CHART SECURITY ALARM DISABLED <br /> DISABLED RS-232 END OF MESSAGE <br /> DISABLED GROSS TEST FAIL <br /> CUSTOM ALARMS ALARM DISABLED <br /> DISABLED ANN TEST AVERAGING: OFF <br /> PER TEST AVERAGING: OFF <br /> MASS/DENSITY TANK TEST NOTIFY: OFF <br /> DISABLED <br /> TNK TST SIPHON BREAK:OFF <br /> DELIVERY DELAY I MIN <br /> tivL,T-(ztv Siff---r secur PUMP THRESHOLD 10.00% <br />