Laserfiche WebLink
MONIPORING <br />For Use By All Jurisdictions Within the State of California <br />Authority Cited: Chapter 6.7, Health and Safety Code, Chapter 16, Division 3, Title 23, California Code of Regulations <br />This form must be used to document testing and servicing of monitoring equipment. A separate certification or report must be prepared <br />for each monitoring system control panel by the technician who performs the work. A copy of this form must be provided to the tank <br />system owner/operator. The owner/operator must submit a copy of this form to the local agency regulating UST systems within 30 <br />days of test date. <br />A. General Information <br />Facility Name: Unified Western Grocers <br />Site Address: 1990 Piccoli Street city: Stockton <br />Facility Contact Person: Pat GuillernletV <br />Make/Model of Monitoring System: Veeder-Root TLS 350 <br />B. Inventory of Equipment Tested/Ce ° ied <br />( Check the appropriate boxes to indicate specific equipment inspected/serviced: <br />I I . 0 1 0 1 , 6 0 11 <br />Date of Testing/Servicing: 12/3/2009 <br />Tank ID: T 1— Diesel <br />Tank ID: T 2 — Diesel <br />M In -Tank Gauging Probe. <br />Model: 847390-107 <br />❑ In -Tank Gauging Probe. <br />Model: <br />® Annular Space or Vault Sensor. <br />Model: 794390420 <br />❑ Annular Space or Vault Sensor. <br />Model: <br />® Piping Sump / Trench Sensor(s). <br />Model: 794380-208 <br />❑ Piping Sump / Trench Sensor(s). <br />Model: <br />❑ Fill Sump Sensor(s). <br />Model: <br />❑ Fill Sump Sensor(s). <br />Model: <br />® Mechanical Line Leak Detector. <br />Model: FE Petro <br />❑ Mechanical Line Leak Detector. <br />Model: <br />❑ Electronic Line Leak Detector. <br />Model: <br />❑ Electronic Line Leak Detector. <br />Model: <br />❑ Tank Overfill / High -Level Sensor. <br />Model: <br />❑ Tank Overfill / High -Level Sensor. <br />Model: <br />❑ Other(specify equipment a and model in Section E on P e 2). <br />❑ Other (specify equipment type and model in Section E on Page 2). <br />Tank ID: T 3 — Waste Oil <br />Tank ID: <br />❑ In -Tank Gauging Probe. <br />Model: <br />❑ In -Tank Gauging Probe. <br />Model: <br />❑ Annular Space or Vault Sensor. <br />Model: <br />❑ Annular Space or Vault Sensor. <br />Model: <br />❑ Piping Sump / Trench Sensor(s). <br />Model: <br />❑ Piping Sump / Trench Sensor(s). <br />Model: <br />❑ Fill Sump Sensor(s). <br />Model: <br />❑ Fill Sump Sensor(s). <br />Model: <br />❑ Mechanical Line Leak Detector. <br />Model: <br />❑ Mechanical Line Leak Detector. <br />Model: <br />❑ Electronic Line Leak Detector. <br />Model: <br />❑ Electronic Line Leak Detector. <br />Model: <br />❑ Tank Overfill / High -Level Sensor. <br />Model: <br />❑ Tank Overfill / High -Level Sensor. <br />Model: <br />❑ Other(specify a ui ment a and model in Section E on P e 2). <br />❑ Other (specify equipment type and model in Section E on Page 2). <br />Dispenser ID: Dispenser 01 <br />Dispenser ID: <br />® Dispenser Containment Sensor(s). <br />Model: 794380-420 <br />❑ Dispenser Containment Sensor(s). <br />Model: <br />® Shear Valve(s). <br />Ll Shear Valve(s). <br />L3Dis enser Containment Float(s) and Chain s). <br />❑Dispenser Containment Float(s) and <br />Chain(s). <br />Dispenser ID: <br />Dispenser ID: <br />❑ Dispenser Containment Sensor(s). <br />Model: <br />❑ Dispenser Containment Sensor(s). <br />Model: <br />❑ Shear Valve(s). <br />❑ Shear Valve(s). <br />❑Dis enser Containment Float(s) and <br />Chain(s). <br />❑ Dispenser Containment Float s) and Chain(s). <br />Dispenser ID: <br />Dispenser : <br />❑ Dispenser Containment Sensor(s). <br />Model: <br />❑ Dispenser Containment Sensor(s). <br />Model: <br />❑ Shear Valve(s). <br />❑ Shear Valve(s). <br />❑Dis enser Containment Floats and Chains . <br />❑ Dispenser Containment Floats and Chain(s). <br />*If the facility contains more tanks or dispensers, copy this form. Include information for every tank and dispenser at the facility. <br />C. Ce °kation - I certify that the equipment identified in this document was inspected/serviced in accordance with the manufacturers' <br />guidelines. Attached to this Certification is information (e.g. manufacturers' ch klists) necessary to verify that this information is <br />correct and a Plot Plan showing the layout of monitoring equipment. For any equi ent capable of generating such reports, I have also <br />attached a copy of the report; (check all that apply): ® System set-up I hist report <br />Technician Name (print): Asa Cosby Signature: <br />Certification No.: A-22350 <br />Testing Company Name: A & J Environmental Svc's Inc. <br />Site Address: 1990 Piccoli Street Stockton Ca 95215 <br />License. No.: A - <br />Phone No.:(9091 <br />Date of Testing/Servicing: 12/32009 <br />Page 1 of 3 03/01 <br />