My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2007-2011
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
C
>
CHRISMAN
>
34243
>
2300 - Underground Storage Tank Program
>
PR0231801
>
COMPLIANCE INFO_2007-2011
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/9/2022 9:10:07 AM
Creation date
6/23/2020 6:52:47 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2007-2011
RECORD_ID
PR0231801
PE
2361
FACILITY_ID
FA0003290
FACILITY_NAME
COUNTRY MART GAS & FOOD
STREET_NUMBER
34243
Direction
S
STREET_NAME
CHRISMAN
STREET_TYPE
RD
City
TRACY
Zip
95304-9334
APN
25318004
CURRENT_STATUS
01
SITE_LOCATION
34243 S CHRISMAN RD
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231801_34243 S CHRISMAN_2007-2011.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
525
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
LEAK TEST METHOD <br /> — — — — — — — — — — — — OUTPUT RELAY SETUP <br /> TEST ON DATE : TANK I — — — — — — — — — — — — <br /> DEC 2, 2008 <br /> START TIME : 8:15 PM R I :UNLEADED' <br /> TEST RATE :0.10 GAL/HR TYPE: <br /> DURATION 3 HOURS STANDARD <br /> L 8:DISP 11 SAT NORMALLY CLOSED <br /> TST EARLY STOP:ENABLED TRI—STATE (SINGLE FLOAT) <br /> CATEGORY : DISPENSER PAN TANK #: 1 <br /> TEST ON DATE : TANK 2 <br /> SEP 5, 2007 LIQUID SENSOR ALMS <br /> START TIME : DISABLED L 9:DISP 11-12 L 4:FUEL ALARM <br /> TEST RATE :0.10 GAL/HR TRI—STATE (SINGLE FLOAT) L13:FUEL -ALARM <br /> DURATION 3 HOURS CATEGORY : DISPENSER PAN L14:FUEL ALARM <br /> L15:FUEL ALARM <br /> TST EARLY STOP:ENABLED L16:FUEL ALARM <br /> L 4:SENS0R OUT ALARM <br /> LIO:DISP 12 5-13 M L13:SENS0R OUT ALARM <br /> TEST ON DATE : TANK 3 TRI—STATE (SINGLE FLOAT) L14:SENS0R OUT ALARM <br /> SEP 16, 2007 CATEGORY : DISPENSER PAN L15:SENS0R OUT ALARM <br /> START TIME : 10:30 AM L16:SENSOR OUT ALARM <br /> TEST RATE :0.10 GAL/HR L 4:SHORT ALARM <br /> DURATION 3 HOURS L13:SH0RT ALARM <br /> LII :DISp 13-14 L14:SHORT ALARM <br /> TST EARLY STOP:ENABLED TRI—STATE (SINGLE FLOAT) L15:SH0RT ALARM <br /> CATEGORY : DISPENSER PAN, L16:SH0RT ALARM <br /> TEST ON DATE : TANK 4 ISD SITE ALARMS. <br /> SEP 19, 2007 ISD GROSS PRES FAIL <br /> START TIME : 11 :00 PM L12:DISP 9-10 ISD DEGRD PRES FAIL <br /> TEST RATE :0. 10 GAL/HR TRI—STATE (SINGLE FLOAT) ISD VAPOR LEAK FAIL <br /> DURATION 3 HOURS CATEGORY : DISPENSER PAN ISD VP PRES FAIL <br /> ISD SETUP FAIL <br /> TST EARLY STOP:ENABLED ISD SENSOR OUT FAIL <br /> LEAK TEST REPORT FORMAT L13:DISP 1-2 ISD HOSE ALARMS <br /> ENHANCED TRI—STATE (SINGLE FLOAT) ALL:GROSS COLLECT FAIL <br /> CATEGORY : DISPENSER PAN ALL;DEGRD COLLECT FAIL <br /> LIQUID SENSOR SETUP ALL:FLOW COLLECT FAIL <br /> — — — — — — — — — — — — <br /> R 2:SUPER <br /> L I :UNL ANN L14:DISP 3-4 TYPE: <br /> TRI—STATE (SINGLE FLOAT) TRI—STATE (SINGLE FLOAT) STANDARD <br /> CATEGORY : ANNULAR SPACE CATEGORY : DISPENSER PAN NORMALLY CLOSED <br /> TANK #: 2 <br /> L 2:SUP—DSL I ANN L15:DISP 5-6 <br /> TRI—STATE (SINGLE FLOAT) TRI—STATE (SINGLE FLOAT) LIQUID SENSOR ALMS <br /> CATEGORY : ANNULAR SPACE CATEGORY : DISPENSER PAN L 5:FUEL ALARM <br /> L13:FOEL ALARM <br /> L14:FUEL ALARM <br /> L15:FUEL ALARM <br /> L 3:DSL 2 ANN L16:DISP 7-8 L16:FUEL ALARM <br /> TRI—STATE (SINGLE FLOAT) TRI—STATE (SINGLE FLOAT) L 5:SENS0R OUT ALARM <br /> CATEGORY : ANNULAR SPACE CATEGORY DISPENSER PAN L13:SENS0R OUT ALARM <br /> L14:SENSOR OUT ALARM <br /> L15:SENSOR OUT ALARM <br /> L16:SENS0R OUT ALARM <br /> L 4:UNL STP L 5:SH0RT ALARM <br /> TRI—STATE (SINGLE FLOAT) L13:SHORT ALARM <br /> CATEGORY : STP SUMP L14:SHORT ALARM <br /> L15:SHORT ALARM <br /> L 5:SUP STP aI-16:SHORT ALARM <br /> TRI—STATE (SINGLE FLOAT) ISD SITE ALARMS <br /> CATEGORY : STP SUMP ISD GROSS PRES FAIL <br /> ISD DEGRD PRES FAIL <br /> ISD VAPOR LEAK FAIL <br /> L 6:DSL I STP ISD VP PRES FAIL <br /> TRI—STATE (SINGLE FLOAT) ISD SETUP FAIL <br /> CATEGORY STP SUMP ISD SENSOR OUT FAIL <br /> ISD HOSE ALARMS <br /> L 7:DSL 2 STP ALL:GROSS COLLECT FAIL <br /> TRI—STATE (SINGLE FLOAT) ALL:DEGRD COLLECT FAIL <br /> CATEGORY STP SUMP ALL:FLOW COLLECT FAIL <br />
The URL can be used to link to this page
Your browser does not support the video tag.